A Computerized Method for Automatic Detection of Schizophrenia Using EEG Signals
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Diagnosis of schizophrenia (SZ) is traditionally performed through patient's interviews by a skilled psychiatrist. This process is time-consuming, burdensome, subject to error and bias. Hence the aim of this study is to develop an automatic SZ identification scheme using electroencephalogram (EEG) signals that can eradicate the aforementioned problems and support clinicians and researchers. This study introduces a methodology design involving empirical mode decomposition (EMD) technique for diagnosis of SZ from EEG signals to perfectly handle the behavior of non-stationary and nonlinear EEG signals. In this study, each EEG signal is decomposed into intrinsic mode functions (IMFs) by the EMD algorithm and then twenty-two statistical characteristics/features are calculated from these IMFs. Among them, five features are selected as significant feature applying Kruskal Wallis test. The performance of the obtained feature set is tested through several renowned classifierson a SZ EEG dataset. Among the considered classifiers, theensemble bagged tree performed as the best classifier producing 93.21% correct classification rate for SZ, with an overall accuracy of 89.59% for IMF 2. These results indicate that EEG signals discriminate SZ patients from healthy control (HC) subjects efficiently and have the potential to become a tool for the psychiatrist to support the positive diagnosis of SZ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vos, T., Abajobir, A. A., Abate, K. H., Abbafati, C., Abbas, K. M., Abd-Allah, F., Abdulkader, R. S., Abdulle, A. M., Abebo, T. A., Abera, S. F., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32154-2 · Cited by 13,220
Excess early mortality in schizophrenia.
Laursen, T. M., Nordentoft, M., & Mortensen, P. B. (2014) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032813-153657 · Cited by 913 · cited 1×
“The expected death of the SZ patients are 2-3 times higher than normal healthy people because of preventable physical diseases, such as cardiovascular disease, metabolic disease and infections [4].”
BackgroundNonlinear feature based classification of speech under stress.
Zhou, G., Hansen, J. H. L., & Kaiser, J. F. (2001) · IEEE Transactions on Speech and Audio Processing · doi:10.1109/89.905995 · Cited by 409
Did I do that? Abnormal predictive processes in schizophrenia when button pressing to deliver a tone
Ford, J. M., Palzes, V. A., Roach, B. J., & Mathalon, D. H. (2014) · Schizophrenia Bulletin · doi:10.1093/schbul/sbt072 · Cited by 210
Cited by
Chen, Z., Liu, X., Yang, Q., Wang, Y.-J., Miao, K., Gong, Z., Yu, Y., Leonov, A., Liu, C., Feng, Z., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.1671 · Cited by 43
Chen, Z., Hu, B., Liu, X., Becker, B., Eickhoff, S. B., Miao, K., Gu, X., Tang, Y., Dai, X., Li, C., et al. (2023) · BMC Medicine · doi:10.1186/s12916-023-02941-4 · Cited by 35
Metadata
- Authors
- Siuly, S., Khare, S. K., Bajaj, V., Wang, H., & Zhang, Y.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2020-11
- Volume
- 28
- Issue
- 11
- Pages
- 2390-2400
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W3084085040
- Cited by
- 203
- References
- 4
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Computerized Method for Automatic Detection of Schizophrenia Using EEG Signals. https://app.cochat.ai/papers/10.1109/tnsre.2020.3022715
- The paper
- Siuly, S., Khare, S. K., Bajaj, V., Wang, H., & Zhang, Y. (2020). A Computerized Method for Automatic Detection of Schizophrenia Using EEG Signals. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2020.3022715
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.