CoChat

Does Autologous Leukocyte-Platelet–Rich Plasma Improve Tendon Healing in Arthroscopic Repair of Large or Massive Rotator Cuff Tears?

Charousset, Christophe, Zaoui, Amine, Bellaïche, Laurence, Piterman, Michel · 2014 · Arthroscopy: The Journal of Arthroscopic & Related Surgery
Cited by 86

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the clinical and magnetic resonance imaging (MRI) outcome of arthroscopic rotator cuff repair with the use of leukocyte-platelet-rich plasma (L-PRP) in patients with large or massive rotator cuff tears. METHODS: A comparative cohort of patients with large or massive rotator cuff tears undergoing arthroscopic repair was studied. Two consecutive groups of patients were included: rotator cuff repairs with L-PRP injection (group 1, n = 35) and rotator cuff repairs without L-PRP injection (group 2, n = 35). A double-row cross-suture cuff repair was performed by a single surgeon with the same rehabilitation protocol. Patients were clinically evaluated with the Constant score; Simple Shoulder Test score; University of California, Los Angeles (UCLA) score; and strength measurements by use of a handheld dynamometer. Rotator cuff healing was evaluated by postoperative MRI using the Sugaya classification (type 1 to type 5). RESULTS: We prospectively evaluated the 2 groups at a minimum 2-year follow-up. The results did not show differences in cuff healing between the 2 groups (P = .16). The size of recurrent tears (type 4 v type 5), however, was significantly smaller in group 1 (P = .008). There was no statistically significant difference in the recurrent tear rate (types 4 and 5) between the 2 groups (P = .65). There was no significant difference between group 1 and group 2 in terms of University of California, Los Angeles score (29.1 and 30.3, respectively; P = .90); Simple Shoulder Test score (9.9 and 10.2, respectively; P = .94); Constant score (77.3 and 78.1, respectively; P = .82); and strength (7.5 and 7.0, respectively; P = .51). CONCLUSIONS: In our study the use of autologous L-PRP did not improve the quality of tendon healing in patients undergoing arthroscopic repair of large or massive rotator cuff tears based on postoperative MRI evaluation. The only significant advantage was that the L-PRP patients had smaller iterative tears. However, the functional outcome was similar in the 2 groups of patients. LEVEL OF EVIDENCE: Level III, case-control study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2013.12.018

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 86

Metadata

Authors
Charousset, C., Zaoui, A., Bellaïche, L., & Piterman, M.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2014-04
Volume
30
Issue
4
Pages
428-435
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2056295443
Cited by
86
References
4
FWCI
12.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.