Cited by 64Refrigeration and Air Conditioning TechnologiesBuilding Energy and Comfort OptimizationIntegrated Energy Systems Optimization

Performance analysis of air source heat pump space heating system with an adaptive control for supply water temperature

Sun, Yuying, Chen, Xu, Wu, Shangjiang, Wei, Wenzhe, Wang, Wei, Deng, Shiming·2022·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2022.118401

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 31 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Sun, Y., Chen, X., Wu, S., Wei, W., Wang, W., & Deng, S.
Affiliations
  • Beijing University of Technology (CN)
  • Beijing Institute of Petrochemical Technology (CN)
  • Qatar University (QA)
Corresponding author
  • Wei, Wenzhe
  • Wang, Wei
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2022-07
Volume
211
Pages
118401
ISSN
1359-4311 (ISSN-L)
OpenAlex
W4221040060
Cited by
64
References
31
Citations by year
2026: 10 · 2025: 14 · 2024: 17 · 2023: 9 · 2022: 14
FWCI
5.09
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Thermal Engineering (publishedVersion)
  • Qatar University QSpace (Qatar University) (submittedVersion)
Funders
Beijing Natural Science Foundation
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
Keywords
air-source heat pump, space heating, adaptive control, coefficient of performance, building energy consumption, heating load, least squares estimation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review