Medical device development: The challenge for ergonomics
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
High quality, well-designed medical devices are necessary to provide safe and effective clinical care for patients as well as to ensure the health and safety of professional and lay device users. Capturing the user requirements of users and incorporating these into design is an essential component of this. The field of ergonomics has an opportunity to assist, not only with this area, but also to encourage a more general consideration of the user during medical device development. A review of the literature on methods for assessing user requirements in engineering and ergonomics found that little published work exists on the ergonomic aspects of medical device development. In particular there is little advice available to developers on which issues to consider during design and development or recommendations for good practice in terms of the methods and approaches needed to capture the full range of user requirements. The Multidisciplinary Assessment of Technology Centre for Health care (MATCH) is a research collaboration that is working in conjunction with industrial collaborators to apply ergonomics methods to real case study projects with the ultimate aim of producing an industry-focused guide to applying ergonomics principles in medical device development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing for usability: key principles and what designers think
Gould, J. D., & Lewis, C. (1985) · Communications of the ACM · doi:10.1145/3166.3170 · Cited by 2,066
Leape, L. L. (1994) · PubMed · Cited by 1,961
Leape, L. L. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03520230061039 · Cited by 1,425
Using usability heuristics to evaluate patient safety of medical devices
Zhang, J., Johnson, T. R., Patel, V. L., Paige, D. L., & Kubose, T. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00060-1 · Cited by 591 · cited 1×
“Zhang et al. (2003) describe their experience of using heuristic evaluation during the design and development of an infusion pump and discuss whether this method, developed for humancomputer interfaces, can be applied more broadly to medical device development.”
MethodFundamentals of ergonomics in theory and practice
Wilson, J. R. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(00)00034-x · Cited by 439 · cited 2×
“This is a topic which has been identified as a key challenge for ergonomics, as Wilson states, “consistency on the balance between professionalism and protection on the one hand, and growth and spread on the other, will be difficult to achieve, but vital” (Wilson, 2000).”
BackgroundThe Benefits of Using ISO 13407: Human Centred Design Process for Interactive Systems.
Bevan, N., Earthy, J., & Kurosu, M. (2001) · International Conference on Human-Computer Interaction · Cited by 282
Usability in the real world: assessing medical information technologies in patients’ homes
Kaufman, D. R., Patel, V. L., Hilliman, C., Morin, P. C., Pevzner, J., Weinstock, R. S., Goland, R., Shea, S., & Starren, J. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00056-x · Cited by 254 · cited 2×
“We identified two papers that report the use of CW for computer-based medical applications: a medical software program (Patel and Kaufman 1998) and a system for patients to monitor their health from within their homes (Kaufman et al., 2003).”
BackgroundMaking customer-centered design work for teams
Holtzblatt, K., & Beyer, H. (1993) · Communications of the ACM · doi:10.1145/163430.164050 · Cited by 238 · cited 4×
“resource constraints of engineering” ( Holtzblatt and Beyer, 1993 p.93 ) and may be an attractive”
BackgroundInfluentialAnalysis of demographic characteristics.
Jorm, C., & Strunin, L. (1994) · PubMed · Cited by 234
Human Failure: An Analysis of 2000 Incident Reports
Williamson, J. A., Webb, R. K., Sellen, A., Runciman, W. B., & Van Der Walt, J. H. (1993) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9302100534 · Cited by 232
Cited by
Money, A. G., Barnett, J., Kuljis, J., Craven, M. P., Martin, J. L., & Young, T. (2011) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-11-15 · Cited by 203
“Currently the two most important regulations for medical device developers are the European Commission (EC) Medical Device Directive 93/42/EEC [10] and the United States (US) Food and Drug Administration (FDA) regulations since medical devices must comply with these regulations in order to be sold throughout Europe an…”
BackgroundMethodSelf-citationBiomedical application of optical fibre sensors
Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S. (2018) · Journal of Optics · doi:10.1088/2040-8986/aac68d · Cited by 206
Nanocomposite hydrogels for biomedical applications
Huang, S., Hong, X., Zhao, M., Liu, N., Liu, H., Zhao, J., Shao, L., Xue, W., Zhang, H., Zhu, P., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10315 · Cited by 176
“Medical devices can be divided into Class I, II, and III according to the use risk of products from small to large.(173) The new drugs require rigorous clinical trials, and the transformation is much more”
BackgroundIntegrating the results of user research into medical device development: insights from a case study
Martin, J. L., & Barnett, J. (2012) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-12-74 · Cited by 64
“This literature describes the theory behind this approach [11]; how and when to conduct the work, and with what groups of people [2,3,12].”
BackgroundSelf-citationUsing Storytelling to Elicit Design Guidance for Medical Devices
Gausepohl, K., Winchester, W. W., Arthur, J. D., & Smith-Jackson, T. (2011) · Ergonomics in Design The Quarterly of Human Factors Applications · doi:10.1177/1064804611408017 · Cited by 13
Metadata
- Authors
- Martin, J. L., Norris, B. J., Murphy, E., & Crowe, J. A.
- Venue
- Applied Ergonomics
- Publisher
- Elsevier BV
- Published
- 2008-05
- Volume
- 39
- Issue
- 3
- Pages
- 271-283
- ISSN
- 0003-6870 (ISSN-L)
- OpenAlex
- W2013571165
- Cited by
- 214
- References
- 32
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical device development: The challenge for ergonomics. https://app.cochat.ai/papers/10.1016/j.apergo.2007.10.002
- The paper
- Martin, J. L., Norris, B. J., Murphy, E., & Crowe, J. A. (2008). Medical device development: The challenge for ergonomics. Applied Ergonomics. https://doi.org/10.1016/j.apergo.2007.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.