Additively manufactured metallic biomaterials
Open accessThe DOI matches its Crossref record; 243 of the 243 references it cites were found in a registry or an index.
Abstract
Metal additive manufacturing (AM) has led to an evolution in the design and fabrication of hard tissue substitutes, enabling personalized implants to address each patient's specific needs. In addition, internal pore architectures integrated within additively manufactured scaffolds, have provided an opportunity to further develop and engineer functional implants for better tissue integration, and long-term durability. In this review, the latest advances in different aspects of the design and manufacturing of additively manufactured metallic biomaterials are highlighted. After introducing metal AM processes, biocompatible metals adapted for integration with AM machines are presented. Then, we elaborate on the tools and approaches undertaken for the design of porous scaffold with engineered internal architecture including, topology optimization techniques, as well as unit cell patterns based on lattice networks, and triply periodic minimal surface. Here, the new possibilities brought by the functionally gradient porous structures to meet the conflicting scaffold design requirements are thoroughly discussed. Subsequently, the design constraints and physical characteristics of the additively manufactured constructs are reviewed in terms of input parameters such as design features and AM processing parameters. We assess the proposed applications of additively manufactured implants for regeneration of different tissue types and the efforts made towards their clinical translation. Finally, we conclude the review with the emerging directions and perspectives for further development of AM in the medical industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Additive manufacturing of metals
Herzog, D., Seyda, V., Wycisk, E., & Emmelmann, C. (2016) · Acta Materialia · doi:10.1016/j.actamat.2016.07.019 · Cited by 4,759 · cited 3×
“217 compared to LPBF is the high build rate and volumes [32].”
BackgroundInfluentialGibson, I., Rosen, D., & Stucker, B. (2015) · doi:10.1007/978-1-4939-2113-3 · Cited by 3,299
Additive Manufacturing Technologies: Rapid Prototyping to Direct Digital Manufacturing
Gibson, I., Rosen, D. W., & Stucker, B. (2010) · National University of Singapore · doi:10.1007/978-1-4419-1120-9 · Cited by 2,969
A study of the microstructural evolution during selective laser melting of Ti–6Al–4V
Thijs, L., Verhaeghe, F., Craeghs, T., Humbeeck, J. V., & Kruth, J.-P. (2010) · Acta Materialia · doi:10.1016/j.actamat.2010.02.004 · Cited by 2,929 · cited 1×
“From a metallurgical standpoint, the microstructure of the as-built LPBF processed Ti–6Al–4V alloys is acicular martensitic or α′ phase structure with high dislocation density because of the high cooling rates [76].”
BackgroundTopology optimization approaches: A comparative review
Sigmund, O., & Maute, K. (2013) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-013-0978-6 · Cited by 2,890 · cited 1×
“Topology optimization aims at obtaining the optimal structural layout of a design for a set of objectives under certain constraints [132].”
BackgroundMaterials Properties Handbook: Titanium Alloys
Boyer, R. R., Welsch, G. E., & Collings, E. W. (1994) · Medical Entomology and Zoology · Cited by 2,637
The COC algorithm, Part II: Topological, geometrical and generalized shape optimization
Zhou, M., & Rozvany, G. I. N. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90046-9 · Cited by 1,827
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Recent metallic materials for biomedical applications
Niinomi, M. (2002) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-002-0109-2 · Cited by 1,508 · cited 2×
“This problem is addressed by introducing an ASTM F799 alloy that is a Ni-free Co–28Cr–6Mo wrought alloy [85].”
BackgroundMethodCarroll, B. E., Palmer, T. A., & Beese, A. M. (2015) · Acta Materialia · doi:10.1016/j.actamat.2014.12.054 · Cited by 1,507 · cited 2×
“The layer thickness is normally in the range of 40 μm to 1 mm [35,36].”
Background
Cited by
Ahmed, G. H. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.105863 · Cited by 224
Metadata
- Authors
- Davoodi, E., Montazerian, H., Mirhakimi, A. S., Zhianmanesh, M., Ibhadode, O., Shahabad, S. I., Esmaeilizadeh, R., Sarikhani, E., Toorandaz, S., Sarabi, S. A., Nasiri, R., Zhu, Y., Kadkhodapour, J., Li, B., Khademhosseini, A., & Toyserkani, E.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2022-09
- Volume
- 15
- Pages
- 214-249
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W4200078716
- Cited by
- 224
- References
- 243
- FWCI
- 14.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.