Mg and its alloys evince strong candidature for biodegradable bone implants, cardiovascular stents, and wound closing devices. However, their rapid degradation rate causes premature implant failure, constraining clinical applications. Bio-functional surface coatings have emerged as the most competent strategy to fulfill the diverse clinical requirements, besides yielding effective corrosion resistance. This article reviews the progress of biodegradable and advanced surface coatings on Mg alloys investigated in recent years, aiming to build up a comprehensive knowledge framework of coating techniques, processing parameters, performance measures in terms of corrosion resistance, adhesion strength, and biocompatibility. Recently developed conversion and deposition type surface coatings are thoroughly discussed by reporting their essential therapeutic responses like osteogenesis, angiogenesis, cytocompatibility, hemocompatibility, anti-bacterial, and controlled drug release towards in-vitro and in-vivo study models. The challenges associated with metallic, ceramic and polymeric coatings along with merits and demerits of various coatings have been illustrated. The use of multilayered hybrid coating comprising a unique combination of organic and inorganic components has been emphasized with future perspectives to obtain diverse bio-functionalities in a facile single coating system for orthopedic implant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–250 of 250
Li, T., Xu, W., Liu, C., He, J., Wang, Q., Zhang, D., Sui, K.-D., Zhang, Z., Sun, H., Yang, K., et al. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00288 · Cited by 41 · cited 1×
“Additionally, the formation of highly alkalized micro-environment at the tissue/implant interface cause cell-apoptosis [15].”
BackgroundKannan, M. B., & Liyanaarachchi, S. (2013) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2013.07.028 · Cited by 40
Europium-Doped Cerium Oxide Nanoparticles for Microglial Amyloid Beta Clearance and Homeostasis
Machhi, J., Yeapuri, P., Marković, M., Patel, M., Yan, W., Lu, Y., Cohen, J. D., Hasan, M., Abdelmoaty, M. M., Zhou, Y., et al. (2022) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.1c00847 · Cited by 40 · cited 1×
“for suppression of oxidative stress and free radical production, which otherwise, could promote several neurodegenerative diseases, such as Parkinson’s disease, trauma, ischemic stroke, Alzheimer’s disease (AD), and aging [96].”
BackgroundBakhsheshi‐Rad, H. R., HAMZAH, E. B., Ying, W. S., Razzaghi, M., Sharif, S., Ismail, A. F., & Berto, F. (2021) · Materials · doi:10.3390/ma14081930 · Cited by 38 · cited 1×
“[367] dip coated a noble PCL/Chitosan composite coating on Mg.”
Effect of Microstructure on Corrosion Behavior of Mg–Sr Alloy in Hank’s Solution
Dong, J., Tan, L., Ren, Y., & Yang, K. (2018) · Acta Metallurgica Sinica (English Letters) · doi:10.1007/s40195-018-0750-4 · Cited by 38 · cited 2×
“Some of the Mg alloys such as Mg-Zn-Ca [28], Mg-Ca-La [29], Mg-Sr [30], Mg-Mn-Ca-Zn [31] demonstrated bio-safe degradation rates in the range of 0.2–0.5 mm/year in physiological media due to their tendency to form noble composite oxide layers which act as effective shields against aggressive ions of physiological medi…”
BackgroundInfluentialHan, L., Zhang, Z., Dai, J., Li, X., Bai, J., Huang, Z., Guo, C., Xue, F., & Chu, C. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.05.049 · Cited by 38 · cited 1×
“However, considerable residual stress value (~200 MPa) in the coatings result in fatigue cracking and loss in adhesion strength under dynamic loading conditions [84].”
BackgroundBose, S., Li, S., Mele, E., & Silberschmidt, V. V. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103983 · Cited by 38
Improved cytocompatibility of Mg-1Ca alloy modified by Zn ion implantation and deposition
Liu, J., Zheng, Y., Bi, Y., Li, Y., & Zheng, Y. (2017) · Materials Letters · doi:10.1016/j.matlet.2017.06.055 · Cited by 37
Saranya, K., Kalaiyarasan, M., Chatterjee, S., & Rajendran, N. (2019) · Materials and Corrosion · doi:10.1002/maco.201810360 · Cited by 37
Biodegradable magnesium alloy coated by fluoridated hydroxyapatite using MAO/EPD technique
Razavi, M., Fathi, M., Savabi, O., Vashaee, D., & Tayebi, L. (2014) · Surface Engineering · doi:10.1179/1743294414y.0000000284 · Cited by 37 · cited 4×
“P coatings including HA [160–163] and FHA [164,165] by combination of MAO and EPD techniques.”
InfluentialSharma, G. K., Kumar, K., Satsangi, P. S., & Sharma, N. (2021) · IRBM · doi:10.1016/j.irbm.2021.02.003 · Cited by 36
Self-citationPeng, F., Cheng, S., Zhang, R., Li, M., Zhou, J., Wang, D., & Zhang, Y. (2021) · Regenerative Biomaterials · doi:10.1093/rb/rbaa044 · Cited by 35
Recent progress of self-healing coatings for magnesium alloys protection
Johari, N. A. S., Alias, J., Zanurin, A., Mohamed, N. S., Alang, N. A., & Zain, M. Z. M. (2022) · Journal of Coatings Technology and Research · doi:10.1007/s11998-021-00599-2 · Cited by 35 · cited 1×
“MnO4 , La3+, Pr3+, VO3 ), PO4 demonstrate the best suitability for biomedical self-healing coatings [375].”
BackgroundLiu, Y., Bian, D., Wu, Y., Li, N., Qiu, K., Zheng, Y., & Han, Y. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.05.050 · Cited by 35
Kaczmarek, B., Wekwejt, M., Nadolna, K., Owczarek, A., Mazur, O., & Pałubicka, A. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103916 · Cited by 34
Zhang, M., Cai, S., Zhang, F., Xu, G., Wang, F.-W., Yu, N., & Wu, X. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5876-9 · Cited by 34 · cited 1×
“Several attempts have been made to address the issue by pre-treatment and compounding with other elements, but it further alleviates the problem [116].”
BackgroundAttarzadeh, N., Kazemi, A., Molaei, M., & Fattah‐alhosseini, A. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.160275 · Cited by 34
Corrosion resistance and degradation behavior of anodized Mg-Gd alloys: A comparative study
Geng, Z., Li, X., Zhang, Y., Lin, E., Kure‐Chu, S., Li, X., & Xiao, X. (2021) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2021.127042 · Cited by 33 · cited 1×
“[173] the composition of Mg alloys effects the corrosion resistance offered by oxide layers.”
BackgroundWeng, W., Wu, W., Yu, X., et al. (2020) · Materials · doi:10.3390/ma13173834 · Cited by 31 · cited 1×
“Due to its pore sealing tendency, ALD is widely employed in composite form with other coating architectures [251,252].”
BackgroundAnticancer Activity of Samarium-Coated Magnesium Implants for Immunocompromised Patients
Saranya, K., & Rajendran, N. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00400 · Cited by 30 · cited 1×
“[93] reported anti-cancer activity of electrophoretically obtained samarium (Sm) conversion coating on AZ31 Mg alloy.”
BackgroundDong, Y., Wang, T., Xu, Y., Guo, Y., Li, G., & Lian, J. (2022) · Materialia · doi:10.1016/j.mtla.2022.101315 · Cited by 29 · cited 1×
“[369] developed a PDA/Ca–P/GO composite coating to stimulate cell growth and adhesion for improved”
BackgroundLiang, T., Zeng, L., Shi, Y., Pan, H., Chu, P. K.-H., Yeung, K., & Zhao, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.02.025 · Cited by 29 · cited 1×
“The primary advantages like selective surface modification, low temperature, and reproducibility are significant for coating Mg alloys [180,181].”
BackgroundOuyang, J., Hong, X., & Gao, Y. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126562 · Cited by 28
Zeng, R., Liu, L., Luo, K., Shen, L., Zhang, F., Li, S., & Yu-hong, Z. O. U. (2015) · Transactions of Nonferrous Metals Society of China · doi:10.1016/s1003-6326(15)64052-3 · Cited by 27
Dual function of poly(acrylic acid) on controlling amorphous mediated hydroxyapatite crystallization
Jiang, S., Cao, Y., Li, S., Pang, Y., & Sun, Z. (2020) · Journal of Crystal Growth · doi:10.1016/j.jcrysgro.2020.125991 · Cited by 27 · cited 1×
“Additionally, they acted as heterogeneous nucleation sites where Mg2+ and Ca2+ combined with PO4 ions [133].”
BackgroundDu, M., Peng, M., Mai, B., Hu, F., Zhang, X., Chen, Y., & Wang, C. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.125336 · Cited by 27
Titanium dioxide coatings on magnesium alloys for biomaterials: A review
Hernández-Montes, V., Henao, C. P. B., & Santa, J. F. (2017) · DYNA · doi:10.15446/dyna.v84n200.59664 · Cited by 27 · cited 1×
“In the second phase, the polycondensation responsible for the 3-d oxide network is achieved by either dip, spin, immersion, or spray coating methods [289,290].”
Ion Implantation of Calcium and Zinc in Magnesium for Biodegradable Implant Applications
Somasundaram, S., Ionescu, M., & Mathan, B. (2018) · Metals · doi:10.3390/met8010030 · Cited by 26 · cited 1×
“However, amorphization caused during ion implantation causes surface devoid of grain boundaries, resulting in enhanced corrosion [182].”
BackgroundTang, X., Zhang, X., Chen, Y., Zhang, W., Qian, J., Soliman, H., Ai, Q., Liu, Q., Pu, S., Huang, N., et al. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110487 · Cited by 25
Guo, J., Liu, X., Du, K., Guo, Q., Wang, Y., Liu, Y., & Feng, L. M. (2019) · Materials Letters · doi:10.1016/j.matlet.2019.126912 · Cited by 24
Šupová, M. (2020) · Materials · doi:10.3390/ma13020327 · Cited by 24 · cited 8×
“A noble two-step spin-spray deposition process was utilized by Zhao et al. [353] for layer-by-layer deposition of polyacrylic acid (PAA) N. Singh et al. Bioactive Materials 19 (2023) 717–757 746 modified CeO2 nanoparticles and 3-aminopropyl trimethoxysilane (3-APTMS) modified SiO2 nanoparticles on AZ31 magnesium alloy.”
BackgroundInfluentialQiu, Z.-M., Zhang, F., Chu, J.-T., Li, Y., & Song, L. (2020) · Frontiers of Materials Science · doi:10.1007/s11706-020-0492-x · Cited by 24
Yang, S., Chen, Z., Chen, T., & Fu, C. (2020) · ACS Applied Nano Materials · doi:10.1021/acsanm.0c00616 · Cited by 23
Treatment options for aseptic tibial diaphyseal nonunion: A review of selected studies
Gálvez-Sirvent, E., Ibarzábal-Gil, A., & Rodriguez-Merchan, E. C. (2020) · EFORT Open Reviews · doi:10.1302/2058-5241.5.190077 · Cited by 23
Zhang, H., Shen, X., Wang, J., Huang, N., Luo, R., Zhang, B., & Wang, Y. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.9b01459 · Cited by 22
Helmholz, H., Will, O., Peñate-Medina, T., Humbert, J., Damm, T., Luthringer-Feyerabend, B., Willumeit‐Römer, R., Glüer, C., & Medina, O. P. (2021) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37148 · Cited by 22
Erişen, D. E., Zhang, Y., Zhang, B., Yang, K., Chen, S., & Wang, X. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34907 · Cited by 22 · cited 1×
“Secondly, Mg suffers from an abnormal phenomenon of negative difference effect (NDE) where corrosion rate and hydrogen evolution increase rapidly with an increase in corrosion potential, which may lead to blockage of blood paths and cause tissue necrosis by H2 accumulation [14].”
BackgroundHe, X., Zhang, G., Pei, Y., & Zhang, H. (2020) · Journal of Biomaterials Applications · doi:10.1177/0885328219899233 · Cited by 21
Sun, X. J., Yao, Q.-S., Li, Y., et al. (2020) · Frontiers of Materials Science · doi:10.1007/s11706-020-0522-8 · Cited by 16
Chen, M., Wang, M., Li, B., Winston, D. D., Cheng, W., Han, Y. N., & Lei, B. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129198 · Cited by 16
Vasanthavel, S., Kumar, M., & Kannan, S. (2020) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2020.157185 · Cited by 15
Zomorodian, A., Ribeiro, I., Fernandes, J. C. S., Matos, A. C., Santos, C. F., Bettencourt, A., & Montemor, M. F. (2017) · International Journal of Polymeric Materials · doi:10.1080/00914037.2016.1252347 · Cited by 12
Kannan, M. B., Walter, R., Khakbaz, H., Zeng, R., & Blawert, C. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10070 · Cited by 11 · cited 1×
“[152] fabricated an inorganic Ca–P layer sandwiched between the MAOed and PLLA layers on pure Mg substrate using a spin coating technique.”
MethodLi, S., Yi, L., Liu, T., Deng, H., Ji, B. H., Zhang, K., & Zhou, L. (2020) · Materials and Corrosion · doi:10.1002/maco.201911488 · Cited by 10
Biosynthesis of Bonelike Apatite 2D Nanoplate Structures Using Fenugreek Seed Extract
Abdal‐hay, A., Fouad, H., Alshammari, B. A., & Khalil, K. A. (2020) · Nanomaterials · doi:10.3390/nano10050919 · Cited by 10
Lee, J. H., Baek, S. M., Lee, G., Kim, S., Kim, H. S., & Hahn, S. K. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01179 · Cited by 10 · cited 1×
“Despite efficient corrosion inhibition, a few generic limitations like high susceptibility towards hydrolysis, entrapment of H2 during in-vitro immersion, and poor adhesion towards Mg substrate hampers its usage for orthopedic implant application [300].”
BackgroundWu, X., Liu, Z., Liu, X., Xie, H., Liu, F., Lu, C. J., & Li, J. (2020) · Materials and Corrosion · doi:10.1002/maco.202012166 · Cited by 7 · cited 1×
“ride media over large pH fluctuations, usually occurring during Mg corrosion [89].”
BackgroundPolymer-induced liquid precursors (PILPs) and bone regeneration
Sugawara‐Narutaki, A., Nakamura, J., & Ohtsuki, C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102999-2.00017-x · Cited by 5 · cited 1×
“Several organic compounds like dopamine, EDTA, arginine-glycine-aspartic acid-cysteine (RGDC) peptides are widely recognized for their unique molecular recognition feature, which accelerated HA formation on implant surface [270].”
BackgroundYang, K. H., Hu, B., An, S.-N., Chen, W.-T., Cui, L., & Li, S. (2021) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-021-06130-3 · Cited by 5 · cited 1×
“[135] developed a defect-free SiO2/PAA coating that acts as a template for mineralizing Ca–P layers on AZ31 Mg alloy.”
BackgroundTechniques for Thin Films of Advanced Materials
Sinju, K. R., Debnath, A. K., & Ramgir, N. S. (2022) · Indian Institute of Metals series · doi:10.1007/978-981-16-1803-1_3 · Cited by 4 · cited 1×
“Magnetron sputtering is preferred over e-beam as it is directional, covers fewer steps, and forms shadow effect [232].”
Background
Cited by
Advances in orthodontic clear aligner materials
Bichu, Y. M., Alwafi, A., Liu, X., Andrews, J., Ludwig, B., Bichu, A. Y., & Zou, B. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.10.006 · Cited by 274
Zhao, Y., He, P., Wang, B., Bai, J., Xue, F., & Chu, C. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.12.004 · Cited by 60
Qi, G., Ma, T., Wang, Y., Chen, K., Yan, Y., Li, Z., Deng, N., Tseng, C., Li, B., Zheng, Y., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-72683-3 · Cited by 2
Metadata
- Authors
- Singh, N., Batra, U., Kumar, K., Ahuja, N., & Mahapatro, A.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2023-01
- Volume
- 19
- Pages
- 717-757
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W4280611586
- Cited by
- 165
- References
- 250
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.