Effect of hydraulic diameter and aspect ratio on single phase flow and heat transfer in a rectangular microchannel
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The effect of aspect ratio and hydraulic diameter on single phase flow and heat transfer in a single microchannel was investigated numerically and the results are presented in this paper. Previously, many studies in literature investigating the effect of geometrical parameters reached contradictory conclusions leaving some phenomena unexplained. Additionally, most researchers studied the effect of channel geometry by varying the channel height for a constant channel width or varying the width for a constant height. This means that the hydraulic diameter and aspect ratio vary simultaneously, which makes it difficult to identify the relative importance of the aspect ratio and the hydraulic diameter. In the present study, the effect of hydraulic diameter was studied by varying the channel width and depth while keeping the aspect ratio constant. The range of hydraulic diameters was 0.1–1 mm and the aspect ratio was fixed at 1. In the second set of simulations, the aspect ratio ranged from 0.39 to 10 while the hydraulic diameter was kept constant at 0.56 mm. The simulations were performed using the CFD software package ANSYS Fluent 14.5. The geometry investigated in this study includes symmetrical cylindrical inlet and outlet plenums and a microchannel. The fluid entered and left the channel vertically from the top in a direction normal to the channel axis. The dimensions of the inlet/outlet plenums (diameter and height measured from the channel bottom surface) were kept constant while the width and depth of the channel were varied. The simulations were conducted for a range of Reynolds numbers (Re = 100–2000) and water was used as the working fluid. A three dimensional thin wall model was used to avoid conjugate heat transfer effects. A constant heat-flux boundary condition was applied at the bottom and vertical side walls of the channel, while the upper wall was considered adiabatic. The friction factor was found to decrease slightly with aspect ratio up to AR ≈ 2 after which it increased with increasing aspect ratio. The results demonstrated that the slope of the velocity profile at the channel wall changes significantly with aspect ratio for AR > 2. The effect of the aspect ratio and hydraulic diameter on the dimensionless hydrodynamic entry length is not significant. Also, the aspect ratio does not affect the heat transfer coefficient while the dimensionless Nusselt number increases with increasing hydraulic diameter. The friction factor was found to increase with increasing hydraulic diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Cryogenic Heat Transfer · doi:10.1201/b15230-9 · Cited by 3,534
Laminar Flow Forced Convection in Ducts
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-06152-x · Cited by 2,837
(2007) · doi:10.1002/9780470172605 · Cited by 2,813
Qu, W., & Mudawar, I. (2002) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(01)00337-4 · Cited by 1,033
Investigation of heat transfer in rectangular microchannels
Lee, P.-S., Garimella, S. V., & Liu, D. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.11.019 · Cited by 829
Thermally developing flow and heat transfer in rectangular microchannels of different aspect ratios
Lee, P.-S., & Garimella, S. V. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.02.011 · Cited by 455
Three-dimensional conjugate heat transfer in the microchannel heat sink for electronic packaging
Fedorov, A. G., & Viskanta, R. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00151-9 · Cited by 446
Characterization of frictional pressure drop for liquid flows through microchannels
Judy, J., Maynes, D., & Webb, B. W. (2002) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00076-5 · Cited by 427
Gunnasegaran, P., Mohammed, H. A., Shuaib, N. H., & Saidur, R. (2010) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2010.06.014 · Cited by 387
FRICTIONAL FLOW CHARACTERISTICS OF WATER FLOWING THROUGH RECTANGULAR MICROCHANNELS
Peng, X. F., Peterson, G. P., & Wang, B. X. (1994) · Experimental Heat Transfer · doi:10.1080/08916159408946484 · Cited by 381
Cited by
Latest Advancements in Heat Transfer Enhancement in the Micro-channel Heat Sinks: A Review
Ramesh, K. N., Sharma, T. K., & Rao, G. A. P. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-020-09495-1 · Cited by 202
The role of microchannel geometry selection on heat transfer enhancement in heat sinks: A review
Dash, B., Nanda, J., & Rout, S. K. (2022) · Heat Transfer · doi:10.1002/htj.22357 · Cited by 41
“Sahar et al.(4) have clearly examined the effect of hydraulic diameter changing values along with aspect ratio.”
Background
Metadata
- Authors
- Sahar, A. M., Wissink, J., Mahmoud, M. M., Karayiannis, T. G., & Ashrul Ishak, M. S.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 115
- Pages
- 793-814
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2571139366
- Cited by
- 172
- References
- 20
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of hydraulic diameter and aspect ratio on single phase flow and heat transfer in a rectangular microchannel. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2017.01.018
- The paper
- Sahar, A. M., Wissink, J., Mahmoud, M. M., Karayiannis, T. G., & Ashrul Ishak, M. S. (2017). Effect of hydraulic diameter and aspect ratio on single phase flow and heat transfer in a rectangular microchannel. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2017.01.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.