Energy savings in greenhouses by transition from high-pressure sodium to LED lighting
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Greenhouses in high latitudes consume vast amounts of energy for heating and supplemental lighting. Light emitting diodes (LEDs) have been suggested as having great potential for reducing greenhouse energy use, as they are extremely efficient at converting electricity to light. However, LEDs emit very little heat, which must be compensated by the greenhouse heating system. Thus, it is unclear how much energy can be saved by LEDs when the need for extra heating is taken into account. This study presents a first analysis of the energy demands for greenhouses transitioning from high-pressure sodium (HPS) to LED lighting, providing a quantification of the total energy savings achieved by LEDs. Model simulations using GreenLight, an open source greenhouse model, were used to examine a wide range of climates, from subtropical China to arctic Sweden, and multiple settings for indoor temperature, lamp intensity, lighting duration, and insulation. In most cases, the total energy saving by transition to LEDs was 10–25%. This value was linearly correlated with the fraction of energy used for lighting before the transition, which was 40–80%. In all scenarios, LEDs reduced the energy demand for lighting but increased the demand for heating. Since energy for lighting and heating is often derived from different origins, the benefits of a transition to LEDs depend on the environmental and financial costs of the available energy sources. The framework provided here can be used to select lighting installations that make optimal use of available energy resources in the most efficient and sustainable manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From physics to fixtures to food: current and potential LED efficacy
Kusuma, P., Pattison, P. M., & Bugbee, B. (2020) · Horticulture Research · doi:10.1038/s41438-020-0283-7 · Cited by 283
Cited by
Energy-saving design and control strategy towards modern sustainable greenhouse: A review
Zhang, M., Yan, T., Wang, W., Jia, X., Wang, J., & Klemeš, J. J. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112602 · Cited by 164
Pereira, J., & Gomes, M. G. (2025) · Applied Energy · doi:10.1016/j.apenergy.2024.124669 · Cited by 34
Metadata
- Authors
- Katzin, D., Marcelis, L. F. M., & van Mourik, S.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 281
- Pages
- 116019
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3097639645
- Cited by
- 168
- References
- 1
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy savings in greenhouses by transition from high-pressure sodium to LED lighting. https://app.cochat.ai/papers/10.1016/j.apenergy.2020.116019
- The paper
- Katzin, D., Marcelis, L. F. M., & van Mourik, S. (2021). Energy savings in greenhouses by transition from high-pressure sodium to LED lighting. Applied Energy. https://doi.org/10.1016/j.apenergy.2020.116019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.