Effects of particle sizes and tilt angles on dust deposition characteristics of a ground-mounted solar photovoltaic system
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The dust deposition behaviours of ground-mounted solar photovoltaic (PV) panels and their effects on the PV efficiency were numerically investigated. The shear stress transport k-ω turbulence model with the inlet user-defined function profiles and the discrete particle model were used to predict the wind flow fields and the dust deposition rates of a PV panel. A grid independence study was conducted, and the mean pressure coefficient was validated with the related experimental data. The effects of the different dust particle diameters and the different tilt angles of the PV panels on the dust deposition characteristics were investigated carefully. The results showed the dust deposition rates of a PV panel were considerably affected by the different tilt angles. The dust deposition rates were considerably higher for the upward PV installations than for the downward ones. Moreover, the dust deposition rates were greater when the solar PV panel was more horizontal with the ground. The peak deposition rates were observed for the 150-μm dust particles for all of the tilted PV panel angles. The maximum deposition rates were 14.28%, 13.53%, 6.79% and 9.78% for the tilted PV panel angles of 25°, 40°, 140° and 155°, respectively. Moreover, the main deposition mechanisms of the solar PV panel were analysed and discussed for the different dust particle sizes and PV panel installation angles. Finally, an empirical model was developed for estimating the PV output reductions caused by the dust deposition for different tilt angles, which could be applied in practical engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,360
Two-equation eddy-viscosity turbulence models for engineering applications
Menter, F. R. (1994) · AIAA Journal · doi:10.2514/3.12149 · Cited by 21,593
Numerical Heat Transfer and Fluid Flow
Hsu, C.-J. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,125
Connolly, D., Lund, H., Mathiesen, B. V., & Leahy, M. (2010) · Applied Energy · doi:10.1016/j.apenergy.2009.09.026 · Cited by 1,631
Mani, M., & Pillai, R. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.07.065 · Cited by 1,130
Sarver, T., Al-Qaraghuli, A., & Kazmerski, L. L. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.12.065 · Cited by 969
Ventilation performance prediction for buildings: A method overview and recent applications
Chen, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.05.025 · Cited by 957
Optimal design and techno-economic analysis of a hybrid solar–wind power generation system
Yang, H., Wei, Z., & Lou, C. (2008) · Applied Energy · doi:10.1016/j.apenergy.2008.03.008 · Cited by 794
Energy yield loss caused by dust deposition on photovoltaic panels
Sayyah, A., Horenstein, M. N., & Mazumder, M. K. (2014) · Solar Energy · doi:10.1016/j.solener.2014.05.030 · Cited by 646
Sharma, V., & Chandel, S. S. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.07.046 · Cited by 620
Effect of dust on the transparent cover of solar collectors
Elminir, H. K., Ghitas, A., Hamid, R. H., El-Hussainy, F. M., Beheary, M. M., & Abdel-Moneim, K. M. (2006) · Energy Conversion and Management · doi:10.1016/j.enconman.2006.02.014 · Cited by 609
Effect of dust accumulation on the power outputs of solar photovoltaic modules
Adinoyi, M. J., & Said, S. A. M. (2013) · Renewable Energy · doi:10.1016/j.renene.2013.06.014 · Cited by 522
Particle deposition in turbulent duct flows—comparisons of different model predictions
Tian, L., & Ahmadi, G. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2006.12.003 · Cited by 399
Effect of dust with different physical properties on the performance of photovoltaic cells
El-Shobokshy, M. S., & Hussein, F. M. (1993) · Solar Energy · doi:10.1016/0038-092x(93)90135-b · Cited by 364
Dust as an unalterable deteriorative factor affecting PV panel's efficiency: Why and how
Zaihidee, F. M., Mekhilef, S., Seyedmahmoudian, M., & Horan, B. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.068 · Cited by 323
Kaldellis, J. K., & Kapsali, M. (2011) · Energy · doi:10.1016/j.energy.2011.06.018 · Cited by 303
Goossens, D., & Kerschaever, E. V. (1999) · Solar Energy · doi:10.1016/s0038-092x(99)00028-6 · Cited by 300
Marzband, M., Ghadimi, M., Sumper, A., & Domínguez-García, J. L. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.056 · Cited by 245
Dust-induced shading on photovoltaic modules
Qasem, H., Betts, T. R., Müllejans, H., AlBusairi, H., & Gottschalg, R. (2014) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.2230 · Cited by 241
Tominaga, Y., Akabayashi, S.-I., Kitahara, T., & Arinami, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.11.012 · Cited by 239
Understanding the effects of sand and dust accumulation on photovoltaic modules
Beattie, N. S., Moir, R. S., Chacko, C., Buffoni, G., Roberts, S. H., & Pearsall, N. M. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.06.007 · Cited by 195
Prediction of particle deposition onto indoor surfaces by CFD with a modified Lagrangian method
Zhang, Z., & Chen, Q. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.041 · Cited by 180
Effect of soiling in CPV systems
Vivar, M., Herrero, R., Antón, I., Martínez‐Moreno, F., Moretón, R., Sala, G., Blakers, A. W., & Smeltink, J. (2010) · Solar Energy · doi:10.1016/j.solener.2010.03.031 · Cited by 175
Fornarelli, F., Camporeale, S. M., Fortunato, B., Torresi, M., Oresta, P., Magliocchetti, L., Miliozzi, A., & Santo, G. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.11.106 · Cited by 164
Numerical simulation of wind effects on a stand-alone ground mounted photovoltaic (PV) system
Jubayer, C., & Hangan, H. M. (2014) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2014.08.008 · Cited by 156
Modeling particle deposition from fully developed turbulent flow in ventilation duct
Zhao, B., & Wu, J. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.09.043 · Cited by 152
Thermal energy storage strategies for effective closed greenhouse design
Vadiee, A., & Martin, V. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.12.065 · Cited by 147
Han, J., Lu, L., & Yang, H. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.05.025 · Cited by 135
Karava, P., Jubayer, C., & Savory, E. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.02.042 · Cited by 130
Gao, N., Niu, J., He, Q., Zhu, T., & Jia-zheng, W. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.09.003 · Cited by 115
Pavan, A. M., Mellit, A., Pieri, D. D., & Kalogirou, S. A. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.03.023 · Cited by 106
Dust effects on PV array performance: in‐field observations with non‐uniform patterns
Lorenzo, E., Moretón, R., & Luque, I. I. (2013) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.2348 · Cited by 106
Flow and heat transfer inside a PV/T collector for building application
Zogou, O., & Stapountzis, H. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.09.019 · Cited by 71
Effects of rib spacing and height on particle deposition in ribbed duct air flows
Lu, H., & Lu, L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.035 · Cited by 61
Self-citationCFD investigation on particle deposition in aligned and staggered ribbed duct air flows
Lu, H., & Lu, L. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.10.030 · Cited by 51
Self-citation
Metadata
- Authors
- Lu, H., & Zhao, W.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 220
- Pages
- 514-526
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2794817259
- Cited by
- 183
- References
- 35
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.