Abstract
Industrial waste heat is examined in EU countries, focusing on the amount that can be recovered and exploited, referred to as technical potential of waste heat. An alternative methodology is proposed here, which is based on waste heat fractions derived from a detailed study of the UK industry from the period 2000–2003. These fractions express the part of heat consumption that is wasted and is possible to be recovered. The waste heat fractions have been calculated in this work for each main industrial sector and temperature level. The methodology initially includes the adjustment of waste heat fractions from each industrial sector from the UK industry to the conditions of the different EU countries in the period 2000–2003, in order to account for the different levels of energy efficiency. The second step is to adjust the fractions for the year 2015, using data about the evolution of energy intensity values from 2000 to 2003 to 2015 for each country and sector, resulting to a new set of fractions per country, temperature level and sector. This methodology has enabled the authors to study in detail the waste heat potential per sector and temperature level, using the most recent data. The main outcome is the estimation of waste heat potential for each main industrial sector in the EU, broken down to the amount of waste heat for each temperature range. A similar analysis is conducted for each EU country as well, in order to identify the magnitude of heat recovery opportunities that could exist for every industrial sector at country level. The main result of this analysis is the estimation of the total waste heat potential in EU, which is about 300 TWh/year, with one third corresponding to temperature level below 200 °C, which is often referred to as low-temperature waste heat, another 25% in the range 200–500 °C and the rest above 500 °C (mostly in the range 500–1000 °C). The findings of the current study can be used for assessing the potential of any relevant heat recovery applications, such as heat upgrade and re-use or heat-to-power conversion technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brückner, S., Liu, S., Miró, L., Radspieler, M., Cabeza, L. F., & Lävemann, E. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.01.147 · Cited by 597
Mapping and discussing Industrial Waste Heat (IWH) potentials for different countries
Miró, L., Brückner, S., & Cabeza, L. F. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.06.035 · Cited by 206
Quantification of the European industrial heat demand by branch and temperature level
Naegler, T., Simon, S., Klein, M., & Gils, H. C. (2015) · International Journal of Energy Research · doi:10.1002/er.3436 · Cited by 166
Brueckner, S., Miró, L., Cabeza, L. F., Pehnt, M., & Laevemann, E. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.04.078 · Cited by 163
Feasibility Study for Recovering Waste Heat in the Steelmaking Industry Using a Chemical Recuperator
Maruoka, N., Mizuochi, T., Purwanto, H., & Akiyama, T. (2004) · ISIJ International · doi:10.2355/isijinternational.44.257 · Cited by 162
Heat recovery opportunities in UK industry
Hammond, G. P., & Norman, J. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.11.008 · Cited by 143
Spatial modelling of industrial heat loads and recovery potentials in the UK
McKenna, R., & Norman, J. (2010) · Energy Policy · doi:10.1016/j.enpol.2010.05.042 · Cited by 142
Cited by
A review of thermal energy storage technologies for seasonal loops
Mahon, H., O'Connor, D., Friedrich, D., & Hughes, B. (2022) · Energy · doi:10.1016/j.energy.2021.122207 · Cited by 344
To decarbonize industry, we must decarbonize heat
Thiel, G. P., & Stark, A. K. (2021) · Joule · doi:10.1016/j.joule.2020.12.007 · Cited by 339
Potential Use of Industrial Biomass Waste as a Sustainable Energy Source in the Future
Kalak, T. (2023) · Energies · doi:10.3390/en16041783 · Cited by 272
Young, J., McQueen, N., Charalambous, C., Foteinis, S., Hawrot, O., Ojeda, M., Pilorgé, H., Andresen, J., Psarras, P., Renforth, P., et al. (2023) · One Earth · doi:10.1016/j.oneear.2023.06.004 · Cited by 239
Orts Mercadillo, V., Chan, K. C., Caironi, M., Athanassiou, A., Kinloch, I. A., Bissett, M., & Cataldi, P. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204772 · Cited by 187
Metadata
- Authors
- Papapetrou, M., Kosmadakis, G., Cipollina, A., La Commare, U., & Micale, G.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 138
- Pages
- 207-216
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2796524268
- Cited by
- 495
- References
- 7
- FWCI
- 9.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.