The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Inverse Gray-Box Model for Transient Building Load Prediction
Abstract
Lower costs and improved performance of sensors, controllers, and networking is leading to the development of smart building features, such as continuous performance monitoring, automated diagnostics, and optimal supervisory control. For some of these applications, it is important to be able to predict transient cooling and heating requirements for the building using inverse models that are trained using on-site data. Existing inverse models for transient building loads range from purely empirical or “black-box” models to purely physical or “white-box” models. Generally, black-box (e.g., neural network) models require a significant amount of training data and may not always reflect the actual physical behavior, whereas white-box (e.g., finite difference) models require specification of many physical parameters. This paper presents a hybrid or “gray-box” modeling approach that uses a transfer function with parameters that are constrained to satisfy a simple physical representation for energy flows in the building structure. A robust method is also presented for training parameters of the constrained model, wherein initial values of and bounds on physical parameters are estimated from a rough building description, better estimates are obtained using a global direct search algorithm, and optimal parameters are identified using a nonlinear regression algorithm. The model and training method were extensively tested for different buildings and locations using data generated from a detailed simulation program. The approach was also tested using data from a field site located near Chicago, Illinois. It was found that one to two weeks of data are sufficient to train a model so that it can accurately predict transient cooling or heating requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Cited by
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Physics-guided convolutional neural network (PhyCNN) for data-driven seismic response modeling
Zhang, R., Liu, Y., & Sun, H. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2020.110704 · Cited by 506
Building thermal load prediction through shallow machine learning and deep learning
Wang, Z., Hong, T., & Piette, M. A. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114683 · Cited by 503
Modeling techniques used in building HVAC control systems: A review
Afroz, Z., Shafiullah, G., Urmee, T., & Higgins, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.044 · Cited by 411
Grey-box modeling and application for building energy simulations - A critical review
Li, Y., O'Neill, Z., Zhang, L., Chen, J., Im, P., & DeGraw, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111174 · Cited by 359
Metadata
- Authors
- Braun, J. E., & Chaturvedi, N.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 8
- Issue
- 1
- Pages
- 73-99
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W2093447280
- Cited by
- 328
- References
- 1
- FWCI
- 23.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Inverse Gray-Box Model for Transient Building Load Prediction. https://app.cochat.ai/papers/10.1080/10789669.2002.10391290
- The paper
- Braun, J. E., & Chaturvedi, N. (2002). An Inverse Gray-Box Model for Transient Building Load Prediction. HVAC&R Research. https://doi.org/10.1080/10789669.2002.10391290
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.