CoChat

ECG-based multi-class arrhythmia detection using spatio-temporal attention-based convolutional recurrent neural network

Zhang, Jing, Liu, Aiping, Gao, Min, Chen, Xiang, Zhang, Xu, Chen, Xun · 2020 · Artificial Intelligence in Medicine
Cited by 192

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Automatic arrhythmia detection based on electrocardiogram (ECG) is of great significance for early prevention and diagnosis of cardiac diseases. Recently, deep learning methods have been applied to arrhythmia detection and obtained great success. Among them, convolutional neural network (CNN) is an effective method for extracting features due to its local connectivity and parameter sharing. In addition, recurrent neural network (RNN) is another commonly used method, which is applied to process time-series signal. The stacking of both CNN and RNN has been proved to be more effective in multi-class arrhythmia detection. However, these networks ignored the fact that different channels and temporal segments of a feature map extracted from the 12-lead ECG signal contribute differently to cardiac arrhythmia detection, and thus, the classification performance could be greatly improved. To address this issue, spatio-temporal attention-based convolutional recurrent neural network (STA-CRNN) is proposed to focus on representative features along both spatial and temporal axes. STA-CRNN consists of CNN subnetwork, spatio-temporal attention modules and RNN subnetwork. The experiment result shows that, STA-CRNN reaches an average F1 score of 0.835 in classifying 8 types of arrhythmias and normal rhythm. Compared with the state-of-the-art methods based on the same public dataset, STA-CRNN achieves an obvious improvement on identifying most of arrhythmias. Also, it is demonstrated by visualization that the learned features through STA-CRNN are in line with clinical judgement. STA-CRNN provides a promising method for automatic arrhythmia detection, which has a potential to assist cardiologists in the diagnosis of arrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.artmed.2020.101856

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 192

Metadata

Authors
Zhang, J., Liu, A., Gao, M., Chen, X., Zhang, X., & Chen, X.
Venue
Artificial Intelligence in Medicine
Publisher
Elsevier BV
Published
2020-06
Volume
106
Pages
101856
ISSN
0933-3657 (ISSN-L)
OpenAlex
W3022945091
Cited by
192
References
7
FWCI
13.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG-based multi-class arrhythmia detection using spatio-temporal attention-based convolutional recurrent neural network. https://app.cochat.ai/papers/10.1016/j.artmed.2020.101856
The paper
Zhang, J., Liu, A., Gao, M., Chen, X., Zhang, X., & Chen, X. (2020). ECG-based multi-class arrhythmia detection using spatio-temporal attention-based convolutional recurrent neural network. Artificial Intelligence in Medicine. https://doi.org/10.1016/j.artmed.2020.101856

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.