The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Biomedical application of optical fibre sensors
Open accessAbstract
Optical fibre sensors (OFS), as a result of their unique properties such as small size, no interference with electromagnetic radiation, high sensitivity and the ability to design multiplexed or distributed sensing systems, have found applications ranging from structural health monitoring to biomedical and point of care instrumentation. While the former represents the main commercial application for OFS, there is body of literature concerning the deployment of this versatile sensing platform in healthcare. This paper reviews the different types of OFS and their most recent applications in healthcare. It aims to help clinicians to better understand OFS technology and also provides an overview of the challenges involved in the deployment of developed technology in healthcare. Examples of the application of OFS in healthcare are discussed with particular emphasis on recently (2015–2017) published works to avoid replicating recent review papers. The majority of the work on the development of biomedical OFS stops at the laboratory stage and, with a few exceptions, is not explored in healthcare settings. OFSs have yet to fulfil their great potential in healthcare and methods of increasing the adoption of medical devices based on optical fibres are discussed. It is important to consider these factors early in the device development process for successful translation of the developed sensors to healthcare practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vahala, K. J. (2003) · Nature · doi:10.1038/nature01939 · Cited by 4,878
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Cited by
Optical biosensors: an exhaustive and comprehensive review
Chen, C., & Wang, J. (2020) · The Analyst · doi:10.1039/c9an01998g · Cited by 781
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 377
Fiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Optical fiber sensors for monitoring in critical care
Morgan, S. P., Canfarotta, F., Piletska, E. V., Grillo, F., Korposh, S., Liu, L., Hernandez, F. U., Correia, R., Norris, A., Sinha, R., et al. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856893 · Cited by 13
Self-citation
Metadata
- Authors
- Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S.
- Venue
- Journal of Optics
- Publisher
- IOP Publishing
- Published
- 2018-06-08
- Volume
- 20
- Issue
- 7
- Pages
- 073003
- ISSN
- 0150-536X (ISSN-L)
- 2040-8978
- 2040-8986
- OpenAlex
- W2803270587
- Cited by
- 206
- References
- 3
- FWCI
- 8.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomedical application of optical fibre sensors. https://app.cochat.ai/papers/10.1088/2040-8986/aac68d
- The paper
- Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S. (2018). Biomedical application of optical fibre sensors. Journal of Optics. https://doi.org/10.1088/2040-8986/aac68d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.