Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND After several years of treatment, patients with Parkinson's disease (PD) tend to have, as a side effect of the medication, dyskinesias. Close monitoring may benefit patients by enabling doctors to tailor a personalised medication regimen. Moreover, dyskinesia monitoring can help neurologists make more informed decisions in patient's care. OBJECTIVE To design and validate an algorithm able to be embedded into a system that PD patients could wear during their activities of daily living with the purpose of registering the occurrence of dyskinesia in real conditions. MATERIALS AND METHODS Data from an accelerometer positioned in the waist are collected at the patient's home and are annotated by experienced clinicians. Data collection is divided into two parts: a main database gathered from 92 patients used to partially train and to evaluate the algorithms based on a leave-one-out approach and, on the other hand, a second database from 10 patients which have been used to also train a part of the detection algorithm. RESULTS Results show that, depending on the severity and location of dyskinesia, specificities and sensitivities higher than 90% are achieved using a leave-one-out methodology. Although mild dyskinesias presented on the limbs are detected with 95% specificity and 39% sensitivity, the most important types of dyskinesia (any strong dyskinesia and trunk mild dyskinesia) are assessed with 95% specificity and 93% sensitivity. CONCLUSION The presented algorithmic method and wearable device have been successfully validated in monitoring the occurrence of strong dyskinesias and mild trunk dyskinesias during activities of daily living.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 1×
“The pathology of the disease is characterised by an insufficient activity in the neurons that produce dopamine, one of the main neurotransmitters involved in the control of movement [1].”
BackgroundA survey of cross-validation procedures for model selection
Arlot, S., & Celisse, A. (2010) · Statistics Surveys · doi:10.1214/09-ss054 · Cited by 3,522
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“Dyskinesia band covers until 4 Hz since, although other studies consider 8 Hz to be the limit, frequencies higher than 4 Hz correspond to tremor according to a consensus of the Movement Disorders Society [31].”
BackgroundA Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“[23,24] argue that placing an accelerometer on the waist is interesting from a mechanical point of view, because of the closeness and solidarity with the centre of mass of the human body, providing good ergonomics for the patient.”
BackgroundMonitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
A frequency and correlation analysis of motor deficits in Parkinson patients
Nieuwboer, A., Weerdt, W. D., Dom, R., & Lesaffre, E. (1998) · Disability and Rehabilitation · doi:10.3109/09638289809166074 · Cited by 175
Cited by
Halilaj, E., Rajagopal, A., Fiterau, M., Hicks, J. L., Hastie, T. J., & Delp, S. L. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.09.009 · Cited by 460
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Teleneurology and mobile technologies: the future of neurological care
Dorsey, E. R., Glidden, A. M., Holloway, M. R., Birbeck, G. L., & Schwamm, L. H. (2018) · Nature Reviews Neurology · doi:10.1038/nrneurol.2018.31 · Cited by 258
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Self-citationOnline human activity recognition using low-power wearable devices
Bhat, G., Deb, R., Chaurasia, V. V., Shill, H., & Ogras, U. Y. (2018) · Proceedings of the International Conference on Computer-Aided Design · doi:10.1145/3240765.3240833 · Cited by 82
“As soon as the patient leaves the clinic, there is no way to continuously monitor the patient and report potential problems [13, 27].”
Background
Metadata
- Authors
- Pérez-López, C., Samà, A., Rodríguez-Martín, D., Moreno-Aróstegui, J. M., Cabestany, J., Bayes, A., Mestre, B., Alcaine, S., Quispe, P., Laighin, G. Ó., Sweeney, D., Quinlan, L. R., Counihan, T. J., Browne, P., Annicchiarico, R., Costa, A., Lewy, H., & Rodríguez-Molinero, A.
- Venue
- Artificial Intelligence in Medicine
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 67
- Pages
- 47-56
- ISSN
- 0933-3657 (ISSN-L)
- OpenAlex
- W2270659945
- Cited by
- 65
- References
- 7
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer. https://app.cochat.ai/papers/10.1016/j.artmed.2016.01.001
- The paper
- Pérez-López, C., Samà, A., Rodríguez-Martín, D., Moreno-Aróstegui, J. M., Cabestany, J., Bayes, A., Mestre, B., Alcaine, S., Quispe, P., Laighin, G. Ó., Sweeney, D., Quinlan, L. R., Counihan, T. J., Browne, P., Annicchiarico, R., Costa, A., Lewy, H., & Rodríguez-Molinero, A. (2016). Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer. Artificial Intelligence in Medicine. https://doi.org/10.1016/j.artmed.2016.01.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.