Advances in seasonal thermal energy storage for solar district heating applications: A critical review on large-scale hot-water tank and pit thermal energy storage systems
Abstract
Nowadays, buildings consume a large amount of conventional energy sources in European countries and subsequently they contribute significantly to fossil fuels emissions. Therefore, many European countries have introduced several policies to minimize this consumption by transitioning buildings into more energy efficient ones, whereas some other policies focus on integrating renewables into energy systems. In this context, solar district heating is one of the promising technologies that reduces the use of fossils and, thereby, leads to fewer CO2 emissions. The main drawback of solar energy, however, is that it fluctuates on daily and seasonal basis in which the highest heat availability is in summer, while the highest demand is in winter. Hence, a seasonal thermal energy storage (STES) is required to bridge the temporal mismatch between renewable energy availability and buildings’ demand. Accordingly, this study reviews briefly the different seasonal thermal energy storage technologies that are feasible for district heating applications. Then, the paper focuses chiefly on large-scale hot water TES (tanks and pits). Construction (geometry and envelope), modeling and design of these TES systems are the primary focus. Next, system performance indicators are also reviewed. A synopsis of the current TES systems is eventually presented as well. The literature review reveals: (1) Tank TES (TTES) and pit TES (PTES) are less subjected to hydro- geological conditions than aquifer TES (ATES) and borehole TES (BTES), (2) TTES and PTES require high construction cost compared to ATES and BTES, (3) TTES and PTES provide higher charging/discharging power than ATES and BTES due to higher operational temperature difference and flowrates, (4) in hot water TES, as the depth decreases, the more the stratification tends to degrade and, therefore, tanks are preferable over pits, (5) no established co-simulation platform between TES envelope and surroundings coupled to energy analysis models and (6) no effective approach or measure has been found to evaluate one TES to another.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy storage systems—Characteristics and comparisons
IBRAHIM, H., ILINCA, A., & PERRON, J. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.01.023 · Cited by 2,331
Contrasting the capabilities of building energy performance simulation programs
Crawley, D. B., Hand, J. W., Kummert, M., & Griffith, B. T. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.10.027 · Cited by 1,858
An overview of thermal energy storage systems
Alva, G., Lin, Y., & Fang, G. (2018) · Energy · doi:10.1016/j.energy.2017.12.037 · Cited by 1,408
Ground-source heat pumps systems and applications
Omer, A. M. (2006) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2006.10.003 · Cited by 819
General review of ground-source heat pump systems for heating and cooling of buildings
Sârbu, I., & Sebarchievici, C. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.11.068 · Cited by 716
Phase change materials and thermal energy storage for buildings
de Gracia, A., & Cabeza, L. F. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.06.007 · Cited by 688
A review of available technologies for seasonal thermal energy storage
Xu, J., Wang, R. Z., & Li, Y. (2014) · Solar Energy · doi:10.1016/j.solener.2013.06.006 · Cited by 659
The Functional Mockup Interface for Tool independent Exchange of Simulation Models
Blochwitz, T., Otter, M., Arnold, M., Bausch, C., Clauss, C., Elmqvist, H., Junghanns, A., Mauss, J., Monteiro, M., Neidhold, T., et al. (2011) · Linköping Electronic Conference Proceedings · doi:10.3384/ecp11063105 · Cited by 590
Matos, C. R., Carneiro, J. F., & Silva, P. P. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.023 · Cited by 560
Pinel, P., Cruickshank, C. A., Beausoleil-Morrison, I., & Wills, A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.04.013 · Cited by 536
Cited by
Energy storage systems: a review
Mitali, J., Dhinakaran, S., & Mohamad, A. A. (2022) · Energy Storage and Saving · doi:10.1016/j.enss.2022.07.002 · Cited by 911
Latent thermal energy storage technologies and applications: A review
Jouhara, H., Żabnieńska-Góra, A., Khordehgah, N., Ahmad, D., & Lipinski, T. (2020) · International Journal of Thermofluids · doi:10.1016/j.ijft.2020.100039 · Cited by 543
“[91], can be classified into three main types:”
BackgroundMethodNižetić, S., Djilali, N., Papadopoulos, A., & Rodrigues, J. J. P. C. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.04.397 · Cited by 538
Dynamic model of solar heating plant with seasonal thermal energy storage
Kubiński, K., & Szabłowski, Ł. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.07.120 · Cited by 52
Metadata
- Authors
- Dahash, A., Ochs, F., Janetti, M. B., & Streicher, W.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 239
- Pages
- 296-315
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2911252948
- Cited by
- 364
- References
- 46
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in seasonal thermal energy storage for solar district heating applications: A critical review on large-scale hot-water tank and pit thermal energy storage systems. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.01.189
- The paper
- Dahash, A., Ochs, F., Janetti, M. B., & Streicher, W. (2019). Advances in seasonal thermal energy storage for solar district heating applications: A critical review on large-scale hot-water tank and pit thermal energy storage systems. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.01.189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.