Thermal performance of buildings integrated with phase change materials to reduce heat stress risks during extreme heatwave events
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Although PCM application can mitigate overheating during power outages, its resiliency is highly correlated to temporal factors (initiation time and duration of a power outage), PCM properties, and climate.
“They found that although PCM application can mitigate overheating during power outages, its resiliency is highly correlated to temporal factors (initiation time and duration of a power outage), PCM properties, and climate.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [173]
In most cases, there is no significant added resiliency advantage by using PCMs because energy efficiency is the main driver of their installation.
“Considering the fact that energy efficiency is the main driver of the installation of PCMs, in most cases, there is no significant added resiliency advantage by using PCMs [173].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [173]
PCM melt temperature is a crucial factor in determining its resiliency.
“They stated that the PCM melt temperature is a crucial factor in determining its resiliency.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [173]
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · see citing works
Sage-Lauck, J. S., & Sailor, D. J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.028 · Cited by 166 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhang, L., Zhou, K., Wei, Q., Ma, L., Ye, W., Li, H., Zhou, B., Yu, Z., Lin, C.-T., Luo, J., et al. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.10.036 · Cited by 282 · see citing works
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180 · see citing works
Wang, T., Jiang, Y., Huang, J., & Wang, S. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.108 · Cited by 69 · see citing works
- Authors
- Ramakrishnan, S., Wang, X., Sanjayan, J., & Wilson, J.
- Affiliations
- Swinburne University of Technology (AU)
- CSIRO Land and Water (AU)
- Corresponding author
- Ramakrishnan, Sayanthan
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 194
- Pages
- 410-421
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2340998931
- Cited by
- 241
- References
- 2
- Citations by year
- 2026: 16 · 2025: 15 · 2024: 21 · 2023: 25 · 2022: 27 · 2021: 27 · 2020: 26 · 2019: 35 · 2018: 34 · 2017: 15
- FWCI
- 24.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Swinburne figshare (Swinburne University of Technology) (submittedVersion)
- Funders
- CSIRO Climate Adaptation Flagship
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- phase change materials, building renovation, heat stress, heat waves, indoor thermal comfort, thermal energy storage, night ventilation, bio-based phase change materials, one-story houses, occupant health, Melbourne
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review