The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Does the Position of the Femoral Tunnel Affect the Laxity or Clinical Outcome of the Anterior Cruciate Ligament–Reconstructed Knee? A Clinical, Prospective, Randomized, Double-Blind Study
Abstract
PURPOSE: The aim of this study was to evaluate whether a change in the femoral graft insertion site between the 1-o'clock (high) and 2-o'clock (low) positions could change the laxity, the score on the 2000 International Knee Documentation Committee (IKDC) Knee Examination Form, or the score on the 2000 subjective IKDC Knee Evaluation Form in the anterior cruciate ligament (ACL)-reconstructed knee. METHODS: The study was designed as a prospective, randomized, double-blind investigation. We randomized 30 patients to the low tunnel position group and 30 to the high tunnel position group. Four-stranded semitendinosus and gracilis single-bundle grafts were used. At follow-up, the patients were examined according to the IKDC evaluation form and the IKDC examination form. The exact measurements of laxity at 25 degrees and 70 degrees were performed by use of the Rolimeter (Aircast, Boca Raton, FL). Standardized radiographs were evaluated. RESULTS: In total, 26 patients in the low tunnel position group and 25 in the high tunnel position group completed the study. At follow-up, we found no significant difference in the laxity at 25 degrees and 70 degrees or scores on the IKDC examination form. We found a significant difference in the scores on the IKDC evaluation form, favoring the low position, with a subjective score of 82.8 versus 70.4. CONCLUSIONS: A change in the femoral tunnel placement from 1 o'clock to 2 o'clock did not result in a detectable change in the sagittal laxity at 25 degrees and 70 degrees , on the pivot-shift test, or on the IKDC examination form scores. However, we found a significant difference between the two groups in the scores on the IKDC evaluation form, most evident in the subgroups dealing with the patient's subjective knee stability. We conclude that it is possible to improve the clinical result in 1-bundle ACL reconstruction by lowering the tibial tunnel angle and thereby lowering the femoral tunnel toward the 2-o'clock position. LEVEL OF EVIDENCE: Level I, therapeutic prospective randomized trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amis, A., & Dawkins, G. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b2.2005151 · Cited by 731
Cited by
Forsythe, B., Kopf, S., Wong, A. K., Martins, C. A., Anderst, W., Tashman, S., & Fu, F. H. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.00654 · Cited by 336
Metadata
- Authors
- Jepsen, C. F., Lundberg-Jensen, A. K., & Faunoe, P.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2007-12
- Volume
- 23
- Issue
- 12
- Pages
- 1326-1333
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2069443675
- Cited by
- 177
- References
- 1
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does the Position of the Femoral Tunnel Affect the Laxity or Clinical Outcome of the Anterior Cruciate Ligament–Reconstructed Knee? A Clinical, Prospective, Randomized, Double-Blind Study. https://app.cochat.ai/papers/10.1016/j.arthro.2007.09.010
- The paper
- Jepsen, C. F., Lundberg-Jensen, A. K., & Faunoe, P. (2007). Does the Position of the Femoral Tunnel Affect the Laxity or Clinical Outcome of the Anterior Cruciate Ligament–Reconstructed Knee? A Clinical, Prospective, Randomized, Double-Blind Study. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2007.09.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.