The DOI matches its Crossref record.
Dynamic coupled thermal-and-electrical modelling of sheet-and-tube hybrid photovoltaic/thermal (PVT) collectors
Open accessAbstract
In this paper we present a dynamic model of a hybrid photovoltaic/thermal (PVT) collector with a sheet-and-tube thermal absorber. The model is used in order to evaluate the annual generation of electrical energy along with the provision of domestic hot-water (DHW) from the thermal energy output, by using real climate-data at high temporal resolution. The model considers the effect of a non-uniform temperature distribution on the surface of the solar cell on its electrical power output. An unsteady 3-dimensional numerical model is developed to estimate the performance of such a collector. The model allows key design parameters of the PVT collector to vary so that the influence of each parameter on the system performance can be studied at steady state and at varying operating and atmospheric conditions. A key parameter considered in this paper is the number of glass covers used in the PVT collector. The results show that while the thermal efficiency increases with the additional glazing, the electrical efficiency deteriorates due to the higher temperature of the fluid and increased optical losses, as expected. This paper also shows that the use of a dynamic model and of real climate-data at high resolution is of fundamental importance when evaluating the yearly performance of the system. The results of the dynamic simulation with 1-min input data show that the thermal output of the system is highly dependent on the choice of the control parameters (pump operation, differential thermostat controller, choice of flow rate etc.) in response to the varying weather conditions. The effect of the control parameters on the system's annual performance can be captured and understood only if a dynamic modelling approach is used. The paper also discusses the use of solar cells with modified optical properties (specifically, reduced absorptivity/emissivity) in the infrared spectrum, which would reduce the thermal losses of the PVT collector at the cost of only a small loss in electrical output when the selective coating is applied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of solar hybrid photovoltaic-thermal (PV-T) collectors and systems
Herrando, M., Wang, K., Huang, G., Otanicar, T., Mousa, O. B., Agathokleous, R. A., Ding, Y., Kalogirou, S., Ekins-Daukes, N., Taylor, R. A., et al. (2023) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2023.101072 · Cited by 321
Self-citationDynamic Modeling and Experimental Validation of the Photovoltaic/Thermal System
Sredenšek, K., Simonič, E., Deželak, K., Bizjak, M., Lukač, N., & Seme, S. (2025) · Applied Sciences · doi:10.3390/app151910505 · Cited by 4
Metadata
- Authors
- Guarracino, I., Mellor, A., Ekins-Daukes, N. J., & Markides, C. N.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 101
- Pages
- 778-795
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2288755564
- Cited by
- 248
- References
- 0
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic coupled thermal-and-electrical modelling of sheet-and-tube hybrid photovoltaic/thermal (PVT) collectors. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2016.02.056
- The paper
- Guarracino, I., Mellor, A., Ekins-Daukes, N. J., & Markides, C. N. (2016). Dynamic coupled thermal-and-electrical modelling of sheet-and-tube hybrid photovoltaic/thermal (PVT) collectors. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2016.02.056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.