The DOI matches its Crossref record; 126 of the 127 references it cites were found in a registry or an index.
Challenges for successful implantation of biofuel cells
Open accessAbstract
There is a growing interest in the design and engineering of operational biofuel cells that can be implanted. This review highlights the recent progress in the electrochemistry of biofuel cell technologies, but with a particular emphasis on the medical and physiological aspects that impact the biocompatibility of biofuel cells operating inside a living body. We discuss the challenge of supplying power to implantable medical devices, with regard to the limitations of lithium battery technology and why implantable biofuel cells can be a promising alternative to provide the levels of power required for medical devices. In addition to the challenge of designing a biofuel cell that provides a stable level of sufficient power, the review highlights the biocompatibility and biofouling problems of implanting a biofuel cell that have a major impact on the availability of the substrates inside body that provide fuel for the biofuel cell. These physiological challenges and associated ethical considerations are essential to consider for biofuel cells that are designed to be implanted for long-term operation inside a living animal and eventually to human clinical applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although Li/I2 batteries have been successfully used in cardiac pacemakers due to their high discharge voltages reaching up to 3.6 V and impressive energy densities of 210 and 810 W h/L, they are not directly applicable to brain implants (Zebda et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Zebda et al., 2018
In the citing paper
“Although Li/I2 batteries have been successfully used in cardiac pacemakers due to their high discharge voltages reaching up to 3.6 V and impressive energy densities of 210 and 810 W h/L, they are not directly applicable to brain implants (Zebda et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Zebda et al., 2018
Citations
Cites
The Principles of Humane Experimental Technique
(1960) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1960.tb73127.x · Cited by 5,045
(2010) · Cited by 1,697
Guyton and Hall: Textbook of Medical Physiology
Khonsary, S. A. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,427
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Barton, S. C., Gallaway, J., & Atanassov, P. B. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,396
Enzyme stability and stabilization—Aqueous and non-aqueous environment
Iyer, P. V., & Ananthanarayan, L. (2008) · Process Biochemistry · doi:10.1016/j.procbio.2008.06.004 · Cited by 1,114
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033
Vullers, R. J. M., van Schaijk, R. T. F., Doms, I., Hoof, C. A. V., & Mertens, R. (2009) · Solid-State Electronics · doi:10.1016/j.sse.2008.12.011 · Cited by 889
(2007) · Elsevier eBooks · doi:10.1016/b978-0-444-51958-0.x5000-9 · Cited by 816
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Zoski, C. G. (2006) · Cited by 671
Research works printed but not linked: 3
- Li, 1990, Lithium iodine batteries used in pacemaker, Chin. J. Power Sourc., 1, 5
- Giner, 1973, Eine implantierbare Brennstoffzelle zum Betrieb eines mechanischen Herzens Berichte der Bunsen-Gesellchaft, Phys. Chem., 77
- Pankratov, 2014, Self-charging electrochemical biocapacitor, ChemElectroChem, 1, 343, 10.1002/celc.201300142 · DOI
Cited by
Sorted by citations
Items 201–224 of 224
功, 四., & Tsujimura, S. (2019) · Denki Kagaku · doi:10.5796/denkikagaku.19-fe0028
Emerging in vivo power supply strategies for implantable electronics
Tao, Z., Wang, B., & Wang, Y. (2022) · International Conference on Computer, Artificial Intelligence and Control Engineering (CAICE) · doi:10.1117/12.2641930
Prospecção e análise do cluster biofuel cell
da Cruz, M. D. O., & Junior, F. G. D. S. (2022) · Conferência Brasileira de Planejamento Experimental e Análise de Dados (ConBraPA) · doi:10.29327/conbrapa2022.523381
Electrochemical Devices | Bioelectrochemical Cells and Microbial Fuel Cells
Schröder, U. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96022-9.00030-x
Biosensors and Biofuel Cells Based on Porous Carbon with Mesopores/Macropores Suitable for Enzymes
Shitanda, I., & Tsujimura, S. (2023) · Denki Kagaku · doi:10.5796/denkikagaku.23-fe0002
Green Synthesis of Nanomaterials and Their Characterization in Relation to Biofuel Production
Yadav, A., Srivastava, A., Jangid, N. K., Makhija, A., Sharma, A., & Srivastava, M. C. (2025) · Clean Energy Production Technologies · doi:10.1007/978-981-96-1706-7_9
Nanostructured Systems and the Value of Biological Engineering
Martin, D. K., & Vilgrain, I. (2025) · Springer eBooks · doi:10.1007/978-3-031-90594-0_2
Self-citationWhere Does Biomimetic Membrane Technology Fit into Biological Engineering?
Martin, D. K., & Vilgrain, I. (2025) · Springer eBooks · doi:10.1007/978-3-031-90594-0_4
Self-citationA Conductive Hydrogel-based Biofuel Cell Installed in Stent for Endoprothesis
Vakhnitskaya, E., Parunova, Y. M., & Gotovtsev, P. M. (2025) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit65494.2025.11054154
Dai, H., Chen, G., Mu, J., Afreen, S., Liu, L., Wang, F., Dong, S., Men, X., Wang, L., & Zhang, H. (2025) · Biotechnology Journal · doi:10.1002/biot.70090
Korkut, S., Kılıç, M. S., & Uru, M. K. (2025) · Ionics · doi:10.1007/s11581-025-06830-z
Low-carbon Fuel Cell Materials
de Souza, F. M., & Gupta, R. K. (2026) · Royal Society of Chemistry eBooks · doi:10.1039/9781837676064-00065
Exploration des transferts d'électrons entre cellules animales et électrodes
Guette-Marquet, S. (2021) · theses.fr (ABES) · doi:10.70675/19889b5az6883z4990zb4dazce5281db7151
Fabrication et optimisation de bioelectrodes abiotiques pour biopiles à glucose implantables
Ghodhbane, M. (2021) · theses.fr (ABES) · doi:10.70675/4c8b3801zb000z4840za7a8zcb61ae77d7d1
Ballestas, F. R. F. (2023) · theses.fr (ABES) · doi:10.70675/bb5b27d2z9a55z471cz98aez6b458b7664ab
Milam, A., Intano, J., & Minteer, S. D. (2026) · Green Chemistry · doi:10.1039/d6gc01795a
Self-citationPatra, S., & Boisen, A. (2026) · Royal Society of Chemistry eBooks · doi:10.1039/9781837679850-00304
Liu, Z., Ge, J., Jin, J., Wu, C., Wang, K., Huang, Q., Wang, Q., Zhang, Z., Tian, B., & Jiang, Z. (2026) · iScience · doi:10.1016/j.isci.2026.117418
Muhammad, M., Oguntala, G., & Yinusa, A. (2026) · Nano Biomedicine and Engineering · doi:10.1016/j.nbe.2026.100079
Biodiesel synthesis and biohydrogen production of green microbial nanotechnology for green energy
Sadeghi-kaji, S., & Homaei, A. A. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-43968-1.00013-9
Development and status of electrochemical engineering
Bergel, A., Bergmann, H., Bouzek, K., Ferreira, M. G. S., Kelsall, G. H., Krewer, U., Kreysa, G., Lapicque, F., Paidar, M., Prokop, M., et al. (2026) · Electrochimica Acta · doi:10.1016/j.electacta.2026.150160
Metadata
- Authors
- Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Queen Mary University of London (GB)
- Malmö University (SE)
- University of Utah (US)
- Corresponding author
- Martin, Donald K.
- ORCID
- Venue
- Bioelectrochemistry
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 124
- Pages
- 57-72
- ISSN
- 1567-5394 (ISSN-L)
- OpenAlex
- W2808838311
- Cited by
- 224
- References
- 127
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 23 · 2023: 33 · 2022: 29 · 2021: 44 · 2020: 32 · 2019: 25 · 2018: 6
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Bioelectrochemistry (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by-nc-nd)
- KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
- Malmö University Publications (Malmö University) (submittedVersion)
- Queen Mary Research Online (Queen Mary University of London) (submittedVersion, cc-by)
- Funders
- Vetenskapsrådet (621-2013-6006)
- Engineering and Physical Sciences Research Council (EP/H009744/1)
- Agence Nationale de la Recherche (ANR-15-CE05-0003-01)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Keywords
- implantable biofuel cells, biocompatibility, biofouling, biomedical implants, ethical considerations, long-term implantation
- MeSH terms
- Animals, Biocompatible Materials, Bioelectric Energy Sources, Electrodes, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review