The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Assessment of an active industrial exoskeleton to aid dynamic lifting and lowering manual handling tasks
Open accessAbstract
The aim of this study was to evaluate the effect of an industrial exoskeleton on muscle activity, perceived musculoskeletal effort, measured and perceived contact pressure at the trunk, thighs and shoulders, and subjective usability for simple sagittal plane lifting and lowering conditions. Twelve male participants lifted and lowered a box of 7.5 kg and 15 kg, respectively, from mid-shin height to waist height, five times, both with and without the exoskeleton. The device significantly reduced muscle activity of the Erector Spinae (12%-15%) and Biceps Femoris (5%). Ratings of perceived musculoskeletal effort in the trunk region were significantly less with the device (9.5%-11.4%). The measured contact pressure was highest on the trunk (91.7 kPa-93.8 kPa) and least on shoulders (47.6 kPa-51.7 kPa), whereas pressure was perceived highest on the thighs (35-44% of Max LPP). Six of the users rated the device usability as acceptable. The exoskeleton reduced musculoskeletal loading on the lower back and assisted with hip extensor torque during lifting and lowering. Contact pressures fell below the Pain Pressure Threshold. Perceived pressure was not exceptionally high, but sufficiently high to cause discomfort if used for long durations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Muscle fatigue: what, why and how it influences muscle function
Enoka, R. M., & Duchateau, J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139477 · Cited by 1,672
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Self-citationReview of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Intrinsic risk factors for exercise-related injuries among male and female army trainees
Jones, B. H., Bovee, M. W., Harris, J. M., & Cowan, D. N. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100512 · Cited by 516
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Self-citationDetermining what individual SUS scores mean
(2009) · Journal of Usability Studies archive · doi:10.5555/2835587.2835589 · Cited by 412
Bodyspace: Anthropometry, Ergonomics and the Design of Work, Third Edition
PHEASANT, S. T., & Haslegrave, C. M. (2016) · Medical Entomology and Zoology · Cited by 398
Wearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 394
The Effect of Lumbar Fatigue on the Ability to Sense a Change in Lumbar Position: A Controlled Study
Taimela, S., Kankaanpää, M., & Luoto, S. (1999) · Spine · doi:10.1097/00007632-199907010-00009 · Cited by 310
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Employment and Physical Work Activities as Predictors of Future Low Back Pain
Macfarlane, G. J., Thomas, E., Papageorgiou, A. C., Croft, P. R., Jayson, M. I. V., & Silman, A. J. (1997) · Spine · doi:10.1097/00007632-199705150-00015 · Cited by 253
Wearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
Bodyspace: Anthropometry, Ergonomics And The Design Of Work
(2002) · Routledge eBooks · doi:10.4324/9780203482650 · Cited by 218
Ergonomic contribution of ABLE exoskeleton in automotive industry
Sylla, N., Bonnet, V., Collédani, F., & Fraisse, P. (2014) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.03.008 · Cited by 213
Nilsson, A., Vreede, K., Häglund, V., Kawamoto, H., Sankai, Y., & Borg, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-92 · Cited by 206
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.014 · Cited by 134
Collins, J. D., & O'Sullivan, L. W. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.12.013 · Cited by 126
Self-citationSensitivity of the hand to surface pressure
Fransson‐Hall, C., & Kilbom, Å. (1993) · Applied Ergonomics · doi:10.1016/0003-6870(93)90006-u · Cited by 121
Real-Time Strap Pressure Sensor System for Powered Exoskeletons
Tamez-Duque, J., Cobian-Ugalde, R., Kilicarslan, A., Venkatakrishnan, A., Soto, R., & Contreras-Vidal, J. L. (2015) · Sensors · doi:10.3390/s150204550 · Cited by 83
Masbernat, M. A., Cempini, M., Gómez, C., Cortese, M., Martín, C., Medina-Casanovas, J., Vitiello, N., & Opisso, E. (2015) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2015.1079653 · Cited by 73
Subject-specific, whole-body models of the stooped posture with a personal weight transfer device
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.016 · Cited by 69
Bos, J., Kuijer, P., & Frings‐Dresen, M. H. W. (2002) · Occupational and Environmental Medicine · doi:10.1136/oem.59.12.800 · Cited by 68
Matthew, R. P., Mica, E. J., Meinhold, W., Loeza, J. A., Tomizuka, M., & Bajcsy, R. K. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354133 · Cited by 32
Cited by
Kermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Self-citationEvaluation of a passive exoskeleton for static upper limb activities
Huysamen, K., Bosch, T., de Looze, M., Stadler, K. S., Graf, E., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.009 · Cited by 253
Self-citationOjha, A., Gautam, Y., Jebelli, H., & Akanmu, A. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105742 · Cited by 39
Metadata
- Authors
- Huysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W.
- Venue
- Applied Ergonomics
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 68
- Pages
- 125-131
- ISSN
- 0003-6870 (ISSN-L)
- OpenAlex
- W2771030923
- Cited by
- 313
- References
- 26
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.