Numerical comparison between single PCM and multi-stage PCM based high temperature thermal energy storage for CSP tower plants
The DOI matches its Crossref record.
Abstract
This paper is aimed at analyzing the behavior of a packed bed latent heat thermal energy storage system in concentrating solar power (CSP). One way of improving the performance of a latent thermal energy storage system is by implementing the multiple phase change materials (PCMs) design. The behavior of a packed bed latent heat thermal energy storage system at different cases is numerically analyzed. The molten salt is considered for the heat transfer fluid (HTF) with phase change material (PCM) capsules as the filler. In this design, spherical capsules filled with PCMs of different thermo-physical properties are used. The capsules are packed in the bed at different sections based on the PCM melting temperature. The model developed using the Concentric-Dispersion (C-D) equations. The governing equations are solved in MATLAB, and the results obtained are validated against experimental data from the literature. The performance of the systems is calculated. The results show that the three-stage PCMs system with different melting point exhibited the highest energy and exergy efficiency during a charging discharging cycle. Moreover, results show that the three-stage PCMs unit can improve the heat transfer rate greatly and shorten the heat storage time effectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent developments in phase change materials for energy storage applications: A review
Nazir, H., Batool, M., Bolivar Osorio, F. J., Isaza-Ruiz, M., Xu, X., Vignarooban, K., Phelan, P., Inamuddin, & Kannan, A. M. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.09.126 · Cited by 1,522
Li, Z., Lu, Y., Huang, R., Chang, J., Yu, X., Jiang, R., Yu, X., & Roskilly, A. P. (2021) · Applied Energy · doi:10.1016/j.apenergy.2020.116277 · Cited by 342
Achkari, O., & El Fadar, A. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114806 · Cited by 341
Prieto, C., & Cabeza, L. F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113646 · Cited by 245
“[13] performed a theoretical study of the use of packed bed PCM in a cascade system.”
BackgroundLi, D., Wang, J., Ding, Y., Yao, H., & Huang, Y. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.040 · Cited by 186
Han, D., Guene Lougou, B., Xu, Y., Shuai, Y., & Huang, X. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114674 · Cited by 155
Tiari, S., Hockins, A., & Mahdavi, M. (2021) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2021.100999 · Cited by 122
Assessment of latent heat thermal storage systems operating with multiple phase change materials
N., L. N. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2019.04.008 · Cited by 113
Sunku Prasad, J., Muthukumar, P., Anandalakshmi, R., & Niyas, H. (2018) · Solar Energy · doi:10.1016/j.solener.2018.10.048 · Cited by 52
Overcharging of a cascaded packed bed thermal energy storage: Effects and solutions
Khor, J. O., Sze, J. Y., Li, Y., & Romagnoli, A. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109421 · Cited by 51
Metadata
- Authors
- Elfeky, K. E., Ahmed, N., & Wang, Q.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 139
- Pages
- 609-622
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2802741521
- Cited by
- 162
- References
- 0
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.