Abstract
Abstract Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. The applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-level control through deep reinforcement learning
Mnih, V., Kavukcuoglu, K., Silver, D., Rusu, A. A., Veness, J., Bellemare, M. G., Graves, A., Riedmiller, M., Fidjeland, A. K., Ostrovski, G., et al. (2015) · Nature · doi:10.1038/nature14236 · Cited by 30,357
Mastering the game of Go with deep neural networks and tree search
Silver, D., Huang, A., Maddison, C. J., Guez, A., Sifre, L., van den Driessche, G., Schrittwieser, J., Antonoglou, I., Panneershelvam, V., Lanctot, M., et al. (2016) · Nature · doi:10.1038/nature16961 · Cited by 15,612
Continuous control with deep reinforcement learning
Lillicrap, T. P., Hunt, J. J., Pritzel, A., Heess, N., Erez, T., Tassa, Y., Silver, D., & Wierstra, D. (2015) · arXiv · doi:10.48550/arxiv.1509.02971 · Cited by 10,782
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
An Evaluation of the HVAC Load Potential for Providing Load Balancing Service
Lu, N. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2183649 · Cited by 739
On-Line Building Energy Optimization Using Deep Reinforcement Learning
Mocanu, E., Mocanu, D. C., Nguyen, P. H., Liotta, A., Webber, M. E., Gibescu, M., & Slootweg, J. G. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2834219 · Cited by 649
Building operation and energy performance: Monitoring, analysis and optimisation toolkit
Costa, A., Keane, M. M., Torrens, J. I., & Corry, E. (2013) · Applied Energy · doi:10.1016/j.apenergy.2011.10.037 · Cited by 394
Du, Y., & Li, F. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2930299 · Cited by 393
Self-citationMulti-Agent Deep Reinforcement Learning for HVAC Control in Commercial Buildings
Yu, L., Sun, Y., Xu, Z., Shen, C., Yue, D., Jiang, T., & Guan, X. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3011739 · Cited by 353
Zhang, Z., Chong, A., Pan, Y., Zhang, C., & Lam, K. P. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.07.029 · Cited by 339
Wu, Y., Tan, H., Peng, J., Zhang, H., & He, H. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.04.021 · Cited by 332
Optimal energy management strategies for energy Internet via deep reinforcement learning approach
Hua, H., Qin, Y., Hao, C., & Cao, J. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.145 · Cited by 329
Transactive Control of Commercial Buildings for Demand Response
Hao, H., Corbin, C. D., Kalsi, K., & Pratt, R. G. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2559485 · Cited by 285
DeepComfort: Energy-Efficient Thermal Comfort Control in Buildings Via Reinforcement Learning
Gao, G., Li, J., & Wen, Y. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2992117 · Cited by 283
Han, X., He, H., Wu, J., Peng, J., & Li, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113708 · Cited by 269
A reinforcement learning framework for optimal operation and maintenance of power grids
Rocchetta, R., Bellani, L., Compare, M., Zio, E., & Patelli, E. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.03.027 · Cited by 226
Zou, Z., Yu, X., & Ergan, S. (2020) · Building and Environment · doi:10.1016/j.buildenv.2019.106535 · Cited by 188
Wang, Y., Velswamy, K., & Huang, B. (2017) · Processes · doi:10.3390/pr5030046 · Cited by 179
Kou, P., Liang, D., Wang, C., Wu, Z., & Gao, L. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114772 · Cited by 170
Claessens, B. J., Vrancx, P., & Ruelens, F. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2629450 · Cited by 154
Online Energy Management for a Sustainable Smart Home With an HVAC Load and Random Occupancy
Yu, L., Jiang, T., & Zou, Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2775209 · Cited by 153
Erdinc, O., Tascikaraoglu, A., Paterakis, N. G., Eren, Y., & Catalao, J. P. S. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2556619 · Cited by 138
Hierarchical Control of Residential HVAC Units for Primary Frequency Regulation
Wu, X., He, J., Xu, Y., Lu, J., Lü, N., & Wang, X. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2766880 · Cited by 137
Ahn, K. U., & Park, C. S. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1680234 · Cited by 121
Kou, X., Li, F. F., Dong, J., Starke, M. R., Munk, P. L., Xue, Y. S., Olama, M. M., & Zandi, H. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.2995923 · Cited by 111
Self-citationFrom AlphaGo to Power System AI: What Engineers Can Learn from Solving the Most Complex Board Game
Li, F. F., & Du, Y. (2018) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2017.2779554 · Cited by 89
Self-citationWei, T., Ren, S., & Zhu, Q. (2019) · IEEE Transactions on Sustainable Computing · doi:10.1109/tsusc.2019.2910533 · Cited by 61
Energy Management Considering Load Operations and Forecast Errors With Application to HVAC Systems
Ma, K., Hu, G., & Spanos, C. J. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2558319 · Cited by 46
Cited by
Strategies to save energy in the context of the energy crisis: a review
Farghali, M., Osman, A. I., Mohamed, I. M. A., Chen, Z., Chen, L., Ihara, I., Yap, P.-S., & Rooney, D. W. (2023) · Environmental Chemistry Letters · doi:10.1007/s10311-023-01591-5 · Cited by 682
An overview of machine learning applications for smart buildings
Alanne, K., & Sierla, S. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103445 · Cited by 280
Saleem, M., Shakir, M., Usman, M., Bajwa, M., Shabbir, N., Shams Ghahfarokhi, P., & Daniel, K. (2023) · Energies · doi:10.3390/en16124835 · Cited by 197
“This paper [42] proposes an energy-saving control approach for HVAC systems in commercial buildings using a hybrid model predictive control and artificial neural network.”
MethodReinforcement learning for HVAC control in intelligent buildings: A technical and conceptual review
Al Sayed, K., Boodi, A., Sadeghian Broujeny, R., & Beddiar, K. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110085 · Cited by 140
Adesanya, M. A., Obasekore, H., Rabiu, A., Na, W.-H., Ogunlowo, Q. O., Akpenpuun, T. D., Kim, M.-H., Kim, H.-T., Kang, B.-Y., & Lee, H.-W. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124126 · Cited by 72
Metadata
- Authors
- Du, Y., Zandi, H., Kotevska, O., Kurte, K., Munk, J., Amasyali, K., Mckee, E., & Li, F.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 281
- Pages
- 116117
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3095810316
- Cited by
- 268
- References
- 28
- FWCI
- 17.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.