The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Optimal operational planning of scalable DC microgrid with demand response, islanding, and battery degradation cost considerations
Open accessAbstract
With the advancements in power electronic devices, the increasing use of DC loads, DC renewable generation sources and battery storage systems, and no reactive power and frequency stability issues, DC microgrids are increasingly gaining attention in both academia and industry. In this paper, a grid-connected DC microgrid is considered, which consists of a PV system and a Li-ion battery. DC microgrids optimal operation requires battery degradation cost modeling and demand response incentive for active consumers’ participation to be addressed in detail. Therefore, a practical degradation cost model for a Li-ion battery is developed to optimize battery scheduling and achieve its realistic operational cost. Apart from energy price, scheduled islanding responsive demand response incentive is also introduced to encourage customers to shift load during scheduled grid-tie line maintenance. Levelized cost of energy of PV system is calculated for both hot and cold climate regions. Optimal operation of DC microgrid cannot be achieved without considering nodal voltages and system losses. Hence, network constraints are also included in the proposed model. Extensive numerical simulations are carried out to prove the effectiveness of the proposed approach. The achieved results would aid in DC microgrids adoption planning that would expectedly replace traditional AC grids in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ageing mechanisms in lithium-ion batteries
Vetter, J., Novák, P., Wagner, M. R., Veit, C., Möller, K.-C., Besenhard, J. O., Winter, M., Wohlfahrt-Mehrens, M., Vogler, C., & Hammouche, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.01.006 · Cited by 3,987
Demand response and smart grids – a survey
Siano, P. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.10.022 · Cited by 2,411
Hybrid Optimization for Economic Deployment of ESS in PV-Integrated EV Charging Stations
Chaudhari, K., Ukil, A., Kumar, K. N., Manandhar, U., & Kollimalla, S. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2713481 · Cited by 384
Realistic lifetime prediction approach for Li-ion batteries
Sarasketa-Zabala, E., Martinez-Laserna, E., Berecibar, M., Gandiaga, I., Rodriguez-Martinez, L. M., & Villarreal, I. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.10.115 · Cited by 191
Cited by
Zia, M. F., Benbouzid, M., Elbouchikhi, E., Muyeen, S. M., Techato, K., & Guerrero, J. M. (2020) · IEEE Access · doi:10.1109/access.2020.2968402 · Cited by 355
Self-citationWali, S. B., Hannan, M. A., Reza, M. S., Ker, P. J., Begum, R. A., Rahman, M. S. A., & Mansor, M. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102296 · Cited by 149
Metadata
- Authors
- Zia, M. F., Elbouchikhi, E., & Benbouzid, M.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 237
- Pages
- 695-707
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2909174164
- Cited by
- 191
- References
- 4
- FWCI
- 13.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal operational planning of scalable DC microgrid with demand response, islanding, and battery degradation cost considerations. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.01.040
- The paper
- Zia, M. F., Elbouchikhi, E., & Benbouzid, M. (2019). Optimal operational planning of scalable DC microgrid with demand response, islanding, and battery degradation cost considerations. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.01.040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.