Automated detection of schizophrenia using nonlinear signal processing methods
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Examination of the brain's condition with the Electroencephalogram (EEG) can be helpful to predict abnormality and cerebral activities. The purpose of this study was to develop an Automated Diagnostic Tool (ADT) to investigate and classify the EEG signal patterns into normal and schizophrenia classes. The ADT implements a sequence of events, such as EEG series splitting, non-linear features mining, t-test assisted feature selection, classification and validation. The proposed ADT is employed to evaluate a 19-channel EEG signal collected from normal and schizophrenia class volunteers. A dataset was created by splitting the raw 19-channel EEG into a sequence of 6250 sample points, which was helpful to produce 1142 features of normal and schizophrenia class patterns. Non-linear feature extraction was then implemented to mine 157 features from each EEG pattern, from which 14 of the principal features were identified based on significance. Finally, a signal classification practice with Decision-Tree (DT), Linear-Discriminant analysis (LD), k-Nearest-Neighbour (KNN), Probabilistic-Neural-Network (PNN), and Support-Vector-Machine (SVM) with various kernels was implemented. The experimental outcome showed that the SVM with Radial-Basis-Function (SVM-RBF) offered a superior average performance value of 92.91% on the considered EEG dataset, as compared to other classifiers implemented in this work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Bhattacharyya, A., Sharma, M., Pachori, R. B., Sircar, P., & Acharya, U. R. (2018) · Neural Computing and Applications · doi:10.1007/s00521-016-2646-4 · Cited by 204 · cited 1×
“The K-Nearest Neighbour (KNN) is another classi fi er that was considered in this work [44].”
Self-citationRetractedA Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“After acquisition, the signals were pre-processed using EGGLAB [24], after which 16 time-domain features and four frequency-domain features were extracted per electrode, for each participant.”
Possible generalization of Boltzmann-Gibbs statistics
Tsallis, C. (1988) · Journal of Statistical Physics · doi:10.1007/bf01016429 · Cited by 9,589 · cited 1×
“…Lyapunov exponent(lx) [30], Kolmogorov-Sinai(k-s) entropy [31], Hjorth complexity(hc) and mobility(hm) [32,33], Rényi(re) [34], Shannon(sn) [35], Tsallis(ts) [36], Kolmogorov complexity(kc) [37], bispectrum (entropy 1, 2 and phase)(bs) [38], cumulant(c) [39] and permutation entropy(pe) [40].”
An introduction to variable and feature selection
GuyonIsabelle, & ElisseeffAndré (2003) · Journal of Machine Learning Research · doi:10.5555/944919.944968 · Cited by 7,715
An Introduction to Variable and Feature Selection.
Guyon, I., & Elisseeff, A. (2003) · Cited by 6,576
Cognitive Architecture and Instructional Design
Sweller, J., van Merrienboer, J. J. G., & Paas, F. G. W. C. (1998) · Educational Psychology Review · doi:10.1023/a:1022193728205 · Cited by 6,023
Permutation Entropy: A Natural Complexity Measure for Time Series
Bandt, C., & Pompe, B. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.174102 · Cited by 4,867 · cited 1×
“…Lyapunov exponent(lx) [30], Kolmogorov-Sinai(k-s) entropy [31], Hjorth complexity(hc) and mobility(hm) [32,33], Rényi(re) [34], Shannon(sn) [35], Tsallis(ts) [36], Kolmogorov complexity(kc) [37], bispectrum (entropy 1, 2 and phase)(bs) [38], cumulant(c) [39] and permutation entropy(pe) [40].”
On Measures of Entropy and Information
Rényi, A. (1961) · Project Euclid (Cornell University) · Cited by 4,031
Recurrence plots for the analysis of complex systems
MARWAN, N., CARMENROMANO, M., THIEL, M., & KURTHS, J. (2007) · Physics Reports · doi:10.1016/j.physrep.2006.11.001 · Cited by 3,814 · cited 1×
“3 shows the sample recurrence plots [47 – 50] for (a) normal and (b) sz EEG signals.”
Cited by
A Computerized Method for Automatic Detection of Schizophrenia Using EEG Signals
Siuly, S., Khare, S. K., Bajaj, V., Wang, H., & Zhang, Y. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3022715 · Cited by 203
“Jahmunah et al. [19] developed a deep learning scheme extracting 157 nonlinear features from both SZ and HC EEG signals.”
Automatic Diagnosis of Schizophrenia in EEG Signals Using CNN-LSTM Models
Shoeibi, A., Sadeghi, D., Moridian, P., Ghassemi, N., Heras, J., Alizadehsani, R., Khadem, A., Kong, Y., Nahavandi, S., Zhang, Y.-D., et al. (2021) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2021.777977 · Cited by 197
“In recent years, various investigations have provided automated SZ diagnosis via EEG signals using artificial intelligence (AI) methods (Prasad et al., 2013; Shim et al., 2016; Chu et al., 2017; Alimardani et al., 2018; Devia et al., 2019; Jahmunah et al., 2019; Li et al., 2019; Naira and Alamo, 2019; Oh et al., 2019;…”
Artificial Intelligence Techniques for Automated Diagnosis of Neurological Disorders
Raghavendra, U., Acharya, U. R., & Adeli, H. (2019) · European Neurology · doi:10.1159/000504292 · Cited by 174
Self-citationShalbaf, A., Bagherzadeh, S., & Maghsoudi, A. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00925-9 · Cited by 160
Chen, Z., Liu, X., Yang, Q., Wang, Y.-J., Miao, K., Gong, Z., Yu, Y., Leonov, A., Liu, C., Feng, Z., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.1671 · Cited by 43
Chen, Z., Hu, B., Liu, X., Becker, B., Eickhoff, S. B., Miao, K., Gu, X., Tang, Y., Dai, X., Li, C., et al. (2023) · BMC Medicine · doi:10.1186/s12916-023-02941-4 · Cited by 35
Metadata
- Authors
- Jahmunah, V., Lih Oh, S., Rajinikanth, V., Ciaccio, E. J., Hao Cheong, K., Arunkumar, N., & Acharya, U. R.
- Venue
- Artificial Intelligence in Medicine
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 100
- Pages
- 101698
- ISSN
- 0933-3657 (ISSN-L)
- OpenAlex
- W2962865354
- Cited by
- 238
- References
- 47
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.