Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The louver-fin, wavy-fin, strip-fin, plain fins and pins are augmented heat transfer surfaces used on the air-side of both microchannels and compact heat exchangers.
“the louver-fin, wavyfin, strip-fin, plain fins and pins are augmented heat transfer surface used on the air-side of both microchannels and compact heat exchangers [23-34].”
From Compact and microchannel heat exchangers: A comprehensive review of air-side friction factor and heat transfer correlations (2018) · cites this paper as [31]
The indexed passage labeled Applied Thermal Engineering 31(5), pp. 742–749, describes louvered fins on microchannel coils and a wavy-plate-fin heat exchanger. It does not support the inclusion of strip fins, plain fins, or pins, or establish that all five surfaces are used on the air side of both heat-exchanger types. (LLM, conf=0.85)
Experimental — accuracy not yet measuredFor a gas-to-liquid microchannel heat exchanger, the air-side can be constructed between the microchannel slabs, similar to the air-side of compact heat exchangers.
“For a gas-to-liquid microchannel heat exchangers, the air-side can be constructed between the microchannel slabs, similar to the air-side of compact heat exchangers”
From Compact and microchannel heat exchangers: A comprehensive review of air-side friction factor and heat transfer correlations (2018) · cites this paper as [31]
The available indexed passage (ORBi record, abstract for Applied Thermal Engineering 31, pp. 742–749) discusses the air-side performance of microchannel coils and their louvered fins, but does not describe where the air-side is constructed. Searches for air passages between microchannel slabs and for the coil geometry returned no passage addressing that construction or its similarity to compact heat exchangers. (LLM, conf=0.73)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Common Faults and Their Impacts for Rooftop Air Conditioners
Breuker, M. S., & Braun, J. E. (1998) · Science and Technology for the Built Environment · doi:10.1080/10789669.1998.10391406 · Cited by 195 · see citing works
Predicting particle deposition on HVAC heat exchangers
Siegel, J. A., & Nazaroff, W. W. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.033 · Cited by 91 · see citing works
The impact of fouling on the performance of filter–evaporator combinations
Yang, L., Braun, J. E., & Groll, E. A. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.08.006 · Cited by 64 · see citing works
Self-citationThe impact of evaporator fouling and filtration on the performance of packaged air conditioners
Yang, L., Braun, J. E., & Groll, E. A. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.08.010 · Cited by 47 · see citing works
Self-citationBell, I. H., Groll, E. A., & König, H. (2010) · Heat Transfer Engineering · doi:10.1080/01457632.2010.495618 · Cited by 46 · see citing works
Self-citationAhn, Y.-C., Cho, J.-M., Shin, H., Hwang, Y., Lee, C.-G., Lee, J.-K., Lee, H. U., & Kang, T.-W. (2003) · Korean Journal of Chemical Engineering · doi:10.1007/bf02697291 · Cited by 45 · see citing works
Impact of fouling and cleaning on plate fin and spine fin heat exchanger performance.
Pak, B. C., Groll, E. A., & Braun, J. (2005) · Cited by 33 · see citing works
Self-citationKaiser, S., Antonijević, D. L., & Tsotsas, E. (2002) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(02)00139-5 · Cited by 33 · see citing works
The effect of air side fouling on thermal-hydraulic characteristics of a compact heat exchanger
Lankinen, R., Suihkonen, J., & Sarkomaa, P. (2003) · International Journal of Energy Research · doi:10.1002/er.880 · Cited by 27 · see citing works
Air-Side Fouling of Compact Heat Exchangers for Discrete Particle Size Ranges
Khoshkhoo, R. H., & McCluskey, F. M. J. (2006) · Heat Transfer Engineering · doi:10.1080/01457630600985675 · Cited by 24 · see citing works
Energy use implications of methods to maintain heat exchanger coil cleanliness
Krafthefer, B. C., & Bonné, U. (1986) · ASHRAE winter conference papers · Cited by 18 · see citing works
Air side fouling of compact heat exchangers
Mason, D. K., Heikal, M., & Douch, N. (2006) · University of Brighton Repository (University of Brighton) · Cited by 11 · see citing works
Reducing Particle Deposition in Air-Cooled Heat Exchangers
Zhang, G., Bott, T. R., & Bemrose, C. R. (1992) · Heat Transfer Engineering · doi:10.1080/01457639208939776 · Cited by 10 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Middis, J., Particulate fouling in heat exchangers with enhanced surfaces (1990) CHEMECA '90, Australasian Chemical Engineering Conference, pp. 1053-1060. , Auckland, NZ
Cited by
Sorted by citations
Fouling in microstructured devices: a review
Schoenitz, M., Grundemann, L., Augustin, W., & Scholl, S. (2015) · Chemical Communications · doi:10.1039/c4cc07849g · Cited by 190 · see citing works
Qasem, N. A. A., & Zubair, S. M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.06.104 · Cited by 135 · see citing works
Kuruneru, S. T. W., Kambiz Vafai, B., Sauret, E., & Gu, Y. (2020) · Chemical Engineering Science · doi:10.1016/j.ces.2020.115968 · Cited by 98 · see citing works
Parameter study on the fouling characteristics of the H-type finned tube heat exchangers
Wang, F., He, Y., Tang, S., & Tong, Z.-X. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.04.107 · Cited by 92 · see citing works
Numerical model of particle deposition on fin surface of heat exchanger
Zhan, F., Zhuang, D., Ding, G., & Tang, J. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.07.015 · Cited by 71 · see citing works
Wang, F.-L., Tang, S., He, Y.-L., Kulacki, F. A., & Yu, Y. (2018) · Fuel · doi:10.1016/j.fuel.2018.09.081 · Cited by 66 · see citing works
Design of surfaces for controlling hard and soft fouling
Halvey, A. K., Macdonald, B., Dhyani, A., & Tuteja, A. (2018) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2018.0266 · Cited by 61 · see citing works
Qureshi, B. A., & Zubair, S. M. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.08.012 · Cited by 58 · see citing works
Zhan, F., Tang, J., Ding, G., & Zhuang, D. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.01.136 · Cited by 59 · see citing works
Li, X., Wang, S. Q., Yang, D. L., Tang, G. H., & Wang, Y. C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.116724 · Cited by 53 · see citing works
Mechanical sub-cooling vapor compression systems: Current status and future directions
Qureshi, B. A., & Zubair, S. M. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.07.026 · Cited by 49 · see citing works
Qureshi, B. A., & Zubair, S. M. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.08.021 · Cited by 48 · see citing works
Thermo-economic optimisation of industrial milk spray dryer exhaust to inlet air heat recovery
Walmsley, T. G., Walmsley, M. R. W., Atkins, M. J., Neale, J. R., & Tarighaleslami, A. H. (2015) · Energy · doi:10.1016/j.energy.2015.03.102 · Cited by 47 · see citing works
Thermal-flow characteristics of the new wave-finned flat tube bundles in air-cooled condensers
Yang, L., Tan, H., Du, X., & Yang, Y. (2011) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2011.11.002 · Cited by 47 · see citing works
Li, G., Hu, Y., Chen, H., Wang, J., Guo, Y., Liu, J., & Li, J. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.04.041 · Cited by 45 · see citing works
Chang, S.-H., Jang, H., Jeon, J., Lee, K.-S., & Kim, D. R. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110139 · Cited by 43 · see citing works
Zhan, F., Zhuang, D., Ding, G., Ju, P., & Tang, J. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.04.049 · Cited by 43 · see citing works
A Review on Applications of Superhydrophobic Materials in Civil Engineering
Wang, N., Wang, Q., & Xu, S. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202101238 · Cited by 40 · see citing works
Hu, Y., Yuill, D. P., & Ebrahimifakhar, A. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.119423 · Cited by 39 · see citing works
A semi-experimental method for evaluating frosting performance of air source heat pumps
Pu, J., Shen, C., Zhang, C., & Liu, X.-J. (2021) · Renewable Energy · doi:10.1016/j.renene.2021.04.029 · Cited by 38 · see citing works
Performance degradation of a vapor compression refrigeration system under fouled conditions
Qureshi, B. A., & Zubair, S. M. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.02.012 · Cited by 36 · see citing works
Impact of airside fouling on microchannel heat exchangers
Zhang, C., Tang, Z., Zhang, Z., Shi, J., Chen, J., & Zhang, M. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.08.163 · Cited by 31 · see citing works
Prediction of air-side particulate fouling of HVAC&R heat exchangers
Inamdar, H. V., Groll, E. A., Weibel, J. A., & Garimella, S. V. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.05.082 · Cited by 29 · see citing works
Self-citationKroulíková, T., Kůdelová, T., Bartuli, E., Vančura, J., & Astrouski, I. (2021) · Polymers · doi:10.3390/polym13071175 · Cited by 29 · see citing works
Dezan, D. J., Salviano, L., & Yanagihara, J. I. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.08.072 · Cited by 28 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
Ultraviolet germicidal coil cleaning: Impact on heat transfer effectiveness and static pressure drop
Luongo, J. C., Brownstein, J., & Miller, S. L. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.11.022 · Cited by 25 · see citing works
Catrini, P., Villetta, M. L., Kumar, D. M., Morale, M., & Piacentino, A. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123393 · Cited by 24 · see citing works
Cao, Q., Xu, Q., Liu, W., Lin, C., Wei, D., Baughcum, S. L., Norris, S., & Chen, Q. (2017) · Atmospheric Environment · doi:10.1016/j.atmosenv.2017.01.044 · Cited by 24 · see citing works
Lin, Y., Wang, W., Sun, Y., Liu, J., & Deng, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.031 · Cited by 23 · see citing works
Micro/Nanoscale surface modifications to combat heat exchanger fouling
Goswami, A., Pillai, S. C., & McGranaghan, G. J. (2023) · Chemical Engineering Journal Advances · doi:10.1016/j.ceja.2023.100519 · Cited by 23 · see citing works
Deposition of dry particles on a fin-and-tube heat exchanger by a coupled soft-sphere DEM and CFD
Välikangas, T., Hærvig, J., Kuuluvainen, H., Maso, M. D., Peltonen, P., & Vuorinen, V. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.119046 · Cited by 23 · see citing works
Cao, L., Liu, J., Li, R., Huang, S., Zhang, F., & Xu, X. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.10.026 · Cited by 21 · see citing works
Wang, Y., Sekhar, C., Bahnfleth, W. P., Cheong, D. K. W., & Firrantello, J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.063 · Cited by 21 · see citing works
Walmsley, T. G., Walmsley, M. R. W., Atkins, M. J., Hoffmann-Vocke, J., & Neale, J. R. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.527 · Cited by 20 · see citing works
Effect of surface wettability of fins on dust removal by condensate water
Yang, Y., Zhuang, D., & Ding, G. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.11.043 · Cited by 20 · see citing works
Fouling and Its Effects on Air-cooled Condensers in Split System Air Conditioners (RP-1705)
Mehrabi, M., & Yuill, D. P. (2019) · Science and Technology for the Built Environment · doi:10.1080/23744731.2019.1605197 · Cited by 20 · see citing works
Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation
Kim, J.-H., Frank, S., Im, P., Braun, J. E., Goldwasser, D., & Leach, M. (2019) · Buildings · doi:10.3390/buildings9120239 · Cited by 19 · see citing works
Jafarinejad, T., Shafii, M. B., & Roshandel, R. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100744 · Cited by 18 · see citing works
Air-side fouling of finned heat exchangers: Part 1, review and proposed test protocol
Inamdar, H. V., Groll, E. A., Weibel, J. A., & Garimella, S. V. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.02.017 · Cited by 18 · see citing works
Self-citationKumar, D. M., Catrini, P., Piacentino, A., & Cirrincione, M. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.117258 · Cited by 17 · see citing works
Kuruneru, S. T. W., Saha, S. C., Sauret, E., & Gu, Y. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.01.041 · Cited by 17 · see citing works
Miao, L., Wang, Y., Кавтарадзе, Р. З., Guo, F., & Li, Y. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120879 · Cited by 15 · see citing works
Fouling of Polymeric Hollow Fiber Heat Exchangers by Air Dust
Astrouski, I., Raudenský, M., Kůdelová, T., & Kroulíková, T. (2020) · Materials · doi:10.3390/ma13214931 · Cited by 15 · see citing works
Effect of surface wettability on dust removal characteristics during frosting cleaning process
Li, Y., Li, M., & Dang, C. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120592 · Cited by 14 · see citing works
Assessment of Heat Exchanger Degradation in a Boeing 737-800 Environmental Control System
Jennions, I. K., & Ali, F. (2021) · Journal of Thermal Science and Engineering Applications · doi:10.1115/1.4050324 · Cited by 14 · see citing works
Inamdar, H. V., Groll, E. A., Weibel, J. A., & Garimella, S. V. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.03.016 · Cited by 13 · see citing works
Self-citationA numerical analysis of ash fouling characteristics in elliptical tube bundles
Cui, J., Li, M., Xu, W., Lin, Z., Zhu, L., & Jin, Y. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121436 · Cited by 13 · see citing works
Fouling and pressure drop analysis of milk powder deposition on the front of parallel fins
Walmsley, T. G., Walmsley, M. R. W., Atkins, M. J., & Neale, J. R. (2013) · Advanced Powder Technology · doi:10.1016/j.apt.2013.04.004 · Cited by 13 · see citing works
Wang, K., Li, N., Peng, J., Wang, X., Wang, C., & Wang, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.12.023 · Cited by 13 · see citing works
Guan, Q., Li, H., Goharzadeh, A., Islam, M., Wei, K. C., & Fatt, Y. Y. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121570 · Cited by 12 · see citing works
Experimental investigation of the air side fouling of finned tube heat exchangers
Edelin, D., Bariteau, N., Etourneau, Y., Traonvouez, L., & Soto, J. (2019) · Heat and Mass Transfer · doi:10.1007/s00231-019-02612-2 · Cited by 12 · see citing works
Jain, V., Sachdeva, G., & Kachhwaha, S. S. (2014) · Journal of Energy in Southern Africa · doi:10.17159/2413-3051/2014/v25i4a2234 · Cited by 12 · see citing works
A novel ‘‘partial bypass” concept to augment the performance of air-cooled heat exchangers
Wang, C., Chen, K., Liaw, J.-S., & Tseng, C.-Y. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.05.031 · Cited by 12 · see citing works
Li, Z., Wang, W., Sun, Y., Liu, J., Deng, S., & Liang, S. (2019) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2019.03.039 · Cited by 11 · see citing works
Greiciunas, E., Borman, D. J., Summers, J. L., & Smith, S. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116501 · Cited by 11 · see citing works
Tonkovich, A. L., & Daymo, E. (2018) · Springer eBooks · doi:10.1007/978-3-319-26695-4_34 · Cited by 13 · see citing works
Reduction of dust deposition in air-cooled condensers in thermal power plants by Ni–P-based coatings
Zhao, B., Wang, X., Xu, Y., Liu, B., Cao, S., & Zhao, Q. (2021) · Clean Technologies and Environmental Policy · doi:10.1007/s10098-021-02055-6 · Cited by 10 · see citing works
Ryu, M., Choi, H., Yoon, J., Choi, Y., Lee, S., Kim, H., Chae, M., Lee, J. W., Kang, J., & Lee, H. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.138657 · Cited by 10 · see citing works
Predicting the impact of heat exchanger fouling in refrigeration systems
Qureshi, B. A., & Zubair, S. M. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.05.002 · Cited by 10 · see citing works
Pu, J., Shen, C., Yang, H.-T., & Wen, M. (2021) · Energy for Sustainable Development · doi:10.1016/j.esd.2021.10.007 · Cited by 8 · see citing works
Cui, Z., Jing, H., Wang, D., Wang, B., & Chen, W. (2025) · Energy · doi:10.1016/j.energy.2025.135419 · Cited by 7 · see citing works
Catrini, P., & Piacentino, A. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121159 · Cited by 7 · see citing works
Romanowicz, T., Taler, J., Jaremkiewicz, M., & Sobota, T. (2023) · Energies · doi:10.3390/en16176264 · Cited by 7 · see citing works
Liu, J., Wei, X., Zhou, Z.-Y., & Wei, Z.-W. (2018) · Heat and Mass Transfer · doi:10.1007/s00231-018-2285-7 · Cited by 6 · see citing works
Wang, Y., Sekhar, C., Bahnfleth, W. P., Cheong, D. K. W., & Firrantello, J. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1232115 · Cited by 6 · see citing works
Catrini, P., & Piacentino, A. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.127578 · Cited by 5 · see citing works
A laboratory test method to realistically simulate air side fouling of condensers (RP-1705)
Mehrabi, M., & Yuill, D. P. (2020) · Science and Technology for the Built Environment · doi:10.1080/23744731.2020.1737489 · Cited by 5 · see citing works
Carrasco, F. J. C., Guillamón, M. P., & Vicente, F. S. (2021) · Applied Sciences · doi:10.3390/app11052019 · Cited by 5 · see citing works
Tonkovich, A. L., & Daymo, E. (2017) · Springer eBooks · doi:10.1007/978-3-319-32003-8_34-1 · Cited by 5 · see citing works
Enhanced Heat Transfer Performance of Air-Cooled Heat Exchangers Using “Partial Bypass” Concept
Wang, C. (2012) · Heat Transfer Engineering · doi:10.1080/01457632.2012.692293 · Cited by 5 · see citing works
Effect of partial bypass on the heat transfer performance of dehumidifying coils
Wang, C., Cheng, Y. C., Liaw, J.-S., & Tseng, C.-Y. (2014) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2014.08.029 · Cited by 5 · see citing works
Yao, L. Z., Liu, R.-T., Su, D., Wang, S.-M., Wang, L., Zhang, H.-N., Li, X.-B., & Li, F. (2025) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2025.113917 · Cited by 4 · see citing works
Yang, C., Hou, Z., Liao, H., Gao, Y., Hao, R., & Wang, H. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.130749 · Cited by 4 · see citing works
Fluid Flow and Heat Transfer of a Gas Stream Containing Dust Particles in a Parallel-Plates Duct
Pan, A., Cai, R.-R., Dong, C., & Zhang, L. (2022) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.4055433 · Cited by 4 · see citing works
Niknami, M., Maniee, S., rad, A. A. F., Mansoori, S., & Yahaghi, M. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114671 · Cited by 3 · see citing works
Dmitriev, A. V., Дмитриевич, Я. Н., Харьков, В. В., & Бадретдинова, Г. Р. (2023) · Journal of Engineering Physics and Thermophysics · doi:10.1007/s10891-023-02812-y · Cited by 3 · see citing works
Techno-Economic Assessment of Heat Recovery in Series Condensers Arrangement: Hot and Humid Regions
Jafarinejad, T., Yousefi, H., & Choubinehb, K. (2018) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.22097/eeer.2019.163929.1063 · Cited by 2 · see citing works
Determination of the Fouling Degree of the Heat Substation Based on Tests of Plate Heat Exchangers
Romanowicz, T., Jaremkiewicz, M., Kania, A., & Pietruszka, M. (2022) · Heat Transfer Engineering · doi:10.1080/01457632.2022.2113458 · Cited by 2 · see citing works
Deposition Distribution and Thermal Resistance Analysis of Fins in Heat Exchangers
Xu, W., Zhang, S., Yang, Q. Z., Zhang, L., Ge, C., Wang, A., Bu, S., Lv, W., & Zhang, L. (2024) · Energies · doi:10.3390/en17163952 · Cited by 2 · see citing works
Qu, H., Wang, L., Zhang, X. L., Zhang, X., & Huang, S. (2024) · Journal of Chemical & Engineering Data · doi:10.1021/acs.jced.4c00309 · Cited by 2 · see citing works
Yang, H.-T., Pu, J., Yan, X., & Shen, C. (2025) · The Physics of Fluids · doi:10.1063/5.0258908 · Cited by 3 · see citing works
An investigation of milk powder deposition on parallel fins
Walmsley, T. G., Walmsley, M. R. W., Atkins, M., & Neale (2012) · Research Commons (University of Waikato) · Cited by 2 · see citing works
Aircraft heat exchanger fouling detection based on valve control command
Shang, L., & Liu, G. (2011) · Proceedings of the Institution of Mechanical Engineers Part G Journal of Aerospace Engineering · doi:10.1177/0954410011416058 · Cited by 2 · see citing works
Design of a psychrometric coil testing facility for commercial size heat exchanger coils
Kincheloe, M. C., Franke, J. P., Bach, C. K., & Bradshaw, C. R. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.10.027 · Cited by 2 · see citing works
Checketts, G. T. (2014) · doi:10.12794/metadc700005 · Cited by 2 · see citing works
POLYMERIC HOLLOW FIBERS SERVING AS A CROSS-FLOWHEAT EXCHANGER IN LIQUID-TO-GAS APPLICATIONS
Hvožďa, J., Bartuli, E., & Raudenský, M. (2023) · Proceeding of Second Thermal and Fluids Engineering Conference · doi:10.1615/tfec2023.hex.045915 · Cited by 1 · see citing works
Experimental study on spray-induced fouling on the outer surface of heat exchangers
Liu, L., Liu, H., Li, Y., Sun, R., & Liu, X. (2026) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2026.108733 · Cited by 1 · see citing works
Enhancing air conditioner efficiency: comparative study of microchannel and Finned-Tube condensers
Abhijith, K. R., & Sadhikh, M. (2025) · Heat and Mass Transfer · doi:10.1007/s00231-025-03586-0 · Cited by 1 · see citing works
Dudarev, V. V., Filatаu, S. O., & Karlovich, T. B. (2017) · ENERGETIKA Proceedings of CIS higher education institutions and power engineering associations · doi:10.21122/1029-7448-2017-60-3-237-255 · Cited by 1 · see citing works
Mehrabi, M., & Yuill, D. P. (2018) · Lincoln (University of Nebraska)
Kuruneru, S. T. W. (2019) · Queensland University of Technology · doi:10.5204/thesis.eprints.125485
Experimental Study on Influencing Factors of Dust Deposition on Mine Air Cooler Fins
Kong, L., Miao, D., Guo, Z., Jiang, J., & Cheng, Y. (2020) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/571/1/012047
Han, Q., Liu, X. X., Zhang, Y., & Lin, D. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/861/5/052066
Dmitriev, A. V., Бадретдинова, Г. Р., Borisova, S. D., & Николаев, А. Н. (2022) · Power engineering research equipment technology · doi:10.30724/1998-9903-2022-24-1-176-185
Kumar, D. M., Peter, N., Catrini, P., Fagiolini, A., Piacentino, A., & Cirrincione, M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6154930
Esquivel-Puentes, H. A., & Groll, E. A. (2026) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2026.106904
Self-citationCatrini, P., & Piacentino, A. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.132028
Huang, M., Jin, H., Yang, K., Li, C., Xu, A., & Chen, S. (2026) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2026.129686
FLOW NON-UNIFORMITY AND HEAT TRANSFER IN ANNULAR PLATE-FIN RADIATOR
Liu, Z., Li, H., Zhou, Y., Jiang, H., Shi, L., Zhang, Y., & Wang, J. (2014) · UpSpace Institutional Repository (University of Pretoria)
- Authors
- Bell, I. H., & Groll, E. A.
- Affiliations
- Purdue University West Lafayette (US)
- Corresponding author
- Bell, Ian H.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 31
- Issue
- 5
- Pages
- 742-749
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W1968572185
- Cited by
- 100
- References
- 13
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 4 · 2023: 11 · 2022: 5 · 2021: 11 · 2020: 7 · 2019: 8 · 2018: 10 · 2017: 6 · 2016: 7 · 2015: 4 · 2014: 5 · 2013: 3 · 2012: 4
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- green
- orbi.uliege.be
- Licence
- Locations
- Applied Thermal Engineering (publishedVersion)
- Purdue e-Pubs (Purdue University System) (submittedVersion)
- ORBi (University of Liège) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Ocean Engineering › Particle Dynamics in Fluid Flows
- Keywords
- particulate fouling, microchannel heat exchangers, plate-fin heat exchanger, air-side pressure drop, heat transfer performance, dust deposition, louvered fins, fin spacing, fouling resistance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review