Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record.

Smart energy management algorithm for load smoothing and peak shaving based on load forecasting of an island’s power system

Open access
Chapaloglou, Spyridon, Nesiadis, Athanasios, Iliadis, Petros, Atsonios, Konstantinos, Nikolopoulos, Nikos, Grammelis, Panagiotis, Yiakopoulos, Christos, Antoniadis, Ioannis, Kakaras, Emmanuel·2019·Applied Energy

Abstract

Abstract In this study, a novel algorithm for the management of the power flows of an islanded power system was developed, capable of simultaneously achieving steadier conventional unit operation and shaving the demand peak values, for the days of the year that present a night peak in their load curve. The under investigation system is composed of Diesel Generators, a PV farm and a Battery Energy Storage System (BESS) with the power system’s consumption to be relatively higher than its RES production. The proposed algorithm combines the use of a load forecasting methodology, a pattern recognition procedure and a custom optimal power flow scheduling algorithm. The prediction module was based on a feedforward artificial neural network, capable of short-term day ahead load forecasting. The forecasted day ahead load profile was then used as an input to the developed pattern recognition algorithm, in order to be classified based on its load curve shape (pattern). Subsequently, in case that the classification resulted in a clear night peak pattern, it was possible to estimate an hourly based trajectory for the diesel generators operation and derive the BESS charging setpoints, which result in the desired peak shaving and smoothing level simultaneously. In this way, it is possible to replace or substitute the highest power demand with stored renewable energy and to operate the diesel engines as steady as possible, diminishing the ramp up and the steep gradients before the night hours’ peak. The algorithm was integrated in the overall system model in APROS software, where dynamic simulations were performed. The simulation results proved that by applying the proposed algorithm, a combined effect of smoother diesel generator operation and peak shaving with renewable energy is achievable even with the absence of PV overproduction, diminishing the variability of the load to be covered from the conventional units. Such an operation aims at enabling diesel engines to be rated at a lower, than currently, maximum capacity while increasing the share of the renewable energy penetration into the grid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2019.01.102

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Chapaloglou, S., Nesiadis, A., Iliadis, P., Atsonios, K., Nikolopoulos, N., Grammelis, P., Yiakopoulos, C., Antoniadis, I., & Kakaras, E.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2019-03
Volume
238
Pages
627-642
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2911933099
Cited by
167
References
0
FWCI
7.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Smart energy management algorithm for load smoothing and peak shaving based on load forecasting of an island’s power system. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.01.102
The paper
Chapaloglou, S., Nesiadis, A., Iliadis, P., Atsonios, K., Nikolopoulos, N., Grammelis, P., Yiakopoulos, C., Antoniadis, I., & Kakaras, E. (2019). Smart energy management algorithm for load smoothing and peak shaving based on load forecasting of an island’s power system. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.01.102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.