Abstract
A high resolution air quality monitoring campaign (PM, CO2 and CO) was conducted on differently designed station platforms in the Barcelona subway system under: (a) normal forced tunnel ventilation, and (b) with daytime tunnel ventilation systems shut down. PM concentrations are highly variable (6–128 μgPM1 m−3, 16–314 μgPM3 m−3, and 33–332 μgPM10 m−3, 15-min averages) depending on ventilation conditions and station design. Narrow platforms served by single-track tunnels are heavily dependent on forced tunnel ventilation and cannot rely on the train piston effect alone to reduce platform PM concentrations. In contrast PM levels in stations with spacious double-track tunnels are not greatly affected when tunnel ventilation is switched off, offering the possibility of significant energy savings without damaging air quality. Sampling at different positions along the platform reveals considerable lateral variation, with the greatest accumulation of particulates occurring at one end of the platform. Passenger accesses can dilute PM concentrations by introducing cleaner outside air, although lateral down-platform accesses are less effective than those positioned at the train entry point. CO concentrations on the platform are very low (≤1 ppm) and probably controlled by ingress of traffic-contaminated street-level air. CO2 averages range from 371 to 569 ppm, changing during the build-up and exchange of passengers with each passing train.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Factors controlling air quality in different European subway systems
Martins, V., Moreno, T., Mendes, L., Eleftheriadis, K., Diapouli, E., Alves, C. A., Duarte, M., de Miguel, E., Capdevila, M., Querol, X., et al. (2016) · Environmental Research · doi:10.1016/j.envres.2015.12.007 · Cited by 194
Self-citationAir quality inside subway metro indoor environment worldwide: A review
Xu, B., & Hao, J. (2017) · Environment International · doi:10.1016/j.envint.2017.06.016 · Cited by 167
“5 levels (11–32 μg m−3) inside the trains in summer were the lowest among worldwide metro systems due to the air conditioning system working in all carriages (Moreno et al., 2014b).”
BackgroundParticulate matter and the airway epithelium: the special case of the underground?
Cooper, D. M., & Loxham, M. (2019) · European Respiratory Review · doi:10.1183/16000617.0066-2019 · Cited by 80
Metadata
- Authors
- Moreno, T., Pérez, N., Reche, C., Martins, V., de Miguel, E., Capdevila, M., Centelles, S., Minguillón, M. C., Amato, F., Alastuey, A., Querol, X., & Gibbons, W.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2014-08
- Volume
- 92
- Pages
- 461-468
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W2078913624
- Cited by
- 194
- References
- 0
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subway platform air quality: Assessing the influences of tunnel ventilation, train piston effect and station design. https://app.cochat.ai/papers/10.1016/j.atmosenv.2014.04.043
- The paper
- Moreno, T., Pérez, N., Reche, C., Martins, V., de Miguel, E., Capdevila, M., Centelles, S., Minguillón, M. C., Amato, F., Alastuey, A., Querol, X., & Gibbons, W. (2014). Subway platform air quality: Assessing the influences of tunnel ventilation, train piston effect and station design. Atmospheric Environment. https://doi.org/10.1016/j.atmosenv.2014.04.043