CoChat

A Novel Video Game–Based Device for Measuring Stepping Performance and Fall Risk in Older People

Open access
Schoene, Daniel, Lord, Stephen R., Verhoef, Paulien, Smith, Stuart T. · 2011 · Archives of Physical Medicine and Rehabilitation
Cited by 71

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE To determine whether a dance mat test of choice stepping reaction time (CSRT) is reliable and can detect differences in fall risk in older adults. DESIGN Randomized order, crossover comparison. SETTING Balance laboratory, medical research institute, and retirement village. PARTICIPANTS Older (mean age, 78.87±5.90y; range, 65-90y) independent-living people (N=47) able to walk in place without assistance. INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES Reaction (RT), movement, and response times of dance pad--based stepping tests, Physiological Profile Assessment (PPA) score, Digit Symbol Substitution Test (DSST) score, time to complete the Trail Making Test (TMT) A+B, Fall Efficacy Scale International (FES-I) score, Activities-specific Balance Confidence (ABC) Scale score, and Incidental and Planned Exercise Questionnaire (IPEQ) incidental IPEQ activity subscore. RESULTS Test-retest reliability of the dance mat CSRT response time was high (intraclass correlation coefficient model 3,k=.90; 95% confidence interval [CI], .82-.94; P<.001) and correlated highly with the existing laboratory-based measure (r=.86; 95% CI, .75-.92; P<.001). Concurrent validity was shown by significant correlations between response time and measures of fall risk (PPA: r=.42; 95% CI, .15-.63; P<.01; TMT A: r=.61; 95% CI, .39-.77; TMT B: r=.55; 95% CI, .31-.72; DSST: r=-.53; 95% CI, -.71 to -.28; P<.001; FES-I: Spearman ρ=.50; 95% CI, .25-.69; ABC Scale: Spearman ρ=-.58; 95% CI, -.74 to -.35; P<.01). Participants with moderate/high fall-risk scores (PPA score >1) had significantly slower response times than people with low/mild fall-risk scores (PPA score <1) at 1146±182 and 1010±132ms, respectively (P=.005), and multiple fallers and single/nonfallers showed significant differences in RT (883±137 vs 770±100ms; P=.009) and response time (1180±195 vs 1031±145ms; P=0.017). CONCLUSIONS The new dance mat device is a valid and reliable tool for assessing stepping ability and fall risk in older community-dwelling people. Because it is highly portable, it can be used in clinic settings and the homes of older people as both an assessment and training device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apmr.2011.01.012

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 71

Metadata

Authors
Schoene, D., Lord, S. R., Verhoef, P., & Smith, S. T.
Venue
Archives of Physical Medicine and Rehabilitation
Publisher
Elsevier BV
Published
2011-06
Volume
92
Issue
6
Pages
947-953
ISSN
0003-9993 (ISSN-L)
OpenAlex
W2124899116
Cited by
71
References
3
FWCI
15.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.