A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This research presents a novel hand exoskeleton rehabilitation device to facilitate tendon therapy exercises. The exoskeleton is designed to assist fingers flexion and extension motions in a natural manner. The proposed multi-Degree Of Freedom (DOF) system consists of a direct-driven, optimized and underactuated serial linkage mechanism having capability to exert extremely high force levels perpendicularly on the finger phalanges. Kinematic and dynamic models of the proposed device have been derived. The device design is based on the results of multi-objective optimization algorithm and series of experiments conducted to study capabilities of the human hand. To permit a user-friendly interaction with the device, the control is based on minimum jerk trajectory generation. Using this control system, the transient response and steady state behavior of the proposed device are analyzed after designing and fabricating a two-fingered prototype. The pilot study shows that the proposed rehabilitation system is capable of flexing and extending the fingers with accurate trajectories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335
Self-citation
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
A Review of Active Hand Exoskeletons for Rehabilitation and Assistance
du Plessis, T., Djouani, K., & Oosthuizen, C. (2021) · Robotics · doi:10.3390/robotics10010040 · Cited by 218
“Encoders such as optical or magnetic (hall-effect) encoders are generally used on the electric motors themselves to track the revolutions per minute (rpm) or position of the output device [43,44,56,85].”
BackgroundInfluentialA Helping Hand: Soft Orthosis with Integrated Optical Strain Sensors and EMG Control
Zhao, H., Jalving, J., Huang, R., Knepper, R., Ruina, A., & Shepherd, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582216 · Cited by 191
“To ensure safety and to reduce control complexity, some orthoses use mechanical compliances [4], [5] such as underactuated linkages [6] or low-stiffness materials and structures (e.”
Soft Wearable Skin-Stretch Device for Haptic Feedback Using Twisted and Coiled Polymer Actuators
Chossat, J.-B., Chen, D. K. Y., Park, Y.-L., & Shull, P. B. (2019) · IEEE Transactions on Haptics · doi:10.1109/toh.2019.2943154 · Cited by 73
“Even when significant efforts are invested in designing miniature devices [12], [13], such a design often results in somewhat bulky devices that compromise the user natural interaction with the world.”
Background
Metadata
- Authors
- Iqbal, J., Khan, H., Tsagarakis, N. G., & Caldwell, D. G.
- Venue
- Biocybernetics and Biomedical Engineering
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 34
- Issue
- 2
- Pages
- 79-89
- ISSN
- 0208-5216 (ISSN-L)
- OpenAlex
- W2002238231
- Cited by
- 141
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping. https://app.cochat.ai/papers/10.1016/j.bbe.2014.01.003
- The paper
- Iqbal, J., Khan, H., Tsagarakis, N. G., & Caldwell, D. G. (2014). A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping. Biocybernetics and Biomedical Engineering. https://doi.org/10.1016/j.bbe.2014.01.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.