A study on the performance enhancement of heat pump using electric heater under the frosting condition: Heat pump under frosting condition
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
At outdoor temperature 4 °C dry bulb/2 °C wet bulb, proposed heat pump had heating capacity 9.1% higher and average COP 71.1% higher than conventional heat pump, and average power consumption 31.6% lower.
“At an outdoor temperature of 4 ° C (dry bulb)/2 ° C (wet bulb), the heating capacity and the average COP of the proposed model were 9.1% and 71.1% higher than those of a conventional heat pump, respectively (Fig. 6). The average power consumption during operation was 31.6% lower than that of a conventional heat pump.”
At outdoor temperature 2 °C dry bulb/1 °C wet bulb, proposed heat pump with electric heater had heating capacity 38.0% higher and average COP 57.0% higher than conventional heat pump, and average power consumption 11.7% less.
“At an outdoor temperature of 2 ° C (dry bulb)/1 ° C (wet bulb), the heating capacity and average COP of the proposed model were 38.0% and 57.0%, respectively, higher than those of a conventional heat pump. Indeed, the average power consumption during operation was 11.7% less than that of a conventional pump.”
Cites
Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger
Jhee, S., Lee, K.-S., & Kim, W.-S. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(02)00008-7 · Cited by 149 · see citing works
Hot gas defrost model development and validation
Hoffenbecker, N., Klein, S. A., & Reindl, D. T. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.08.016 · Cited by 84 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384 · see citing works
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218 · see citing works
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Song, M., Fan, C., Mao, N., & Xu, Y. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.027 · Cited by 51 · see citing works
A new method of defrosting evaporator coils
Mader, G., & Thybo, C. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.01.033 · Cited by 37 · see citing works
Experimental investigation on an air source heat pump system with a novel anti-frosting evaporator
Yu, S., Su, Y., Cai, W., & Qiu, G. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119910 · Cited by 29 · see citing works
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29 · see citing works
Experimental study of solution defrosting characteristics of air source heat pump
Jiang, P., Zhang, Y., Fan, H., Jin, Q., & Yu, Y. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121575 · Cited by 7 · see citing works
- Authors
- Kwak, K., & Bai, C.
- Affiliations
- Yeungnam University (KR)
- Corresponding author
- Bai, Cheolho
- ORCID
- Bai, Cheolho
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 30
- Issue
- 6-7
- Pages
- 539-543
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W1978779117
- Cited by
- 101
- References
- 2
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 13 · 2023: 7 · 2022: 8 · 2021: 6 · 2020: 9 · 2019: 7 · 2018: 7 · 2017: 12 · 2016: 4 · 2015: 3 · 2014: 5 · 2013: 1 · 2012: 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- Yeungnam University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- air-to-air heat pump, frost formation, electric heater, heating capacity, coefficient of performance, outdoor unit, evaporator temperature control, on-off operation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review