Using separate cooling coils for sensible and latent loads provide extra control flexibility to optimise the energy efficiency and comfort in air-conditioning and mechanical ventilation (ACMV) systems. A popular implementation of such technology is dedicated outdoor air system (DOAS)-assisted separate sensible and latent cooling (SSLC) systems. However, a sophisticated control technique is needed to coordinate the control of multiple cooling coils in such systems. This paper presents a novel model predictive control (MPC) developed for a DOAS-assisted SSLC system. The MPC adopts a linear state-space model that captures building thermodynamics, thermal comfort and ACMV for building response prediction and optimization. Subsequently, a multi-objective cost function is employed to optimize energy use and thermal comfort while fulfilling constraints of predicted mean vote (PMV) (-0.5, 0.5) and relative humidity (0%, 65%) in buildings. The performance of the MPC for controlling a conventional single-coil air-handling unit (AHU) system and a DOAS-assisted SSLC system is experimentally investigated and compared to a conventional feedback-control-based building management system (BMS). The MPC system achieved 18% and 20% electricity savings for the single-coil AHU and DOAS-assisted SSLC, respectively, as compared to the BMS controlled single-coil AHU. Furthermore, indoor thermal comfort is significantly improved, compared to the BMS. DOAS-assisted SSLC is shown to be advantageous compared to single-coil AHU to achieve better indoor environment in terms of thermal comfort and humidity, when both systems are controlled by MPC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Examples include actuator smoothness, fallback behavior, stability margins, and resilience under uncertainty [108,109,119].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [109]
In the citing paper
“Most real-life studies evaluated thermal comfort deviation, PMV, TCI, or CO 2 -based IAQ as explicit metrics [109,117,156,166].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [109]
In the citing paper
“Metrics such as energy savings, cost savings, and energy efficiency improvement, remained the principal indicators of economic and environmental value [108,109,117,119,120].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [109]
In the citing paper
“Hot-humid climates: Such as Singapore, Abu Dhabi, Zhejiang, Shenzhen, and parts of the USA account for 30% of cases [98,99,109,113,122,123].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [109]
In the citing paper
“The most common settings concern experimental real-world testbeds as academic and laboratory testbeds, including university offices, lecture rooms, and living-labs [109,111,114,131,141]”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [109]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization (ISO)
Nahler, G. (2009) · Dictionary of Pharmaceutical Medicine · doi:10.1007/978-3-211-89836-9_723 · Cited by 3,677
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
Achieving better energy-efficient air conditioning – A review of technologies and strategies
Chua, K. J., Chou, S. K., Yang, W. M., & Yan, J. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.10.037 · Cited by 949
Shaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866
Experimental analysis of model predictive control for an energy efficient building heating system
Široký, J., Oldewurtel, F., Cigler, J., & Prívara, S. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.03.009 · Cited by 753
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Model Predictive Control for the Operation of Building Cooling Systems
Ma, Y., Borrelli, F., Hencey, B., Coffey, B., Bengea, S., & Haves, P. (2012) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2011.2124461 · Cited by 527
Approximate model predictive building control via machine learning
Drgoňa, J., Picard, D., Kvasnica, M., & Helsen, L. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.156 · Cited by 260
Hazyuk, I., Ghiaus, C., & Penhouet, D. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.11.009 · Cited by 242
Ascione, F., Bianco, N., De Stasio, C., Mauro, G. M., & Vanoli, G. P. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.033 · Cited by 235
Cited by
Items 101–101 of 101
Li, Y., Li, W., Wang, J., Tu, R., & Song, H. (2026) · Energies · doi:10.3390/en19225581
Metadata
- Authors
- Yang, S., Wan, M. P., Ng, B. F., Dubey, S., Henze, G. P., Chen, W., & Baskaran, K.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 257
- Pages
- 113920
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2982281067
- Cited by
- 91
- References
- 40
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.