Model predictive control with adaptive machine-learning-based model for building energy efficiency and comfort optimization
Abstract
A model predictive control system with adaptive machine-learning-based building models for building automation and control applications is proposed. The system features an adaptive machine-learning-based building dynamics modelling scheme that updates the building model regularly using online building operation data through a dynamic artificial neural network with a nonlinear autoregressive exogenous structure. The system also employs a multi-objective function that could optimize both energy efficiency and indoor thermal comfort, two often contradicting demands. The proposed model predictive control system is implemented to control the air-conditioning and mechanical ventilation systems in two single-zone testbeds, an office and a lecture theatre, located in Singapore for experimental evaluation of its control performance. The model predictive control system is compared against the original reactive control system (thermostat in the office and building management system in the lecture theatre) in each testbed. The model predictive control system reduces 58.5% cooling thermal energy consumption in the office and 36.7% cooling electricity consumption in the lecture theatre, as compared to their respective original control. Meanwhile, the indoor thermal comfort in both testbeds is also greatly improved by the model predictive control system. Developing a model predictive control system using machine-learning-based building dynamics models could largely cut down the model construction time to days as compared to its counterpart using physics-based models, which usually take months to construct. However, the machine-learning-based modelling approach could be challenged by lack of building operational data necessary for model training in case of model predictive control development before the building has become operational.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Thermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
Optimization by Direct Search: New Perspectives on Some Classical and Modern Methods
Kolda, T. G., Lewis, R. M., & Torczon, V. (2003) · SIAM Review · doi:10.1137/s003614450242889 · Cited by 1,653
Achieving better energy-efficient air conditioning – A review of technologies and strategies
Chua, K. J., Chou, S. K., Yang, W. M., & Yan, J. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.10.037 · Cited by 949
Shaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866
Experimental analysis of model predictive control for an energy efficient building heating system
Široký, J., Oldewurtel, F., Cigler, J., & Prívara, S. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.03.009 · Cited by 753
Afram, A., Janabi-Sharifi, F., Fung, A. S., & Raahemifar, K. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.012 · Cited by 655
Asadi, E., Silva, M. G. D., Antunes, C. H., Dias, L., & Glicksman, L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.009 · Cited by 523
Neural networks based predictive control for thermal comfort and energy savings in public buildings
Ferreira, P. M., Ruano, A. E., Silva, S., & Conceição, E. Z. E. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.08.002 · Cited by 445
Cited by
Himeur, Y., Elnour, M., Fadli, F., Meskin, N., Petri, I., Rezgui, Y., Bensaali, F., & Amira, A. (2023) · Artificial Intelligence Review · doi:10.1007/s10462-022-10286-2 · Cited by 541
Yao, Y., & Shekhar, D. K. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107952 · Cited by 447
Tien, P. W., Wei, S., Darkwa, J., Wood, C., & Calautit, J. K. (2022) · Energy and AI · doi:10.1016/j.egyai.2022.100198 · Cited by 295
Aliramezani, M., Koch, C. R., & Shahbakhti, M. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2021.100967 · Cited by 288
Evaluation of advanced control strategies for building energy systems
Stoffel, P., Maier, L., Kümpel, A., Schreiber, T., & Müller, D. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112709 · Cited by 126
Metadata
- Authors
- Yang, S., Wan, M. P., Chen, W., Ng, B. F., & Dubey, S.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 271
- Pages
- 115147
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3031194307
- Cited by
- 403
- References
- 48
- FWCI
- 20.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model predictive control with adaptive machine-learning-based model for building energy efficiency and comfort optimization. https://app.cochat.ai/papers/10.1016/j.apenergy.2020.115147
- The paper
- Yang, S., Wan, M. P., Chen, W., Ng, B. F., & Dubey, S. (2020). Model predictive control with adaptive machine-learning-based model for building energy efficiency and comfort optimization. Applied Energy. https://doi.org/10.1016/j.apenergy.2020.115147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.