The DOI matches its Crossref record.
Investigation of electrocoagulation reactor design parameters effect on the removal of cadmium from synthetic and phosphate industrial wastewater
Open accessAbstract
This study investigates the effect of reactor design parameters on cadmium removal from industrial wastewater discharged by the Tunisian Chemical Group (TCG) to improve as much as possible efficiency and cost of electrocoagulation (EC) process. Based on an examination of the design parameters one by one, the best cadmium removal was achieved for an inter-electrode distance ( d ie ) of 0.5 cm, monopolar connection mode, stirring speed of 300 rev min −1 , surface-area-to-volume ratio ( S / V ) of 13.6 m −1 , and an initial temperature of 50 °C. These operating conditions are allowed to achieve efficient removal in a relatively short operating time with the lowest energy consumption and cost possible. The present study proved that the parameters that have an effect on the operating cost are the electrode configuration, inter-electrode distance and S / V ratio. The energy consumption, the pH evolution, and the treatment cost were studied. The investigation of the effect of all the selected optimum EC design parameters together on the removal of cadmium from the TCG wastewater proved that the treatment was highly efficient; 100% of cadmium removal was reached in 5 min, with a very low power consumption (1.6 kW h m −3 ) and very low cost (0.116 TND m −3 ). Moreover, EC was found to be capable of removing cadmium as well as other pollutants at the same time from the case-study industrial wastewater. The investigation carried out in this work explores and proposes a very cost-effective treatment method to remove heavy metals from industrial wastewater if compared to results reported about cost of this treatment process through other widely used technologies such as coagulation (4.36 Tunisian National Dinar (TND) m −3 ) and precipitation (9.96 TND m −3 ) employed in previous studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
Garcia-Segura, S., Eiband, M. M. S. G., de Melo, J. V., & Martínez-Huitle, C. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.07.047 · Cited by 740
Heavy metals removal from aqueous environments by electrocoagulation process– a systematic review
Bazrafshan, E., Mohammadi, L., Ansari-Moghaddam, A., & Mahvi, A. H. (2015) · Journal of Environmental Health Science and Engineering · doi:10.1186/s40201-015-0233-8 · Cited by 436
Recent progress on electrocoagulation process for wastewater treatment: A review
Das, P. P., Sharma, M., & Purkait, M. K. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2022.121058 · Cited by 312
Metadata
- Authors
- Khaled, B., Wided, B., Béchir, H., Elimame, E., Mouna, L., & Zied, T.
- Venue
- Arabian Journal of Chemistry
- Publisher
- Scientific Scholar
- Published
- 2019-12
- Volume
- 12
- Issue
- 8
- Pages
- 1848-1859
- ISSN
- 1878-5352 (ISSN-L)
- OpenAlex
- W2003503036
- Cited by
- 220
- References
- 0
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of electrocoagulation reactor design parameters effect on the removal of cadmium from synthetic and phosphate industrial wastewater. https://app.cochat.ai/papers/10.1016/j.arabjc.2014.12.012
- The paper
- Khaled, B., Wided, B., Béchir, H., Elimame, E., Mouna, L., & Zied, T. (2019). Investigation of electrocoagulation reactor design parameters effect on the removal of cadmium from synthetic and phosphate industrial wastewater. Arabian Journal of Chemistry. https://doi.org/10.1016/j.arabjc.2014.12.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.