Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 376

The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.

Sorption heat storage for long-term low-temperature applications: A review on the advancements at material and prototype scale

Open access
Scapino, Luca, Zondag, Herbert A., Van Bael, Johan, Diriken, Jan, Rindt, Camilo C.M.·2017·Applied Energy

Abstract

Sorption heat storage has the potential to store large amounts of thermal energy from renewables and other distributed energy sources. This article provides an overview on the recent advancements on long-term sorption heat storage at material- and prototype- scales. The focus is on applications requiring heat within a temperature range of 30–150 °C such as space heating, domestic hot water production, and some industrial processes. At material level, emphasis is put on solid/gas reactions with water as sorbate. In particular, salt hydrates, adsorbents, and recent advancements on composite materials are reviewed. Most of the investigated salt hydrates comply with requirements such as safety and availability at low cost. However, hydrothermal stability issues such as deliquescence and decomposition at certain operating conditions make their utilization in a pure form challenging. Adsorbents are more hydrothermally stable but have lower energy densities and higher prices. Composite materials are investigated to reduce hydrothermal instabilities while achieving acceptable energy densities and material costs. At prototype-scale, the article provides an updated review on system prototypes based on the reviewed materials. Both open and closed system layouts are addressed, together with the main design issues such as heat and mass transfer in the reactors and materials corrosion resistance. Especially for open systems, the focus is on pure adsorbents rather than salt hydrates as active materials due to their better stability. However, high material costs and desorption temperatures, coupled with lower energy densities at typical system operating conditions, decrease their commercial attractiveness. Among the main conclusions, the implementation within the scientific community of common key performance indicators is suggested together with the inclusion of economic aspects already at material-scale investigations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2016.12.148

Cites

70 of 70 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 70 references

Cited by

See all 376

Metadata

Authors
Scapino, L., Zondag, H. A., Van Bael, J., Diriken, J., & Rindt, C. C. M.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2017-03
Volume
190
Pages
920-948
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2572330938
Cited by
376
References
70
FWCI
29.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sorption heat storage for long-term low-temperature applications: A review on the advancements at material and prototype scale. https://app.cochat.ai/papers/10.1016/j.apenergy.2016.12.148
The paper
Scapino, L., Zondag, H. A., Van Bael, J., Diriken, J., & Rindt, C. C. M. (2017). Sorption heat storage for long-term low-temperature applications: A review on the advancements at material and prototype scale. Applied Energy. https://doi.org/10.1016/j.apenergy.2016.12.148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.