Liquid cooling of data centers: A necessity facing challenges
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The evolving data generation landscape requires faster and more efficient microprocessors, prompting innovative manufacturing methods for smaller and faster transistors. Transistor congestion and rising demand for parallel processing are pushing the thermal design power of microprocessors well beyond 280 W, a limit for air cooling, and are expected to surpass 700 W by 2025. Consequently, transitioning towards liquid cooling is necessary. This article is intended to serve as a comprehensive roadmap to understanding this shift. It covers four major liquid cooling techniques: indirect water cooling with rear door heat exchangers, direct liquid cooling using water blocks or evaporators, single-phase, and two-phase immersion cooling. Indirect water cooling with rear door heat exchangers is a simple water cooling adaptation for reducing the power consumption of existing air-cooled data centers, but it faces the same limitations as air cooling for high-power servers. With enhancements such as reduced hot air leakage, active rear door heat exchangers, and deployment in locations conducive to free cooling, this approach could provide highly efficient data centers for the foreseeable future. Direct liquid cooling is well suited to meet rising thermal design power demands with the highest heat transfer coefficient report of 25 W/cm 2 -K, using water-based manifold microjet impingement on die. Emerging technologies are new thermosyphon systems, on-die/on-lid refrigeration/impingement, two phase impingement, and on/in die microchannel cooling. Air cooling is still required for peripheral equipment in this method, adding to the complexity and power consumption. Immersion cooling has the potential of reducing infrastructure size by one-third of air cooled data centers. Single-phase immersion cooling, while the most simple to implement, is limited by the low thermophysical properties of the dielectric liquids, and lack of flow control mechanism. In contrast, two-phase immersion cooling faces significant challenges related to the use of engineered fluids with global warming potential, health hazards, and long term reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recalibrating global data center energy-use estimates
Masanet, E., Shehabi, A., Lei, N., Smith, S., & Koomey, J. (2020) · Science · doi:10.1126/science.aba3758 · Cited by 1,545
Historical and current usage of per- and polyfluoroalkyl substances (PFAS): A literature review
Gaines, L. G. T. (2023) · American Journal of Industrial Medicine · doi:10.1002/ajim.23362 · Cited by 665
Usage impact on data center electricity needs: A system dynamic forecasting model
Koot, M., & Wijnhoven, F. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116798 · Cited by 403
Assessing the environmental impact of data centres part 1: Background, energy use and metrics
Whitehead, B., Andrews, D., Shah, A., & Maidment, G. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.021 · Cited by 165
Cited by
Ahmadi, V. E., Barestrand, H. A., Summers, J., & Yilmaz, C. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.107650 · Cited by 10
Metadata
- Authors
- Azarifar, M., Arik, M., & Chang, J.-Y.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2024-06
- Volume
- 247
- Pages
- 123112
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W4393970080
- Cited by
- 224
- References
- 4
- FWCI
- 30.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid cooling of data centers: A necessity facing challenges. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2024.123112
- The paper
- Azarifar, M., Arik, M., & Chang, J.-Y. (2024). Liquid cooling of data centers: A necessity facing challenges. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2024.123112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.