A Review of Active Hand Exoskeletons for Rehabilitation and Assistance
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Disabilities are a global issue due to the decrease in life quality and mobility of patients, especially people suffering from hand disabilities. This paper presents a review of active hand exoskeleton technologies, over the past decade, for rehabilitation, assistance, augmentation, and haptic devices. Hand exoskeletons are still an active research field due to challenges that engineers face and are trying to solve. Each hand exoskeleton has certain requirements to fulfil to achieve their aims. These requirements have been extracted and categorized into two sections: general and specific, to give a common platform for developing future devices. Since this is still a developing area, the requirements are also shaped according to the advances in the field. Technical challenges, such as size requirements, weight, ergonomics, rehabilitation, actuators, and sensors are all due to the complex anatomy and biomechanics of the hand. The hand is one of the most complex structures in the human body; therefore, to understand certain design approaches, the anatomy and biomechanics of the hand are addressed in this paper. The control of these devices is also an arising challenge due to the implementation of intelligent systems and new rehabilitation techniques. This includes intention detection techniques (electroencephalography (EEG), electromyography (EMG), admittance) and estimating applied assistance. Therefore, this paper summarizes the technology in a systematic approach and reviews the state of the art of active hand exoskeletons with a focus on rehabilitation and assistive devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langhorne, P., Bernhardt, J., & Kwakkel, G. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60325-5 · Cited by 2,726
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206 · cited 2×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodSoft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617 · cited 5×
“contracts when inflated and vice versa [50,54].”
BackgroundInfluentialTHE PREHENSILE MOVEMENTS OF THE HUMAN HAND
Napier, J. R. (1956) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.38b4.902 · Cited by 1,571 · cited 1×
“Therefore, the main and most used grips can be classified into three main categories namely Power, Precision, and Hook grips [28,29].”
BackgroundLum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 2×
“that highly repetitive task training can help the recovery of motor functions [10,11].”
BackgroundThe GRASP Taxonomy of Human Grasp Types
Feix, T., Romero, J., Schmiedmayer, H.-B., Dollar, A. M., & Kragic, D. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2470657 · Cited by 1,024 · cited 1×
“Therefore, the main and most used grips can be classified into three main categories namely Power, Precision, and Hook grips [28,29].”
BackgroundThe Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 2×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodCurrent hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473 · cited 3×
“[47] 2015 Exo-Glove Assistance Tendon/cable (Underactuated) Complaint 40 N Flex/Extend 194 g hand Yes Wrist motion No”
BackgroundSoft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320 · cited 1×
“The author recommends reading [3,15–21] articles that capture other information regarding the technology surrounding hand exoskeletons especially [3,20,21]; these papers focus on soft robotic technologies including artificial muscles and tendon driven mechanisms.”
Background
Metadata
- Authors
- du Plessis, T., Djouani, K., & Oosthuizen, C.
- Venue
- Robotics
- Publisher
- MDPI AG
- Published
- 2021-03-03
- Volume
- 10
- Issue
- 1
- Pages
- 40
- ISSN
- 2218-6581 (ISSN-L)
- OpenAlex
- W3133584254
- Cited by
- 218
- References
- 61
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Active Hand Exoskeletons for Rehabilitation and Assistance. https://app.cochat.ai/papers/10.3390/robotics10010040
- The paper
- du Plessis, T., Djouani, K., & Oosthuizen, C. (2021). A Review of Active Hand Exoskeletons for Rehabilitation and Assistance. Robotics. https://doi.org/10.3390/robotics10010040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.