Progress in bioactive surface coatings on biodegradable Mg alloys: A critical review towards clinical translation
Open accessThe DOI matches its Crossref record; 250 of the 250 references it cites were found in a registry or an index.
Abstract
Mg and its alloys evince strong candidature for biodegradable bone implants, cardiovascular stents, and wound closing devices. However, their rapid degradation rate causes premature implant failure, constraining clinical applications. Bio-functional surface coatings have emerged as the most competent strategy to fulfill the diverse clinical requirements, besides yielding effective corrosion resistance. This article reviews the progress of biodegradable and advanced surface coatings on Mg alloys investigated in recent years, aiming to build up a comprehensive knowledge framework of coating techniques, processing parameters, performance measures in terms of corrosion resistance, adhesion strength, and biocompatibility. Recently developed conversion and deposition type surface coatings are thoroughly discussed by reporting their essential therapeutic responses like osteogenesis, angiogenesis, cytocompatibility, hemocompatibility, anti-bacterial, and controlled drug release towards in-vitro and in-vivo study models. The challenges associated with metallic, ceramic and polymeric coatings along with merits and demerits of various coatings have been illustrated. The use of multilayered hybrid coating comprising a unique combination of organic and inorganic components has been emphasized with future perspectives to obtain diverse bio-functionalities in a facile single coating system for orthopedic implant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436 · cited 1×
“The primary issue about Mg-based implants is rapid degradation in a complex physiological environment, which deteriorates mechanical integrity and causes implant failure (within 4–6 weeks), even before the complete healing of natural bone, which usually takes 8–12 weeks [11].”
BackgroundA review on fundamentals and applications of electrophoretic deposition (EPD)
BESRA, L., & LIU, M. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2006.07.001 · Cited by 2,258 · cited 2×
“The coating morphology is influenced by the suspension parameters like particle size, liquid dielectric constant, conductivity, viscosity, and Zeta protentional of medium [260].”
BackgroundBiomedical coatings on magnesium alloys – A review
Hornberger, H., Virtanen, S., & Boccaccini, A. R. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.012 · Cited by 1,273 · cited 1×
“Majorly reported chemical conversion coatings on Mg alloys are based on chromates, fluorides, phosphates, and rare earth (RE) elements [67].”
BackgroundAgarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
Sankara Narayanan, T. S. N., Park, I. S., & Lee, M. H. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.08.002 · Cited by 639
Measurements of the mechanical response of unidirectional 3D-printed PLA
Song, Y., Li, Y., Song, W., Yee, K., Lee, K.-Y., & Tagarielli, V. L. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.03.051 · Cited by 624 · cited 1×
“It is extensively explored for surgical devices, tissue engineering, bone fixation, and drug delivery applications due to its biocompatibility, hydrophobicity, and thermoplastic processability [292].”
BackgroundBiodegradable Mg alloys for orthopedic implants – A review
Tsakiris, V., Tardei, C., & Clicinschi, F. M. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.06.024 · Cited by 612 · cited 1×
“Under chronic exposure, significant loss of dendrite and soma of neurons induced down-expressions and other behavioural deficits [6,100].”
BackgroundOn Coating Techniques for Surface Protection: A Review
Fotovvati, B., Namdari, N., & Dehghanghadikolaei, A. (2019) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp3010028 · Cited by 609 · cited 1×
“In the second phase, the polycondensation responsible for the 3-d oxide network is achieved by either dip, spin, immersion, or spray coating methods [289,290].”
Zhao, Y., Li, Z., Song, S., Yang, K., Liu, H., Yang, Z., Wang, J., Yang, B., & Lin, Q. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201901474 · Cited by 528
Hierarchical Structures of Bone and Bioinspired Bone Tissue Engineering
Liu, Y., Luo, D., & Wang, T. (2016) · Small · doi:10.1002/smll.201600626 · Cited by 482 · cited 2×
“The mineralized HA must have its c-axis [001] parallel to longitudinal fibrils of cortical bone to deeply penetrate inside collagen fibrils for better adhesion [269].”
BackgroundAdvances in functionalized polymer coatings on biodegradable magnesium alloys–A review
Li, L.-Y., Cui, L.-Y., Zeng, R.-C., Li, S.-Q., Chen, X.-B., Zheng, Y., & Kannan, M. B. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.030 · Cited by 466 · cited 2×
“The physical, chemical, and mechanical properties of PLGA can be tailored by altering LA/GA ratio [297].”
BackgroundMg bone implant: Features, developments and perspectives
Yang, Y., He, C., Dianyu, E., Yang, W., Qi, F., Xie, D., Shen, L., Peng, S., & Shuai, C. (2020) · Materials & Design · doi:10.1016/j.matdes.2019.108259 · Cited by 433
Li, X., Liu, X., Wu, S., Yeung, K. W. K., Zheng, Y., & Chu, P. K. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.005 · Cited by 428 · cited 1×
“Moreover, alloying of Mg is always challenging due to the low solubility and non-uniform distribution of most alloying elements, resulting in heterogenous and coarse secondary phases [36].”
BackgroundAdvances in coatings on biodegradable magnesium alloys
Yin, Z.-Z., Qi, W.-C., Zeng, R.-C., Chen, X.-B., Gu, C.-D., Guan, S.-K., & Zheng, Y.-F. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2019.09.008 · Cited by 419 · cited 1×
“niques like friction stir processing (FSP), shot peening (SP), and surface mechanical attrition treatment (SMAT) employ mechanical working to physically alter the surface properties of Mg alloys by grain refinement [42,43].”
MethodAdvances in synthesis of calcium phosphate crystals with controlled size and shape
Lin, K., Wu, C., & Chang, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.017 · Cited by 414 · cited 1×
“Nano-plate and nano-sphere like structures greatly enhance the cell attachment compared to whisker or flake-like HA crystal structures [74].”
BackgroundMagnesium matrix composites for biomedical applications: A review
Bommala, V. K., Krishna, M. G., & Rao, C. T. (2019) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2018.11.001 · Cited by 393 · cited 1×
“Nowadays, various ceramic reinforcements including β-TCP [33], HA [34], and calcium polyphosphate (CPP) [35] have also been reported to enhance corrosion resistance, bioactivity and mechanical strength of Mg alloys.”
BackgroundHierarchical layered double hydroxide nanocomposites: structure, synthesis and applications
Gu, Z., Atherton, J. J., & Xu, Z. P. (2015) · Chemical Communications · doi:10.1039/c4cc07715f · Cited by 389
Shape-selective zeolite catalysis for bioplastics production
Dusselier, M., Van Wouwe, P., Dewaele, A., Jacobs, P. A., & Sels, B. F. (2015) · Science · doi:10.1126/science.aaa7169 · Cited by 376 · cited 1×
“[295] proposed manipulating the physical properties and hydrolytic degradation of PLA by the racemization of D - and L -isomers or utilizing a hydroxyl acid co-monomer component but still thorough investigation is needed to tailor the physicochemical properties of PLA for long-term implant applications.”
BackgroundPEG–PLGA copolymers: Their structure and structure-influenced drug delivery applications
Zhang, K., Tang, X., Zhang, J., Lu, W., Lin, X., Zhang, Y., Tian, B., Yang, H., & He, H. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.026 · Cited by 374 · cited 1×
“PLGA coatings are widely recognized for corrosion resistance and drug delivery applications [298,299].”
BackgroundAvcu, E., Baştan, F. E., Abdullah, H. Z., Rehman, M. A. U., Avcu, Y. Y., & Boccaccini, A. R. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.01.001 · Cited by 358
Shen, X., Zhang, Y., Ma, P., Sutrisno, L., Luo, Z., Hu, Y., Yu, Y., Tao, B., Li, C., & Cai, K. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.05.008 · Cited by 291
Micro‐arc oxidation of magnesium alloys: A review
Yao, W., Wu, L., Wang, J., Jiang, B., Zhang, D., Serdechnova, M., Shulha, T., Blawert, C., Zheludkevich, M. L., & Pan, F. (2022) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.11.053 · Cited by 287 · cited 1×
“These coatings are characterized by their highly uniform crystalline structure, improved bonding strength, wear resistance, reproducibility, and facile thickness control [41].”
BackgroundLayered double hydroxide (LDH) for multi-functionalized corrosion protection of metals: A review
Cao, Y., Zheng, D., Zhang, F., Pan, J., & Lin, C. (2022) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2021.05.078 · Cited by 279 · cited 1×
“The release of Mg2+ and Al3+ ions from the substrate during dissolution provides a necessary supply of cations for the formation of the cationic layer [207].”
BackgroundLayered double hydroxide coatings on magnesium alloys: A review
Guo, L., Wu, W., Zhou, Y., Zhang, F., Zeng, R., & Zeng, J. (2018) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2018.03.003 · Cited by 262
Magnesium degradation under physiological conditions – Best practice
Gonzalez, J., Hou, R. Q., Nidadavolu, E. P. S., Willumeit-Römer, R., & Feyerabend, F. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.01.003 · Cited by 262
Preparation and solubility of hydroxyapatite
Moreno, E. C., Gregory, T. M., & Brown, W. E. (1968) · Journal of Research of the National Bureau of Standards Section A Physics and Chemistry · doi:10.6028/jres.072a.052 · Cited by 253 · cited 1×
“7 × 10 58) is considered the most stable form of apatite [86].”
BackgroundLiu, Q., Ma, Q.-X., Chen, G.-Q., Cao, X., Zhang, S., Pan, J.-L., Zhang, G., & Shi, Q.-Y. (2018) · Corrosion Science · doi:10.1016/j.corsci.2018.04.028 · Cited by 243
Magnesium incorporated hydroxyapatite: Synthesis and structural properties characterization
Farzadi, A., Bakhshi, F., Solati-Hashjin, M., Asadi-Eydivand, M., & Osman, N. A. A. (2014) · Ceramics International · doi:10.1016/j.ceramint.2013.11.051 · Cited by 243 · cited 1×
“Such a substitution creates structural disorder in HA lattice, which results in high solubility and poor crystallinity with prolonged immersion in physiological media [87].”
BackgroundRecent advances in biodegradation controls over Mg alloys for bone fracture management: A review
Song, M.-S., Zeng, R.-C., Ding, Y.-F., Li, R. W., Easton, M., Cole, I., Birbilis, N., & Chen, X.-B. (2019) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2018.10.008 · Cited by 230 · cited 2×
“In contrast, some studies utilized it as a post-treatment technique to convert amorphous dicalcium phosphate dehydrate (DCPD) coatings to highly crystalline HA coatings, which efficiently shielded the Mg substrate in physiological media [3,141,201, 202].”
BackgroundResultAnjum, M. J., Zhao, J., Asl, V. Z., Yasin, G., Wang, W., Wei, S., Zhao, Z., & Khan, W. Q. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.05.022 · Cited by 228
Duan, G., Yang, L., Liao, S., Zhang, C., Lu, X., Yang, Y., Zhang, B., Wei, Y., Zhang, T., Yu, B., et al. (2018) · Corrosion Science · doi:10.1016/j.corsci.2018.02.051 · Cited by 217 · cited 1×
“Once bath media reaches the surface of Mg substrate, conversion phenomena again initiated, which facilitates the enrichment of coating density [65].”
BackgroundWang, R., & Guo, S. (2021) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12714 · Cited by 216
The current trends of Mg alloys in biomedical applications—A review
Riaz, U., Shabib, I., & Haider, W. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34290 · Cited by 213 · cited 1×
“Micro-alloying considered as a promising method to tailor the degradation rate [25,26] by alloying the Mg with relatively noble elements like Calcium (Ca), Zinc (Zn), Aluminium (Al), Manganese (Mn), Lithium (Li), Scandium (Sc), Strontium (Sr), and rare earth (RE) elements [27].”
BackgroundPolydopamine-based nanomaterials and their potentials in advanced drug delivery and therapy
Li, H., Yin, D., Li, W., Tang, Q., Zou, L., & Peng, Q. (2021) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2020.111502 · Cited by 198 · cited 1×
“Additional application features biosensing and target drug delivery make it a suitable candidate for the coating of biodegradable Mg implants [310].”
BackgroundRole of protein adsorption in the bio corrosion of metallic implants – A review
Talha, M., Ma, Y., Kumar, P., Lin, Y., & Singh, A. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2019.01.038 · Cited by 192 · cited 1×
“Nevertheless, it is still debatable to determine whether the proteins assist or hinder the corrosion phenomena of Mg alloys [18].”
BackgroundSurface treatments for controlling corrosion rate of biodegradable Mg and Mg-based alloy implants
Uddin, M. S., Hall, C., & Murphy, P. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/5/053501 · Cited by 189 · cited 1×
“substrate) serves as an anode and an oxide film is grown on the Mg substrate in presence of aqueous or non-aqueous electrolyte [167].”
BackgroundQadir, M., Li, Y., & Wen, C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.006 · Cited by 189 · cited 1×
“In magnetron sputtering, a magnetic field is configured parallel to the target surface for constraining the electron motion; thus, highly uniform coatings are yielded [233].”
BackgroundJee, S.-S., Thula, T. T., & Gower, L. B. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.03.036 · Cited by 188
Shang, W., Chen, B., Shi, X., Chen, Y., & Xiao, X. (2009) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2008.06.135 · Cited by 184
Functionalization treatment of micro-arc oxidation coatings on magnesium alloys: a review
Lin, Z., Wang, T., Yu, X., Sun, X., & Yang, H. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.160453 · Cited by 183
Challenges and opportunities for biodegradable magnesium alloy implants
Kumar, K., Gill, R. S., & Batra, U. (2018) · Materials Technology · doi:10.1080/10667857.2017.1377973 · Cited by 182 · cited 1×
“by microstructural and surface modification strategies [24].”
Self-citationProtection of magnesium alloys: From physical barrier coating to smart self-healing coating
Zhang, D., Peng, F., & Liu, X. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2020.157010 · Cited by 182 · cited 2×
“Accordingly, attention has been focused on developing coating systems that complement essential clinically features [51].”
BackgroundSekar, P., Narendranath, S., & Desai, V. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.11.001 · Cited by 176
Munir, K., Lin, J., Wen, C., Wright, P. F. A., & Li, Y. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.001 · Cited by 175
Poly(lactic-co-glycolic acid) microsphere production based on quality by design: a review
Hua, Y., Su, Y., Zhang, H., Liu, N., Wang, Z., Gao, X., Gao, J., & Zheng, A. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1943056 · Cited by 175
HA coating on Mg alloys for biomedical applications: A review
Rahman, M., Li, Y., & Wen, C. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.05.003 · Cited by 174 · cited 1×
“The chemical conversion method can quickly obtain such desired coating morphologies by varying the process parameters like pH, bath temperature, and treatment time, which is difficult to control by other coating techniques [75].”
MethodZheludkevich, M. L., Tedim, J., Freire, C. S. R., Fernandes, S. C. M., Kallip, S., Lisenkov, A. D., Gandini, A., & Ferreira, M. G. S. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10304k · Cited by 172 · cited 1×
“They form insoluble complexes by chelation with metallic ions released from the substrate at damaged site, which imparts self-healing coating characteristics [113].”
BackgroundInterfacial bond strength of electrophoretically deposited hydroxyapatite coatings on metals
Wei, M., Ruys, A. J., Swain, M. V., Kim, H. S., MILTHORPE, B. K., & Sorrell, C. C. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008923029945 · Cited by 168 · cited 12×
“The pinning force generated by RNHA deposition in the MAO pores increased the adhesion strength of HA coating up to 40 MPa.”
BackgroundInfluentialAdvances in microarc oxidation coated AZ31 Mg alloys for biomedical applications
Zhang, L., Zhang, J., Chen, C.-F., & Gu, Y. (2015) · Corrosion Science · doi:10.1016/j.corsci.2014.11.001 · Cited by 164
Chen, X. B., Nisbet, D. R., Li, R. W., Smith, P. N., Abbott, T. B., Easton, M. A., Zhang, D.-H., & Birbilis, N. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.11.016 · Cited by 163
Hybrid Sol-Gel Coatings: Smart and Green Materials for Corrosion Mitigation
Figueira, R. B., Fontinha, I. R., Silva, C. J. R., & Pereira, E. V. (2016) · Coatings · doi:10.3390/coatings6010012 · Cited by 162 · cited 1×
“Sol-gel is the highly reported coating technique for Mg and its alloys due to its capability to coat organic and inorganic materials on Mg alloys [287].”
BackgroundDegradation Behavior of Polymers Used as Coating Materials for Drug Delivery—A Basic Review
Visan, A. I., Popescu-Pelin, G., & Socol, G. (2021) · Polymers · doi:10.3390/polym13081272 · Cited by 161 · cited 1×
“However, polymers are prone to hydrolysis in physiological media, which rapidly increases permeability and facilitates the absorption of aggressive ions [389].”
BackgroundRojaee, R., Fathi, M., & RAEISSI, K. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.05.014 · Cited by 160
Peron, M., Torgersen, J., & Berto, F. (2017) · Metals · doi:10.3390/met7070252 · Cited by 159 · cited 1×
“The coatings for Mg-based implants are expected to facilitate biodegradation at a tailored rate by offering a limited barrier function based upon the bone reunion period [381].”
BackgroundYang, S., Sun, R., & Chen, K. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.131198 · Cited by 156 · cited 1×
“Organic coatings – In recent years, organic coatings have received extensive attention for their superior corrosion resistance and multiple bio-functionalities [131,285,286].”
BackgroundOsteogenesis, angiogenesis and immune response of Mg-Al layered double hydroxide coating on pure Mg
Cheng, S., Zhang, D., Li, M., Liu, X., Zhang, Y., Shi, Q., & Peng, F. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.07.014 · Cited by 156
Protein adsorption on magnesium and its alloys: A review
Höhn, S., Virtanen, S., & Boccaccini, A. R. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.08.173 · Cited by 156 · cited 1×
“Other issues, like difference in in-vivo and in-vitro corrosion resistance, limit the clinical translation of Mg-based implants because the corrosion performance in in-vitro conditions ignores the role of proteins and enzymes present in actual physiological media [16,17].”
BackgroundHybrid fracture fixation systems developed for orthopaedic applications: A general review
Li, T. X., Tang, N., Ngai, T., Wu, C. C., Ruan, Y. C., Huang, L., & Qin, L. (2018) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2018.06.006 · Cited by 154 · cited 1×
“, scratching, debonding) even during the implant fixation process [55].”
BackgroundRen, S., Zhou, Y., Zheng, K., Xu, X., Yang, J., Wang, X., Miao, L., Wei, H., & Xu, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.05.037 · Cited by 147 · cited 1×
“Recently, Ce based compounds are reported for promoting angiogenesis induction [97] and peroxidase mimicking activity [98] for breast cancer cell detection.”
BackgroundBiodegradation behavior of micro-arc oxidation coating on magnesium alloy-from a protein perspective
Zhang, Z., Wang, L., Zeng, M.-Q., Zeng, R., Kannan, M. B., Lin, C., & Zheng, Y. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.03.005 · Cited by 147 · cited 1×
“[156] reported the achievement of self-healing characteristics for pore sealing on MAOed AZ31 alloy by incorporation of bovine serum albumin (BSA) in PBS media.”
BackgroundChen, C., Chen, J., Wu, W. G., Shi, Y., Jin, L., Petrini, L., Shen, L., Yuan, G., Ding, W., Ge, J., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119414 · Cited by 145 · cited 1×
“Other issues, like difference in in-vivo and in-vitro corrosion resistance, limit the clinical translation of Mg-based implants because the corrosion performance in in-vitro conditions ignores the role of proteins and enzymes present in actual physiological media [16,17].”
BackgroundBakhsheshi‐Rad, H. R., HAMZAH, E. B., Ismail, A. F., Aziz, M., Daroonparvar, M., Saebnoori, E., & Chami, A. (2017) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2017.11.027 · Cited by 143
Yao, S., Lin, X., Xu, Y., Chen, Y., Qiu, P., Shao, C., Jin, B., Mu, Z., Sommerdijk, N. A. J. M., & Tang, R. (2019) · Advanced Science · doi:10.1002/advs.201900683 · Cited by 141
Recent progress on coatings of biomedical magnesium alloy
Tong, P., Sheng, Y., Hou, R., Iqbal, M., Chen, L., & Li, J. (2021) · Smart Materials in Medicine · doi:10.1016/j.smaim.2021.12.007 · Cited by 140 · cited 1×
“The surface scratches on implants seem unavoidable during surgery, and the partial damages provide pathways for the intake of the aggressive solution and lead to severe local corrosion and even premature coating failures [374].”
BackgroundPotential bioactive coating system for high-performance absorbable magnesium bone implants
Sarian, M. N., Iqbal, N., Sotoudehbagha, P., Razavi, M., Ahmed, Q. U., Sukotjo, C., & Hermawan, H. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.10.034 · Cited by 137
Zhao, Y., Shi, L., Ji, X., Li, J., Han, Z., Li, S., Zeng, R., Zhang, F., & Wang, Z. (2018) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2018.04.071 · Cited by 131 · cited 2×
“[294] prepared a multilayered polymethyltrimethoxysilane (PMTMS)/Silver nanoparticles (AgNPs)/Polyethyleneimine (PEI) LbL assembled coating on AZ31 Mg alloy by dip-coating method.”
BackgroundMethodHybrid nanocomposite coating by sol–gel method: a review
Amiri, S., & Rahimi, A. (2016) · Iranian Polymer Journal · doi:10.1007/s13726-016-0440-x · Cited by 131
Zhang, R., Zhou, X., Gao, H., Mankoci, S., Liu, Y., Sang, X., Qin, H., Hou, X., Ren, Z., Doll, G. L., et al. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.02.009 · Cited by 128 · cited 1×
“Additionally, the unwanted residual stresses generated after thermal or mechanical working affects the corrosion and mechanical properties of Mg alloys [48].”
BackgroundGao, J., Su, Y., & Qin, Y. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.10.024 · Cited by 127
Alabbasi, A., Liyanaarachchi, S., & Kannan, M. B. (2012) · Thin Solid Films · doi:10.1016/j.tsf.2012.07.090 · Cited by 124 · cited 1×
“Few researchers attempted to counter limitations by increasing the coating thickness, but adhesion became poorer [293,294].”
BackgroundKang, J., Dong, E., Li, D., Dong, S., Zhang, C., & Wang, L. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108608 · Cited by 123 · cited 3×
“For orthopedic implant application, Mg alloys possess similar mechanical characteristics with identical young’s modulus (20–45 GPa) comparable to cortical bone (20–27 GPa) [1].”
BackgroundInfluentialBian, D., Deng, J., Li, N., Chu, X., Liu, Y., Li, W., Cai, H., Xiu, P., Zhang, Y., Guan, Z., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b15498 · Cited by 123
Chen, L., Sheng, Y., Zhou, H., Li, Z., Wang, X., & Li, W. (2018) · Corrosion Science · doi:10.1016/j.corsci.2018.12.005 · Cited by 122 · cited 1×
“[147] developed a double-layered MAO/PLGA coating on Mg–4Zn-0.”
BackgroundJamesh, M.-I., Wu, G., Zhao, Y., McKenzie, D. R., Bilek, M., & Chu, P. K.-H. (2013) · Corrosion Science · doi:10.1016/j.corsci.2013.11.044 · Cited by 122 · cited 1×
“[187] fabricated Zr ions using the PIII method on ZK60 Mg alloy.”
MethodYang, Q., Yuan, W., Liu, X., Zheng, Y., Cui, Z., Yang, X., Pan, H., & Wu, S. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.06.015 · Cited by 120 · cited 1×
“[249] deposited a 40 nm thick atomic layer of ZrO2 Nanofilm on Mg–Sr Alloy.”
BackgroundRazavi, M., Fathi, M., Savabi, O., Vashaee, D., & Tayebi, L. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.11.020 · Cited by 117 · cited 4×
“P coatings including HA [160–163] and FHA [164,165] by combination of MAO and EPD techniques.”
InfluentialChunyan, Z., Liao, S., Yu, B., Lu, X., Chen, X., Zhang, T., & Wang, F. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.01.046 · Cited by 114 · cited 1×
“Additionally, process parameters like concentration, pH, and temperature of bath media play essential roles in coating quality [66].”
BackgroundRezaei, A., & Mohammadi, M. R. (2012) · Materials Science and Engineering C · doi:10.1016/j.msec.2012.09.004 · Cited by 114
Saberi, A., Bakhsheshi‐Rad, H. R., Abazari, S., Ismail, A. F., Sharif, S., Ramakrishna, S., Daroonparvar, M., & Berto, F. (2021) · Coatings · doi:10.3390/coatings11070747 · Cited by 114 · cited 1×
“Additionally, polymeric layers are prone to swelling and subsequent delamination in the presence of physiological media [151].”
BackgroundLi, C., Fan, X.-L., Zeng, R., Cui, L., Li, S., Zhang, F., He, Q., Kannan, M. B., Jiang, H.-W. (., Chen, D., et al. (2019) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2019.01.006 · Cited by 114
Zhang, L., Pei, J., Wang, H., Shi, Y., Niu, J., Yuan, F., Huang, H., Zhang, H., & Yuan, G. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b00209 · Cited by 112
Recent advances in multifunctional hydroxyapatite coating by electrochemical deposition
Li, T., Ling, L., Lin, M., Peng, H., Ren, H., Lou, C., & Lin, J. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-04467-z · Cited by 112 · cited 1×
“and slight limitation on substrate shape compared to the ELD process [254,255].”
BackgroundChen, Y., Zhao, S., Chen, M., Zhang, W., Mao, J., Zhao, Y., Maitz, M. F., Huang, N., & Wan, G. (2015) · Corrosion Science · doi:10.1016/j.corsci.2015.03.020 · Cited by 111
A pH-sensitive self-healing coating for biodegradable magnesium implants
Xiong, P., Yan, J., Wang, P. J., Jia, Z., Zhou, W., Yuan, W., Li, Y., Liu, Y., Cheng, Y., Chen, D., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.045 · Cited by 109 · cited 1×
“[322] prepared a self-healing coating comprising; Silk as host and K3PO4 as inhibition agent on Mg–1Ca alloy.”
MethodOsteogenic and pH stimuli-responsive self-healing coating on biomedical Mg-1Ca alloy
Xiong, P., Jia, Z., Zhou, W., Yan, J., Wang, P. J., Yuan, W., Li, Y., Cheng, Y., Guan, Z., & Zheng, Y. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.027 · Cited by 109 · cited 1×
“When stimulated conditions damage the host in corrosive media, the guest is leaked to form a passive layer at the defect site, inhibiting the corrosion propagation [362].”
BackgroundRecent advances in chitosan-based layer-by-layer biomaterials and their biomedical applications
Hu, B., Guo, Y., Li, H., Liu, X., Fu, Y., & Ding, F. (2021) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2021.118427 · Cited by 108
Lei, L., Shi, J. Z., Wang, X., Liu, D., & Haigang, X. (2016) · Applied Surface Science · doi:10.1016/j.apsusc.2016.03.150 · Cited by 107
Lin, B., Zhong, M., Zheng, C., Cao, L., Wang, D., Wang, L., Liang, J., & Cao, B. (2015) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2015.09.033 · Cited by 106
Huang, S., Wang, B., Zhang, X., Lu, F., Wang, Z., Tian, S., Li, D., Yang, J., Cao, F., Cheng, L., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119829 · Cited by 106 · cited 1×
“After providing necessary mechanical fixation upto bone healing time, the implant should be degraded completely and replaced by new bone tissue, eliminating unnecessary follow-up and secondary surgery [5].”
BackgroundJia, Z., Xiong, P., Shi, Y., Zhou, W., Cheng, Y., Zheng, Y., Xi, T., & Wei, S. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb00117c · Cited by 104
Advances in LDH coatings on Mg alloys for biomedical applications: A corrosion perspective
Tan, J. K. E., Balan, P., & Birbilis, N. (2020) · Applied Clay Science · doi:10.1016/j.clay.2020.105948 · Cited by 104 · cited 2×
“However, Al, considered to be neurotoxic, may impede bone calcification and result in osteomalacia when present in excessive levels [210].”
BackgroundOrganic conversion coatings for magnesium and its alloys
Saji, V. S. (2019) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2019.03.018 · Cited by 104 · cited 4×
“[112] investigated that the presence of β-phases in Mg alloys affects the reaction kinetics of conversion phenomena by galvanic coupling, resulting in non-uniform coating thickness.”
BackgroundMethodInfluentialJi, X., Gao, L., Liu, J., Wang, J., Cheng, Q., Li, J., Li, S., Zhi, K.-Q., Zeng, R., & Wang, Z. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.04.029 · Cited by 103
Zai, W., Su, Y., Man, H. C., Lian, J., & Li, G. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.05.309 · Cited by 102 · cited 2×
“The process is triggered by a decrease of the pH and an increase of the Mg2+ concentration at the metal/solution interface [62].”
BackgroundPolymer coatings on magnesium‐based implants for orthopedic applications
Zhu, Y., Liu, W., & Ngai, T. (2021) · Journal of Polymer Science · doi:10.1002/pol.20210578 · Cited by 101 · cited 1×
“PLGA coatings are widely recognized for corrosion resistance and drug delivery applications [298,299].”
BackgroundIn vitro degradation of pure magnesium―the synergetic influences of glucose and albumin
Yan, W., Lian, Y.-J., Zhang, Z., Zeng, M.-Q., Zhang, Z., Yin, Z.-Z., Cui, L., & Zeng, R. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.02.015 · Cited by 100
Bakhsheshi‐Rad, H. R., HAMZAH, E. B., Kasiri-Asgarani, M., Jabbarzare, S., Iqbal, N., & Kadir, M. R. A. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.11.057 · Cited by 99
Selective enzymatic degradation of poly(ε-caprolactone) containing multiblock copolymers
Kulkarni, A., Reiche, J., Hartmann, J., Kratz, K. L., & Lendlein, A. (2007) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.05.021 · Cited by 96 · cited 1×
“Moreover, the hydrolysis in PCL can be further retarded by co-polymerizing with polymers like DL-lactide valerolactones, which significantly enhance its degradation time in physiological media [304].”
BackgroundBai, K., Zhang, Y., Fu, Z., Zhang, C., Cui, X., Meng, E., Guan, S., & Hu, J. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.12.102 · Cited by 96
Li, Z., Shizhao, S., Chen, M., Fahlman, B. D., Liu, D., & Bi, H. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.02.168 · Cited by 96
Kim, J., Shin, K.-H., Koh, Y., Hah, M. J., Moon, J., & Kim, H. (2017) · Materials · doi:10.3390/ma10101123 · Cited by 94
Electrophoretic Deposition (EPD): Fundamentals and Applications from Nano- to Microscale Structures
Amrollahi, P., Krasiński, J. S., Vaidyanathan, R. K., Tayebi, L., & Vashaee, D. (2015) · Springer eBooks · doi:10.1007/978-3-319-15266-0_7 · Cited by 93
Catauro, M., Bollino, F., Giovanardi, R., & Veronesi, P. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.12.046 · Cited by 92
Zai, W., Zhang, X., Su, Y., Man, H. C., Li, G., & Lian, J. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.125919 · Cited by 92
Li, C., Yu, C., Zeng, R., Zhang, B.-C., Cui, L., Wan, J., & Yang, X. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2019.12.001 · Cited by 92 · cited 1×
“[253] fabricated Ta2O5 nanofilm on MAO-coated AZ31 Mg alloy.”
MethodBiomimetic coating technology for orthopedic implants
Koju, N., Sikder, P., Ren, Y., Zhou, H., & Bhaduri, S. B. (2016) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2016.11.005 · Cited by 91 · cited 1×
“Additionally, polypeptides stimulate N- and C- terminal domains of non-collagen proteins (NCP), which act as potential binding sites for Ca and P ions along with essential trace elements [269,279].”
BackgroundZhang, Y., Huang, Y., Feyerabend, F., Blawert, C., Gan, W., Maawad, E., You, S., Gavras, S., Scharnagl, N., Bode, J., et al. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.11.050 · Cited by 90 · cited 1×
“37 V, which further accelerates the degradation phenomena in the presence of physiological media [13].”
BackgroundXu, Z., Ao, Z., Yang, M. L., & Wang, S. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127427 · Cited by 90
Research progress on surface protective coatings of biomedical degradable magnesium alloys
Liu, Y., Zhang, Y., Wang, Y., Tian, Y.-Q., & Chen, L. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.161001 · Cited by 89 · cited 1×
“At present, the most commonly used LbL coating formulations are polymer multilayers incorporated with healing agents [380].”
BackgroundTailoring degradation of AZ31 alloy by surface pre-treatment and electrospun PCL fibrous coating
Hanas, T., Kumar, T. S. S., Perumal, G., & Doble, M. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.04.017 · Cited by 89
Cheon, K., Park, C., Kang, M., Kang, I., Lee, M., Lee, H., Kim, H., Jung, H., & Jang, T. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.10.007 · Cited by 88 · cited 1×
“This surface coating method modifies the surface tribological characteristics, resulting in improved adhesion between the coating layer and substrate [179].”
MethodNear-infrared light controlled fast self-healing protective coating on magnesium alloy
Huang, L., Li, J., Yuan, W., Liu, X., Li, Z., Zheng, Y., Liang, Y., Zhu, S., Cui, Z., Yang, X., et al. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.108257 · Cited by 87
Jiang, W., Tian, Q., Vuong, T., Matthew, S., Chris, G., Sanders, T., & Liu, H. H. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00215 · Cited by 86 · cited 14×
“[121] C AZ31 PLGA PCL,Lev Dip 11–15 μm – Hank’s, 37 ◦C – – – – – – – Targeted drug release kinetics observed for levofloxacin.”
MethodInfluentialCoatings for biodegradable magnesium-based supports for therapy of vascular disease: A general view
Echeverry‐Rendón, M., Allain, J. P., Robledo, S. M., Echeverría, F., & Harmsen, M. C. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.04.032 · Cited by 84 · cited 1×
“Additionally, coatings with angiogenesis differentiation are highly recommended for the formation of new blood vessels from pre-existing vessels of host tissue at the early stages of implantation, which accelerates surgical wound-healing and osteoinduction response of implant [53,54].”
BackgroundZhang, W., Chen, Y., Chen, M., Zhao, S., Mao, J., Ai, Q., Li, W., Zhao, Y., Huang, N., & Wan, G. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.07.027 · Cited by 84
Wang, Y., Zhou, X., Yin, M., Pu, J., Yuan, N., & Ding, J. (2021) · Langmuir · doi:10.1021/acs.langmuir.1c00678 · Cited by 84
Lu, P., Fan, H., Liu, Y., Cao, L., Wu, X., & Xu, X. (2010) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2010.10.038 · Cited by 83
Wei, X., Liu, P., Ma, S., Li, Z., Peng, X., Deng, R., & Zhao, Q. B. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108729 · Cited by 83 · cited 1×
“The primary advantages like selective surface modification, low temperature, and reproducibility are significant for coating Mg alloys [180,181].”
BackgroundKaseem, M., & Ko, Y. G. (2020) · Composites Part B Engineering · doi:10.1016/j.compositesb.2020.108490 · Cited by 83
Dong, Q., Zhou, X., Feng, Y., Qian, K., Liu, H., Lu, M., Chu, C., Xue, F., & Bai, J. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.07.019 · Cited by 82 · cited 1×
“[378] developed a pH-sensitive dicalcium phosphate dihydrate (DCPD) coating on Pure Mg.”
BackgroundSong, Y., Tang, Y. B., Fang, L., Wu, F., Zeng, X., Hu, J., Zhang, S. F., Jiang, B., & Luo, H. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.03.013 · Cited by 80
Zhang, D., Cheng, S., Tan, J., Xie, J., Zhang, Y., Chen, S., Du, H., Qian, S., Qiao, Y., Peng, F., et al. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.01.032 · Cited by 79
Wei, Z., Tian, P., Liu, X., & Zhou, B. (2014) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2014.06.036 · Cited by 79 · cited 1×
“[361] fabricated a multilayered plasma electrolytic oxidation/poly(l-lactic acid)/Heparinized polydopamine (PEO/PLLA/PDAM/Hep) coating on AZ31 Mg alloy by a dip-coating method.”
MethodGrewal, N. S., Batra, U., Kumar, K., & Mahapatro, A. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.08.003 · Cited by 79 · cited 1×
“[372,373] fabricated a TiO2-HA-PCL hybrid coating on ZM21 Mg alloy, where TiO2-HA composite coating was applied as an inner layer.”
MethodSelf-citationZhao, Y., Zhang, Z., Shi, L., Zhang, F., Li, S., & Zeng, R. (2019) · Materials Letters · doi:10.1016/j.matlet.2018.11.069 · Cited by 78
Wang, J., Cui, L., Ren, Y., Zou, Y., Ma, J., Wang, C., Zheng, Z., Chen, X., Zeng, R., & Zheng, Y. (2020) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2020.02.006 · Cited by 78 · cited 1×
“Earlier investigations reported enhanced corrosion resistance and biocompatibility of SA towards Mg alloy [326,327].”
BackgroundBehavioral deficits and neural damage of Caenorhabditis elegans induced by three rare earth elements
Xu, T., Zhang, M., Hu, J., Li, Z., Wu, T., Bao, J., Wu, S., Lei, L., & He, D. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.04.068 · Cited by 77 · cited 1×
“Under chronic exposure, significant loss of dendrite and soma of neurons induced down-expressions and other behavioural deficits [6,100].”
BackgroundChen, S., Guan, S., Li, W., Wang, H., Chen, J., Wang, Y.-S., & Wang, H. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31982 · Cited by 77 · cited 1×
“[267] fabricated HA coating by ED on MAO treated Mg–Zn–Ca alloy.”
MethodPreparation of oriented collagen fiber scaffolds and its application in bone tissue engineering
Ma, C., Wang, H., Chi, Y., Wang, Y., Jiang, L., Xu, N., Wu, Q., Feng, Q., & Sun, X. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2020.100902 · Cited by 77 · cited 1×
“• Collagen (Col) is one of the most abundant polymers present inside the organic matrix of dentin, bone, tendons, and ligaments in the human body [316].”
BackgroundGuo, Y., Jia, S., Qiao, L., Su, Y., Gu, R., Li, G., & Lian, J. (2019) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.152782 · Cited by 77
Xun, X., Wan, Y., Zhang, Q., Gan, D., Hu, J., & Luo, H. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.144566 · Cited by 77
Chu, J. H., Sun, G., Tong, L., & Jiang, Z. (2021) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2021.126370 · Cited by 76 · cited 1×
“Additionally, the OCCs are widely explored for producing super-hydrophobic anion surfaces, which show significant corrosion resistance [114,115].”
BackgroundTuning of the Mg Alloy AZ31 Anodizing Process for Biodegradable Implants
Zaffora, A., Franco, F. D., Virtù, D., Pavia, F. C., Ghersi, G., Virtanen, S., & Santamaria, M. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22933 · Cited by 74 · cited 10×
“Additionally, Mg3(PO4)2 containing oxide layer show better cellular response for MC3T3-E1 cells compared to MgO layer.”
BackgroundInfluentialJana, A., Das, M., & Balla, V. K. (2021) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37297 · Cited by 74
Li, T., Ling, L., Lin, M., Jiang, Q., Lin, Q., Lou, C., & Lin, J. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110062 · Cited by 72 · cited 1×
“[262] evaluated the influence of variation in the current densities (i.”
BackgroundWu, G., Xu, R., Feng, K., Wu, S., Wu, Z., Sun, G., Zheng, G., Li, G., & Chu, P. K.-H. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.04.112 · Cited by 71
A self-healing coating containing curcumin for osteoimmunomodulation to ameliorate osseointegration
Li, B., Huang, R., Ye, J., Liu, L., Qin, L., Zhou, J., Zheng, Y., Wu, S., & Han, Y. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126323 · Cited by 71
Jian, S.-Y., Yang, C.-Y., & Chang, J.-K. (2020) · Applied Surface Science · doi:10.1016/j.apsusc.2020.145385 · Cited by 71 · cited 1×
“[94] proposed a novel Ce/Mn composite conversion coating for Elektron (EV) 31 Mg alloy with efficient corrosion resistance and self-healing features.”
BackgroundAbdal‐hay, A., Amna, T., & Lim, J. K. (2012) · Solid State Sciences · doi:10.1016/j.solidstatesciences.2012.11.017 · Cited by 70
Xiong, Y., Lü, C., Wang, C., & Song, R. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.10.103 · Cited by 69
Francis, A. A., Yang, Y., & Boccaccini, A. R. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.10.002 · Cited by 69
Yang, Y., Zheng, K., Liang, R., Mainka, A., Taccardi, N., Roether, J. A., Detsch, R., Goldmann, W. H., Virtanen, S., & Boccaccini, A. R. (2017) · Biomedical Materials · doi:10.1088/1748-605x/aa87f2 · Cited by 68
Kuang, J., Ba, Z., Li, Z., Jia, Y., & Wang, Z. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2019.01.009 · Cited by 67
Zhao, Y., Wu, G., Lu, Q., Wu, J. Y., Xu, R., Yeung, K., & Chu, P. K.-H. (2012) · Thin Solid Films · doi:10.1016/j.tsf.2012.05.046 · Cited by 66
Biomedical Alloys and Physical Surface Modifications: A Mini-Review
Yan, X., Cao, W., & Li, H. (2021) · Materials · doi:10.3390/ma15010066 · Cited by 66 · cited 1×
“PVD can be achieved by e-beam evaporation and Magnetron sputtering [231].”
MethodJamesh, M.-I., Wu, G., Zhao, Y., Jin, W., McKenzie, D. R., Bilek, M., & Chu, P. K.-H. (2014) · Corrosion Science · doi:10.1016/j.corsci.2014.05.020 · Cited by 65 · cited 1×
“[189] investigated the effects of dual ion Zr/N PIII coating on corrosion resistance of WE43 Mg alloy.”
BackgroundManne, B., Thiruvayapati, H., Bontha, S., Ramesh, M. R., Das, M., & Balla, V. K. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.05.017 · Cited by 65 · cited 1×
“laser surface melting (LSM) and laser shock peening (LSP) utilize the application of high temperature and pressure to obtain grain refinement [44].”
BackgroundDynamic degradation of porous magnesium under a simulated environment of human cancellous bone
Saad, A. P. M., Jasmawati, N., Harun, M. N., Kadir, M. R. A., Nur, H., Hermawan, H., & Syahrom, A. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.08.017 · Cited by 64
Application of novel sol–gel composites on magnesium alloy
Nezamdoust, S., Seifzadeh, D., & Rajabalizadeh, Z. (2019) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2019.03.004 · Cited by 62 · cited 1×
“Since, anodic oxidation coatings singularly cannot full fill diverse clinical demands several studies reported their combination with chemical conversion [174,175], electrodeposition [176], LDHs [177], sol-gel [178] coating techniques.”
BackgroundZhou, W., Hu, Z., Wang, T., Yang, G., Xi, W., Gan, Y., Lü, W., & Hu, J. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.110710 · Cited by 62 · cited 1×
“[281] modelled a Zn-doped nano-whisker HA coating on ZK 60 Mg alloy.”
Rare earth-based materials for bone regeneration: Breakthroughs and advantages
Huang, Y., Zhai, X., Ma, T., Zhang, M., Pan, H., Lu, W. W., Zhao, X., Sun, T., Li, Y., Shen, J., et al. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214236 · Cited by 62 · cited 1×
“They play a vital roles in the bio-functioning of the kidney, liver, skeletal muscles, and glands, indeed regulating the immune system by triggering anti-inflammatory reactions [90].”
BackgroundZhang, L., Xu, M., Hu, Y., Gao, F., Gong, T., Liu, T., Li, X., & Pan, C. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.04.235 · Cited by 62 · cited 1×
“The pH value of solution decides the density, thickness, and morphology of the coated layer [197].”
BackgroundCheng, M., Qiao, Y., Wang, Q., Qin, H., Zhang, X., & Liu, X. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.08.056 · Cited by 61
Yu, Y., Zhu, S., Dong, H., Zhang, X., Li, J., & Guan, S. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.06.015 · Cited by 61 · cited 1×
“Combining PDA with inorganic coatings like TiO2 and HA significantly enhances Mg alloy biocompatibility and corrosion resistance [308,309].”
BackgroundGuo, Y., Su, Y., Jia, S., Sun, G., Gu, R., Zhu, D., Li, G., & Lian, J. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.1171814jes · Cited by 61
Exploring the corrosion behavior of Mn-implanted biomedical Mg
Dong, Q., Jia, Y., Ba, Z., Tao, X., Wang, Z., Xue, F., & Bai, J. (2021) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.159739 · Cited by 59
Serum albumin level and long-term outcome in acute heart failure
Ancion, A., Allepaerts, S., Robinet, S., Oury, C., Piérard, L., & Lancellotti, P. (2019) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2018.1521557 · Cited by 58 · cited 1×
“• Serum-albumin (SA) is a major component of the circulatory system responsible for drug deposition and maintaining blood pressure [325].”
BackgroundUddin, M., Hall, C. J., Santos, V., Visalakshan, R. M., Qian, G., & Vasilev, K. A. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111459 · Cited by 58
Abdal‐hay, A., Dewidar, M., Lim, J., & Lim, J. K. (2013) · Ceramics International · doi:10.1016/j.ceramint.2013.07.142 · Cited by 58
Wu, H., Zhang, L., Zhang, Y., Long, S. L., & Jie, X. (2020) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2020.155107 · Cited by 57
Zhang, C., Zhang, S., Sun, D., Lin, J., Meng, F., & Liu, H. H. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.05.017 · Cited by 56
Chen, J., Liang, S., Fu, D., et al. (2020) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2020.154580 · Cited by 54
Structure and Corrosion Behavior of TiO2 Thin Films Deposited by ALD on a Biomedical Magnesium Alloy
Kania, A., Szindler, M., & Szindler, M. (2021) · Coatings · doi:10.3390/coatings11010070 · Cited by 54 · cited 1×
“This process is repeatedly carried out to increase coating thickness [244].”
BackgroundCui, X., Ning, C., Zhang, G., Shang, L., Zhong, L.-P., & Zhang, Y. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.04.009 · Cited by 54
Aquatic Toxicity Assessment of Phosphate Compounds
Kim, E., Yoo, S.-K., Ro, H.-Y., Han, H.-J., Baek, Y.-W., Eom, I., Kim, H.-M., Kim, P., & Choi, K. (2013) · Environmental Health and Toxicology · doi:10.5620/eht.2013.28.e2013002 · Cited by 53 · cited 1×
“However, the toxic potential of abruptly chelated phosphate compounds has not yet been fully explored [377].”
BackgroundLiu, Y., Li, H., Xu, J., TerBush, J. R., Li, W., Setty, M., Guan, S., Nguyen, T. D., Qin, L., & Zheng, Y. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127616 · Cited by 53 · cited 2×
“BAP is an idealized HA consisting of minor groups of CO3 , HPO4 , Na, Mg2+ and trace elements like Sr2+, K, F up to bio-safe ppm levels [274].”
BackgroundMethodZhao, N., & Zhu, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110420 · Cited by 52 · cited 1×
“[319] reported that fibrils on the Col-coated AZ31 Mg alloy were initiated only when the Col-1 monomer reached a particular concentration.”
BackgroundIn vitro corrosion of magnesium alloy AZ31 — a synergetic influence of glucose and Tris
Li, L., Liu, B., Zeng, R., Li, S., Zhang, F., Zou, Y.-H., Jiang, H. G., Chen, X., Guan, S., & Liu, Q. (2018) · Frontiers of Materials Science · doi:10.1007/s11706-018-0424-1 · Cited by 52 · cited 1×
“The excess of OH ions increases H2 evolution, which enhances the degradation rate of Mg substrate with prolonged immersion [199].”
BackgroundAdvances in layer-by-layer self-assembled coatings upon biodegradable magnesium alloys
He, L., Shao, Y., Li, S., Cui, L., Ji, X., Zhao, Y., & Zeng, R. (2021) · Science China Materials · doi:10.1007/s40843-020-1661-1 · Cited by 51 · cited 1×
“Various methods of depositing LbL coatings on Mg alloys are reported, including dip, spin, spray, and multistep methods [379].”
MethodThe anticorrosion mechanism of phenolic conversion coating applied on magnesium implants
Chen, S., Zhao, S., Chen, M., Zhang, X., Jiang, Z., Li, X., Zhang, H., Shen, X., Wang, J., & Huang, N. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.08.261 · Cited by 51
Xu, W. G., Yagoshi, K., Koga, Y., Sasaki, M., & Niidome, T. (2017) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2017.12.032 · Cited by 51
Xian, P., Chen, Y., Gao, S., Qian, J., Zhang, W., Udduttula, A., Huang, N., & Wan, G. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126282 · Cited by 51 · cited 1×
“Combining PDA with inorganic coatings like TiO2 and HA significantly enhances Mg alloy biocompatibility and corrosion resistance [308,309].”
BackgroundWang, F., Xia, D., Wang, S., Gu, R., Yang, F., Zhao, X., Liu, X., Zhu, Y., Liu, H., Xu, Y., et al. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.10.019 · Cited by 50 · cited 1×
“A primary reason for its application as a coating agent is its ability to promote an identical tissue structure on coated implants similar to natural bone [317].”
BackgroundDeeper inside the specificity of lysozyme when degrading chitosan. A structural bioinformatics study
Roman, D. L., Ostafe, V., & Isvoran, A. (2020) · Journal of Molecular Graphics and Modelling · doi:10.1016/j.jmgm.2020.107676 · Cited by 50
Fang, H., Wang, C., Zhou, S., Li, G., Tian, Y., & Suga, T. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.08.017 · Cited by 50
A Review on LDH-Smart Functionalization of Anodic Films of Mg Alloys
Kaseem, M., Ramachandraiah, K., Hossain, S., & Dikici, B. (2021) · Nanomaterials · doi:10.3390/nano11020536 · Cited by 49 · cited 11×
“This was more than twice as of Mg–Mn LDHs film, and ten times more than pure Mg substrate.”
BackgroundInfluentialYou, M., Echeverry‐Rendón, M., Zhang, L., Niu, J., Zhang, J., Jia, P., & Yuan, G. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111734 · Cited by 48 · cited 1×
“In contrast, some studies utilized it as a post-treatment technique to convert amorphous dicalcium phosphate dehydrate (DCPD) coatings to highly crystalline HA coatings, which efficiently shielded the Mg substrate in physiological media [3,141,201, 202].”
ResultFabrication of two distinct hydroxyapatite coatings and their effects on MC3T3-E1 cell behavior
Pang, S., He, Y., He, P., Luo, X., Guo, Z., & Li, H. (2018) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2018.06.046 · Cited by 48 · cited 1×
“and slight limitation on substrate shape compared to the ELD process [254,255].”
BackgroundWu, W., Sun, X. J., Zhu, C., Zhang, F., Zeng, R., Zou, Y.-H., & Li, S. (2020) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2020.105746 · Cited by 48
Colaço, É., Brouri, D., Méthivier, C., Valentin, L., Oudet, F., Kirat, K. E., Guibert, C., & Landoulsi, J. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.12.097 · Cited by 48 · cited 1×
“[278] investigated enzyme-induced Ca–P biomineralization using ALP extracted from the bovine intestinal mucosa.”
MethodWang, P. J., Liu, J., Luo, X., Xiong, P., Gao, S., Yan, J., Li, Y., Cheng, Y., & Xi, T. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01587f · Cited by 47
Tian, M., Cai, S., Ling, L., Zuo, Y., Wang, Z., Liu, P., Bao, X., & Xu, G. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.106745 · Cited by 47 · cited 1×
“A superhydrophobic HA/stearic acid composite coating [284] with a contact angle of 152 and a superhydrophilic HA/hydroxypropyltrimethyl chloride chitosan (HACC) composite coating [371] with a contact angle of 4 have been reported for their outstanding anti-bacterial properties.”
Fathyunes, L., & Khalil‐Allafi, J. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.12.133 · Cited by 47
Zhu, B., Wang, S., Wang, L., Yang, Y., Liang, J. Y., & Cao, B. (2017) · Coatings · doi:10.3390/coatings7070105 · Cited by 46
Fintová, S., Drábiková, J., Pastorek, F., Tkácz, J., Kuběna, I., Trško, L., Hadzima, B., Minda, J., Doležal, P., Wasserbauer, J., et al. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.10.038 · Cited by 46 · cited 2×
“Fluoride conversion coatings have limited bioactivity and poor stability with prolonged immersion in physiological media [69].”
BackgroundMethodHeakal, F. E., & Bakry, A. M. (2018) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2018.08.060 · Cited by 46
Jiang, Y., Wang, B., Jia, Z., Lu, X., Fang, L., Wang, K., & Ren, F. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36138 · Cited by 45
Ke, C., Song, M.-S., Zeng, R.-C., Qiu, Y., Zhang, Y., Zhang, R., Liu, R., Cole, I. S., Birbilis, N., & Chen, X. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.02.024 · Cited by 45
Barajas, J., Joya, J. C., Durán, K. S., Barrios, C. A. H., Coy, A. E., & Viejo, F. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2019.06.010 · Cited by 44 · cited 1×
“The coating procedure is typically performed by immersing Mg or Mg alloy substrates in 40%–48% hydrofluoric (HF) acid solution [69,105].”
MethodChen, C., Tan, J., Wu, W. G., Petrini, L., Zhang, L., Shi, Y., Cattarinuzzi, E., Jia, P., Huang, H., Ding, W., et al. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00700 · Cited by 44 · cited 1×
“737 but the outcomes still do not fulfill the clinical requirements [301, 302].”
BackgroundRecent Advances in Anti-inflammatory Strategies for Implantable Biosensors and Medical Implants
Lee, D., Park, K., & Seo, J. (2020) · BioChip Journal · doi:10.1007/s13206-020-4105-7 · Cited by 44 · cited 1×
“In any case, the coating must produce an efficient anti-inflammatory response, necessary for the first 3–7 days of implantation [52].”
BackgroundRahimi, M., Aghdam, R. M., Sohi, M. H., Rezayan, A. H., & Ettelaei, M. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126627 · Cited by 43 · cited 1×
“[283] developed electrospun chitosan/mineralized bone allograft (MBA) nanocoating on AZ31 Mg alloy for enhanced bone regeneration ability.”
BackgroundLi, Q., Bao, X., Sun, J., Cai, S., Xie, Y., Liu, Y., Liu, J. S., & Xu, G. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-05592-5 · Cited by 43
Wan, H.-Y., Shin, R. L.-Y., Chen, J. C. H., Assunção, M., Wang, D. M., Nilsson, S. K., Tuan, R. S., & Blocki, A. M. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.11.049 · Cited by 42 · cited 1×
“Apart from molecular recognition, enzymatic mineralization and molecular crowding techniques are effectively reported for rapid mimicking of natural bone [276,277].”
BackgroundHighly Mineralized Biomimetic Polysaccharide Nanofiber Materials Using Enzymatic Mineralization
Yao, J., Fang, W., Guo, J., Jiao, D., Chen, S., Ifuku, S., Wang, H., & Walther, A. (2020) · Biomacromolecules · doi:10.1021/acs.biomac.0c00160 · Cited by 42 · cited 1×
“Apart from molecular recognition, enzymatic mineralization and molecular crowding techniques are effectively reported for rapid mimicking of natural bone [276,277].”
BackgroundJian, S.-Y., Tzeng, Y., Ger, M.-D., Chang, K.-L., Shi, G.-N., Huang, W.-H., Chen, C.-Y., & Wu, C.-C. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.108707 · Cited by 42
Peron, M., Afif, A. B., Dadlani, A. L., Berto, F., & Torgersen, J. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.125922 · Cited by 42
Zhang, H., Xie, L., Shen, X.-L., Shang, T., Luo, R., Li, X., You, T.-X., Wang, J., Huang, N., & Wang, Y.-B. (2018) · Journal of materials chemistry. B · doi:10.1039/c8tb01574k · Cited by 41
Grewal, N. S., Batra, U., Kumar, K., & Mahapatro, A. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.10.004 · Cited by 41
Self-citationSaranya, K., Kalaiyarasan, M., & Rajendran, N. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2019.124902 · Cited by 41 · cited 1×
“[92] investigated the role of selenium (Se) conversion coating on AZ31 Mg alloy for bio-mineralization and anti-bacterial response.”
Background
Cited by
Advances in orthodontic clear aligner materials
Bichu, Y. M., Alwafi, A., Liu, X., Andrews, J., Ludwig, B., Bichu, A. Y., & Zou, B. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.10.006 · Cited by 274
Zhao, Y., He, P., Wang, B., Bai, J., Xue, F., & Chu, C. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.12.004 · Cited by 60
Qi, G., Ma, T., Wang, Y., Chen, K., Yan, Y., Li, Z., Deng, N., Tseng, C., Li, B., Zheng, Y., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-72683-3 · Cited by 2
Metadata
- Authors
- Singh, N., Batra, U., Kumar, K., Ahuja, N., & Mahapatro, A.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2023-01
- Volume
- 19
- Pages
- 717-757
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W4280611586
- Cited by
- 165
- References
- 250
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.