Cited by 39Adsorption and Cooling SystemsBuilding Energy and Comfort OptimizationHygrothermal properties of building materials

The DOI matches its Crossref record; 9 of the 10 references it cites were found in a registry or an index.

Performance evaluation of indirect evaporative cooling using whole-building hygrothermal simulations

Open access
Steeman, Marijke, Janssens, Arnold, De Paepe, Michel·2009·Applied Thermal Engineering

Overview

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2009.02.004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Low-energy cooling strategies that work well today might not remain effective under long-term climate change, or in extreme events such as a heatwave or a power failure.

    “This is supported by the findings of several studies [11,12,13], which show that the low-energy cooling strategies that work well today might not remain effective under long-term climate change, or in extreme events such as a heatwave or a power failure.”

Citations

Cites

Flagged first, then by citations

1 of the 10 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. ASHRAE, Chapter 51: evaporative cooling applications, in: Fundamentals Handbook: HVAC Applications. American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta, USA, 2003.
  2. H. Hens, Annex 41, Whole Building Heat, Air and Moisture Response (MOIST-ENG). ECBCS News, vol. 38, 2003, pp. 1–3. <www.ecbcs.org/annexes/annex41.htm>.
  3. K. Svennberg, L. Hedegaard, C. Rode, Moisture buffer performance of a fully furnished room, in: Proceedings of Buildings IX Conference, ASHRAE Special Publications, 2004.

Cited by

Sorted by citations

Metadata

Authors
Steeman, M., Janssens, A., & De Paepe, M.
Affiliations
Ghent University (BE)
Corresponding author
Steeman, Marijke
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2009-10
Volume
29
Issue
14-15
Pages
2870-2875
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2043567469
Cited by
38
References
10
Citations by year
2026: 2 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 4 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
9.45
Type
journal article
Language
en
Open access
Locations
  • Applied Thermal Engineering (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
  • Trinity's Access to Research Output (TARA) (Trinity College Dublin) (submittedVersion)
Funders
Vlaamse regering
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Building and Construction › Hygrothermal properties of building materials
Keywords
indirect evaporative cooling, hygrothermal simulation, thermal effectiveness, heat and moisture balance, ventilation rate, moisture buffering capacity, hygroscopic materials, whole building energy simulation, TRNSYS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review