Combined decentralized and local voltage control strategy of soft open points in active distribution networks
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract With the integration of high shares of distributed generators (DGs), it is increasingly difficult to cope with the voltage violations and puts forward a higher requirement for the operational flexibility in active distribution networks (ADNs). Soft open point (SOP) can realize accurate power flow control and continuous voltage regulation, which is usually operated by the centralized control strategy. However, the heavy burden of communication and complex global optimization process hinder its application on fast voltage control. This paper proposes a combined decentralized and local voltage control strategy of SOPs to rapidly cope with the frequent voltage fluctuations. Based on the dynamic network partition results, the decentralized optimization is applied to regulate active power transmission of SOPs among the connected areas. The Q - V control curve is optimally tuned to locally regulate the reactive power outputs of SOPs by using the intra-area information. Compared to the widely-used centralized strategy, the proposed combined control strategy of SOPs can effectively reduce the communication and computational burden with acceptable voltage control performance. Finally, the effectiveness of the proposed control strategy of SOPs is validated on the modified PG&E 69-node distribution system and modified IEEE 123-node distribution system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Cited by
Local flexibility markets: Literature review on concepts, models and clearing methods
Jin, X., Wu, Q., & Jia, H. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114387 · Cited by 373
An Overview of Soft Open Points in Electricity Distribution Networks
Jiang, X., Zhou, Y., Ming, W., Yang, P., & Wu, J. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3148599 · Cited by 278
Self-citationMa, W., Wang, W., Chen, Z., & Hu, R. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.106852 · Cited by 44
Data-driven combined central and distributed volt/var control in active distribution networks
Sun, X., Qiu, J., Tao, Y., & Zhao, J. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3213587 · Cited by 42
“Compared with the original formulation (1)-(10), the reformulated optimization model {(1)-(8a), (11)-(13)} is a mixed-integer second-order cone program (MISOCP) that can be efficiently solved with off-the-shelf solvers [19].”
MethodSelf-citationPrabawa, P., & Choi, D.-H. (2021) · IEEE Access · doi:10.1109/access.2021.3109621 · Cited by 31
Metadata
- Authors
- Li, P., Ji, H., Yu, H., Zhao, J., Wang, C., Song, G., & Wu, J.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 241
- Pages
- 613-624
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2921672886
- Cited by
- 111
- References
- 3
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.