Building thermal load prediction through shallow machine learning and deep learning
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Abstract Building thermal load prediction informs the optimization of cooling plant and thermal energy storage. Physics-based prediction models of building thermal load are constrained by the model and input complexity. In this study, we developed 12 data-driven models (7 shallow learning, 2 deep learning, and 3 heuristic methods) to predict building thermal load and compared shallow machine learning and deep learning. The 12 prediction models were compared with the measured cooling demand. It was found XGBoost (Extreme Gradient Boost) and LSTM (Long Short Term Memory) provided the most accurate load prediction in the shallow and deep learning category, and both outperformed the best baseline model, which uses the previous day’s data for prediction. Then, we discussed how the prediction horizon and input uncertainty would influence the load prediction accuracy. Major conclusions are twofold: first, LSTM performs well in short-term prediction (1 h ahead) but not in long term prediction (24 h ahead), because the sequential information becomes less relevant and accordingly not so useful when the prediction horizon is long. Second, the presence of weather forecast uncertainty deteriorates XGBoost’s accuracy and favors LSTM, because the sequential information makes the model more robust to input uncertainty. Training the model with the uncertain rather than accurate weather data could enhance the model’s robustness. Our findings have two implications for practice. First, LSTM is recommended for short-term load prediction given that weather forecast uncertainty is unavoidable. Second, XGBoost is recommended for long term prediction, and the model should be trained with the presence of input uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
XGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining · doi:10.1145/2939672.2939785 · Cited by 54,569
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
An Analysis of Variance Test for Normality (Complete Samples)
Shapiro, S. S., & Wilk, M. B. (1965) · Biometrika · doi:10.2307/2333709 · Cited by 23,469
Asymptotic Theory of Certain "Goodness of Fit" Criteria Based on Stochastic Processes
Anderson, T. W., & Darling, D. A. (1952) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729437 · Cited by 3,542 · cited 1×
“We used three commonly used statistical test approaches to verify the null hypothesis that the prediction error follows Gaussian distribution: the Shapiro–Wilk test [36], D'Agostino's K-squared test [37], and the Anderson–Darling test [38].”
MethodA review on the prediction of building energy consumption
Zhao, H.-X., & Magoulès, F. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.049 · Cited by 1,937
A review of data-driven building energy consumption prediction studies
Amasyali, K., & El-Gohary, N. M. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.095 · Cited by 1,874
Chollet, F. (2017) · Cited by 1,158
Heating and cooling energy trends and drivers in buildings
Ürge-Vorsatz, D., Cabeza, L. F., Serrano, S., Barreneche, C., & Petrichenko, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.039 · Cited by 1,089
A short-term building cooling load prediction method using deep learning algorithms
Fan, C., Xiao, F., & Zhao, Y. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.03.064 · Cited by 692
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Fan, C., Xiao, F., & Wang, S. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.016 · Cited by 565
Applying support vector machine to predict hourly cooling load in the building
Li, Q., Meng, Q., Cai, J., Yoshino, H., & Mochida, A. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.11.035 · Cited by 485
Modeling heating and cooling loads by artificial intelligence for energy-efficient building design
Chou, J.-S., & Bui, D.-K. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.036 · Cited by 429
Predicting future hourly residential electrical consumption: A machine learning case study
Edwards, R. E., New, J., & Parker, L. E. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.03.010 · Cited by 391
Transformation to Normality of the Null Distribution of g 1
D'Agostino, R. B. (1970) · Biometrika · doi:10.2307/2334794 · Cited by 387
Transformation to normality of the null distribution of g1
D'AGOSTINO, R. B. (1970) · Biometrika · doi:10.1093/biomet/57.3.679 · Cited by 351
An Inverse Gray-Box Model for Transient Building Load Prediction
Braun, J. E., & Chaturvedi, N. (2002) · HVAC&R Research · doi:10.1080/10789669.2002.10391290 · Cited by 328
Wang, S., & Xu, X. (2006) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2005.06.009 · Cited by 308
Short-term load forecasting in a non-residential building contrasting models and attributes
Massana, J., Pous, C., Burgas, L., Melendez, J., & Colomer, J. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.007 · Cited by 211
Guo, Y., Wang, J., Chen, H., Li, G., Liu, J., Xu, C., Huang, R., & Huang, Y. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.03.125 · Cited by 207
Harb, H., Boyanov, N., Hernandez, L., Streblow, R., & Müller, D. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.02.021 · Cited by 198
EKF based self-adaptive thermal model for a passive house
Fux, S. F., Ashouri, A., Benz, M. J., & Guzzella, L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2012.06.016 · Cited by 194
An interactive building power demand management strategy for facilitating smart grid optimization
Xue, X., Wang, S., Sun, Y., & Xiao, F. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.11.064 · Cited by 188
Review of energy conservation technologies for fresh air supply in zero energy buildings
Liu, Z., Li, W., Chen, Y., Luo, Y., & Zhang, L. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.11.085 · Cited by 180
Pedersen, L., Stang, J., & Ulseth, R. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.10.014 · Cited by 166
The building performance gap: Are modellers literate?
Imam, S., Coley, D., & Walker, I. O. (2017) · Building Services Engineering Research and Technology · doi:10.1177/0143624416684641 · Cited by 157
Wei, Y., Xia, L., Pan, S., Wu, J., Zhang, X., Han, M., Zhang, W., Xie, J., & Li, Q. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.056 · Cited by 148
Hou, Z., Lian, Z., Yao, Y., & Yuan, X. (2005) · Applied Energy · doi:10.1016/j.apenergy.2005.08.006 · Cited by 141
Blum, D. H., Arendt, K., Rivalin, L., Piette, M. A., Wetter, M., & Veje, C. T. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.11.093 · Cited by 132
Self-citationData fusion in predicting internal heat gains for office buildings through a deep learning approach
Wang, Z., Hong, T., & Piette, M. A. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.066 · Cited by 120
Self-citationParallel Support Vector Machines Applied to the Prediction of Multiple Buildings Energy Consumption
Zhao, H. X., & Magoulès, F. (2010) · Journal of Algorithms & Computational Technology · doi:10.1260/1748-3018.4.2.231 · Cited by 119
Cooling output optimization of an air handling unit
Kusiak, A., & Li, M. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.06.010 · Cited by 114
Wang, W., Hong, T., Xu, X., Chen, J., Liu, Z., & Xu, N. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.04.085 · Cited by 80
Self-citationModeling and measurement study on an intermittent heating system of a residence in Cambridgeshire
Wang, Z., Lin, B., & Zhu, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.05.014 · Cited by 63
Self-citationPredicting plug loads with occupant count data through a deep learning approach
Wang, Z., Hong, T., & Piette, M. A. (2019) · Energy · doi:10.1016/j.energy.2019.05.138 · Cited by 56
Self-citation
Cited by
Deep learning models for solar irradiance forecasting: A comprehensive review
Kumari, P., & Toshniwal, D. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.128566 · Cited by 445
Physical energy and data-driven models in building energy prediction: A review
Chen, Y., Guo, M., Chen, Z., Chen, Z., & Ji, Y. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.01.162 · Cited by 384
Khalil, M., McGough, A. S., Pourmirza, Z., Pazhoohesh, M., & Walker, S. (2022) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105287 · Cited by 299
Energy Forecasting: A Comprehensive Review of Techniques and Technologies
Mystakidis, A., Koukaras, P., Tsalikidis, N., Ioannidis, D., & Tjortjis, C. (2024) · Energies · doi:10.3390/en17071662 · Cited by 165
Zhang, C., Li, J., Zhao, Y., Li, T., Chen, Q., & Zhang, X. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110301 · Cited by 124
Metadata
- Authors
- Wang, Z., Hong, T., & Piette, M. A.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 263
- Pages
- 114683
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3008571545
- Cited by
- 503
- References
- 37
- FWCI
- 29.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.