Liquid cooling of data centers: A necessity facing challenges
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The evolving data generation landscape requires faster and more efficient microprocessors, prompting innovative manufacturing methods for smaller and faster transistors. Transistor congestion and rising demand for parallel processing are pushing the thermal design power of microprocessors well beyond 280 W, a limit for air cooling, and are expected to surpass 700 W by 2025. Consequently, transitioning towards liquid cooling is necessary. This article is intended to serve as a comprehensive roadmap to understanding this shift. It covers four major liquid cooling techniques: indirect water cooling with rear door heat exchangers, direct liquid cooling using water blocks or evaporators, single-phase, and two-phase immersion cooling. Indirect water cooling with rear door heat exchangers is a simple water cooling adaptation for reducing the power consumption of existing air-cooled data centers, but it faces the same limitations as air cooling for high-power servers. With enhancements such as reduced hot air leakage, active rear door heat exchangers, and deployment in locations conducive to free cooling, this approach could provide highly efficient data centers for the foreseeable future. Direct liquid cooling is well suited to meet rising thermal design power demands with the highest heat transfer coefficient report of 25 W/cm 2 -K, using water-based manifold microjet impingement on die. Emerging technologies are new thermosyphon systems, on-die/on-lid refrigeration/impingement, two phase impingement, and on/in die microchannel cooling. Air cooling is still required for peripheral equipment in this method, adding to the complexity and power consumption. Immersion cooling has the potential of reducing infrastructure size by one-third of air cooled data centers. Single-phase immersion cooling, while the most simple to implement, is limited by the low thermophysical properties of the dielectric liquids, and lack of flow control mechanism. In contrast, two-phase immersion cooling faces significant challenges related to the use of engineered fluids with global warming potential, health hazards, and long term reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-performance heat sinking for VLSI
Tuckerman, D. B., & Pease, R. F. W. (1981) · IEEE Electron Device Letters · doi:10.1109/edl.1981.25367 · Cited by 5,291
Recalibrating global data center energy-use estimates
Masanet, E., Shehabi, A., Lei, N., Smith, S., & Koomey, J. (2020) · Science · doi:10.1126/science.aba3758 · Cited by 1,545
How to stop data centres from gobbling up the world’s electricity
Jones, N. (2018) · Nature · doi:10.1038/d41586-018-06610-y · Cited by 1,166
A critical review of traditional and emerging techniques and fluids for electronics cooling
Sohel Murshed, S. M., & Nieto de Castro, C. A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.112 · Cited by 987
Lighthill, S. J. (1978) · Journal of Sound and Vibration · doi:10.1016/0022-460x(78)90388-7 · Cited by 928
The next generation of refrigerants – Historical review, considerations, and outlook
Calm, J. M. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.01.013 · Cited by 834
On-chip cooling by superlattice-based thin-film thermoelectrics
Chowdhury, I., Prasher, R., Lofgreen, K., Chrysler, G., Narasimhan, S., Mahajan, R., Koester, D., Alley, R., & Venkatasubramanian, R. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2008.417 · Cited by 821
Habibi Khalaj, A., & Halgamuge, S. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.037 · Cited by 707
Historical and current usage of per- and polyfluoroalkyl substances (PFAS): A literature review
Gaines, L. G. T. (2023) · American Journal of Industrial Medicine · doi:10.1002/ajim.23362 · Cited by 665
Immersion cooling for lithium-ion batteries – A review
Roe, C., Feng, X., White, G., Li, R., Wang, H., Rui, X., Li, C., Zhang, F., Null, V., Parkes, M., et al. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2022.231094 · Cited by 590
Limited options for low-global-warming-potential refrigerants
McLinden, M. O., Brown, J. S., Brignoli, R., Kazakov, A. F., & Domanski, P. A. (2017) · Nature Communications · doi:10.1038/ncomms14476 · Cited by 541
Usage impact on data center electricity needs: A system dynamic forecasting model
Koot, M., & Wijnhoven, F. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116798 · Cited by 403
The IBM System/360 Model 91: Machine Philosophy and Instruction-Handling
Anderson, D. W., Sparacio, F. J., & Tomasulo, R. M. (1967) · IBM Journal of Research and Development · doi:10.1147/rd.111.0008 · Cited by 302
A review of heat transfer and pressure drop characteristics of single and two-phase microchannels
Asadi, M., Xie, G., & Sunden, B. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.07.090 · Cited by 245
Water immersion cooling of high power density electronics
Birbarah, P., Gebrael, T., Foulkes, T., Stillwell, A., Moore, A., Pilawa-Podgurski, R., & Miljkovic, N. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.118918 · Cited by 242
Cooling Systems in Data Centers: State of Art and Emerging Technologies
Capozzoli, A., & Primiceri, G. (2015) · Energy Procedia · doi:10.1016/j.egypro.2015.12.168 · Cited by 238
Liu, Y., Wei, X., Xiao, J., Liu, Z., Xu, Y., & Tian, Y. (2020) · Global Energy Interconnection · doi:10.1016/j.gloei.2020.07.008 · Cited by 233
Best Practices for Data Centers: Lessons Learned from Benchmarking 22 Data Centers
Greenberg, S., Mills, E., Tschudi, B., & Rumsey, P. (2006) · Cited by 214
The immersion cooling technology: Current and future development in energy saving
Pambudi, N. A., Sarifudin, A., Firdaus, R. A., Ulfa, D. K., Gandidi, I. M., & Romadhon, R. (2022) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.02.059 · Cited by 208
Review of jet impingement cooling of electronic devices: Emerging role of surface engineering
Sarkar, S., Gupta, R., Roy, T., Ganguly, R., & Megaridis, C. M. (2023) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2023.123888 · Cited by 207
Zhang, Y., Shan, K., Li, X., Li, H., & Wang, S. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112991 · Cited by 190
Assessing the environmental impact of data centres part 1: Background, energy use and metrics
Whitehead, B., Andrews, D., Shah, A., & Maidment, G. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.021 · Cited by 165
A novel high performance, ultra thin heat sink for electronics
Escher, W., Michel, B., & Dimos Poulikakos, A. (2010) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2010.03.001 · Cited by 156
Study on the flow and heat transfer characteristics of pin-fin manifold microchannel heat sink
Pan, Y.-H., Zhao, R. J., Nian, Y., & Cheng, W.-L. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.122052 · Cited by 134
Role of refrigerant mixtures as alternatives to CFCs
Didion, D. A., & Bivens, D. B. (1990) · International Journal of Refrigeration · doi:10.1016/0140-7007(90)90071-4 · Cited by 133
A review on airflow distribution and management in data center
Lu, H., Zhang, Z., & Liu, Y. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.08.050 · Cited by 120
Heydari, A., Gharaibeh, A. R., Tradat, M. I., Soud, Q., Manaserh, Y. “. A., Radmard, V., Eslami, B., Rodriguez, J., & Sammakia, B. G. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122122 · Cited by 114
Cho, J., Lim, T., & Kim, B. S. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.08.012 · Cited by 113
Huang, Y., Ge, J., Chen, Y., & Zhang, C. (2023) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2023.124023 · Cited by 109
The global warming potential of near-surface emitted water vapour
Sherwood, S. C., Dixit, V. V., & Salomez, C. (2018) · Environmental Research Letters · doi:10.1088/1748-9326/aae018 · Cited by 106
Rajapaksha, L. (2006) · Energy Conversion and Management · doi:10.1016/j.enconman.2006.06.001 · Cited by 103
Molés, F., Navarro-Esbrí, J., Peris, B., Mota-Babiloni, A., & Kontomaris, K. K. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.04.083 · Cited by 102
Manifold microchannel heat sink topology optimisation
Gilmore, N., Timchenko, V., & Menictas, C. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2021.121025 · Cited by 101
Advances in piezotronic transistors and piezotronics
Wang, L., & Wang, Z. L. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101108 · Cited by 95
Statistical analysis for predicting location-specific data center PUE and its improvement potential
Lei, N., & Masanet, E. R. (2020) · Energy · doi:10.1016/j.energy.2020.117556 · Cited by 94
Li, Z., & Gariboldi, E. (2021) · Materials Today Energy · doi:10.1016/j.mtener.2021.100642 · Cited by 91
Enough hot air: the role of immersion cooling
Haghshenas, K., Setz, B., Blosch, Y., & Aiello, M. (2023) · Energy Informatics · doi:10.1186/s42162-023-00269-0 · Cited by 90
Temperature management in data centers: why some (might) like it hot
El-Sayed, N., Stefanovici, I. A., Amvrosiadis, G., Hwang, A. A., & Schroeder, B. (2012) · ACM SIGMETRICS Performance Evaluation Review · doi:10.1145/2318857.2254778 · Cited by 90
Research progress of the liquid cold plate cooling technology for server electronic chips: A review
Zhou, W., Dong, K., Sun, Q. F., Luo, W., Zhang, B., Guan, S., & Wang, G. (2022) · International Journal of Energy Research · doi:10.1002/er.7979 · Cited by 81
A critical review on the thermal management of data center for local hotspot elimination
Zhao, R., Du, Y., Yang, X., Zhou, Z., Wang, W., & Yang, X. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113486 · Cited by 69
Cost-Efficient Overclocking in Immersion-Cooled Datacenters
Jalili, M., Manousakis, I., Goiri, Í., Misra, P. A., Raniwala, A., Alissa, H. A., Ramakrishnan, B., Tuma, P. E., Belady, C. L., da Fontoura, M. F. M. C., et al. (2021) · ACM/IEEE International Symposium on Computer Architecture (ISCA) · doi:10.1109/isca52012.2021.00055 · Cited by 54
Application of the combined air-conditioning systems for energy conservation in data center
Priyadumkol, J., & Kittichaikarn, C. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.07.082 · Cited by 51
Recent Advances in Two-Phase Immersion Cooling with Surface Modifications for Thermal Management
Kang, D., Lee, J., Chakraborty, A., Lee, S.-E., Kim, G., & Yu, C. (2022) · Energies · doi:10.3390/en15031214 · Cited by 48
Introductory Chapter: Electronics Cooling — An Overview
Murshed, S. M. S. (2016) · InTech eBooks · doi:10.5772/63321 · Cited by 38
Embedded Microjets for Thermal Management of High Power-Density Electronic Devices
Walsh, S. M., Malouin, B. A., Browne, E. A., Bagnall, K. R., Wang, E. N., & Smith, J. P. (2018) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2867788 · Cited by 35
Souza, L. M. F., Camboim, K., & Alencar, F. (2022) · The Journal of Supercomputing · doi:10.1007/s11227-022-04515-2 · Cited by 19
Experimental Characterization of a Server-Level Thermosyphon for High-Heat Flux Dissipations
Amalfi, R. L., Cataldo, F., Marcinichen, J. B., & Thome, J. R. (2020) · I-THERM :/I-THERM - Intersociety Conference on Thermal Phenomena in Electronic Systems · doi:10.1109/itherm45881.2020.9190186 · Cited by 18
Shigemune, H., Pradidarcheep, K., Kuwajima, Y., Seki, Y., Maeda, S., & Cacucciolo, V. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202100004 · Cited by 15
Cited by
Kong, R., Zhang, H., Tang, M., Zou, H., Tian, C., & Ding, T. (2024) · Energy · doi:10.1016/j.energy.2024.132846 · Cited by 169
Ahmadi, V. E., Barestrand, H. A., Summers, J., & Yilmaz, C. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.107650 · Cited by 10
Metadata
- Authors
- Azarifar, M., Arik, M., & Chang, J.-Y.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2024-06
- Volume
- 247
- Pages
- 123112
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W4393970080
- Cited by
- 224
- References
- 48
- FWCI
- 30.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.