Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Quantitative evaluation method for the complementarity of wind–solar–hydro power and optimization of wind–solar ratio

Han, Shuang, Zhang, Lu-na, Liu, Yong-qian, Zhang, Hao, Yan, Jie, Li, Li, Lei, Xiao-hui, Wang, Xu · 2019 · Applied Energy

Abstract

Abstract Complementarity between wind power, photovoltaic, and hydropower is of great importance for the optimal planning and operation of a combined power system. However, less attention has been paid to quantify the level of complementarity of wind power, photovoltaic and hydropower. Therefore, this paper proposes a complementarity evaluation method for wind power, photovoltaic and hydropower by thoroughly examining the fluctuation of the independent and combined power generation. To begin with, a series of evaluation indices are presented from two perspectives: random fluctuation between adjacent time slots and ramp within continuous time windows. Secondly, a method for screening the typical meteorological day is proposed by combining t-distributed stochastic neighbor embedding with K-means clustering algorithm to improve the evaluation of daily complementarity. This method can deal with the feature extraction of high-dimension and correlated data sequences. A case study is conducted for the validation of the proposed method, and the evaluation result of the proposed method was compared with that of the Kendall’ rank correlation coefficient based on the Gaussian copula function. It is found that the proposed method has higher accuracy because it describes the complementarity from two aspects including fluctuation and ramp. It is also found from the study case that the optimum complementarity level for a certain case can be achieved by changing the ratio of photovoltaic and wind power. This work will provide reference for the optimization of power grid dispatch and power supply planning of combined power stations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2018.12.059

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Han, S., Zhang, L.-N., Liu, Y.-Q., Zhang, H., Yan, J., Li, L., Lei, X.-H., & Wang, X.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2019-02
Volume
236
Pages
973-984
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2904362481
Cited by
165
References
1
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative evaluation method for the complementarity of wind–solar–hydro power and optimization of wind–solar ratio. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.12.059
The paper
Han, S., Zhang, L.-N., Liu, Y.-Q., Zhang, H., Yan, J., Li, L., Lei, X.-H., & Wang, X. (2019). Quantitative evaluation method for the complementarity of wind–solar–hydro power and optimization of wind–solar ratio. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.12.059

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.