The DOI matches its Crossref record; 126 of the 127 references it cites were found in a registry or an index.
Challenges for successful implantation of biofuel cells
Open accessAbstract
There is a growing interest in the design and engineering of operational biofuel cells that can be implanted. This review highlights the recent progress in the electrochemistry of biofuel cell technologies, but with a particular emphasis on the medical and physiological aspects that impact the biocompatibility of biofuel cells operating inside a living body. We discuss the challenge of supplying power to implantable medical devices, with regard to the limitations of lithium battery technology and why implantable biofuel cells can be a promising alternative to provide the levels of power required for medical devices. In addition to the challenge of designing a biofuel cell that provides a stable level of sufficient power, the review highlights the biocompatibility and biofouling problems of implanting a biofuel cell that have a major impact on the availability of the substrates inside body that provide fuel for the biofuel cell. These physiological challenges and associated ethical considerations are essential to consider for biofuel cells that are designed to be implanted for long-term operation inside a living animal and eventually to human clinical applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although Li/I2 batteries have been successfully used in cardiac pacemakers due to their high discharge voltages reaching up to 3.6 V and impressive energy densities of 210 and 810 W h/L, they are not directly applicable to brain implants (Zebda et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Zebda et al., 2018
In the citing paper
“Although Li/I2 batteries have been successfully used in cardiac pacemakers due to their high discharge voltages reaching up to 3.6 V and impressive energy densities of 210 and 810 W h/L, they are not directly applicable to brain implants (Zebda et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Zebda et al., 2018
Citations
Cites
The Principles of Humane Experimental Technique
(1960) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1960.tb73127.x · Cited by 5,045
(2010) · Cited by 1,697
Guyton and Hall: Textbook of Medical Physiology
Khonsary, S. A. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,427
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Barton, S. C., Gallaway, J., & Atanassov, P. B. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,396
Enzyme stability and stabilization—Aqueous and non-aqueous environment
Iyer, P. V., & Ananthanarayan, L. (2008) · Process Biochemistry · doi:10.1016/j.procbio.2008.06.004 · Cited by 1,114
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033
Vullers, R. J. M., van Schaijk, R. T. F., Doms, I., Hoof, C. A. V., & Mertens, R. (2009) · Solid-State Electronics · doi:10.1016/j.sse.2008.12.011 · Cited by 889
(2007) · Elsevier eBooks · doi:10.1016/b978-0-444-51958-0.x5000-9 · Cited by 816
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Zoski, C. G. (2006) · Cited by 671
Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
Zebda, A., Gondran, C., Goff, A. L., Holzinger, M., Cinquin, P., & Cosnier, S. (2011) · Nature Communications · doi:10.1038/ncomms1365 · Cited by 615
Self-citationMano, N., Mao, F., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0346328 · Cited by 590
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Implanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Enzymatic fuel cells: Recent progress
Leech, D., Kavanagh, P., & Schuhmann, W. W. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.02.087 · Cited by 445
Chen, T., Barton, S. C., Binyamin, G. N., Gao, Z., Zhang, Y., Kim, H.-H., & Heller, A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0163164 · Cited by 427
Tissue reaction to three ceramics of porous and non‐porous structures
Hulbert, S., Morrison, S. J., & Klawitter, J. J. (1972) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820060505 · Cited by 423
A Glucose BioFuel Cell Implanted in Rats
Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F. R., Alcaraz, J., Gorgy, K., Lenouvel, F., Mathé, S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010476 · Cited by 413
Self-citationTheory of oxygen transport to tissue.
Popel, A. S. (1989) · PubMed · Cited by 398
Cao, L., Liu, X., Lin, E.-J. D., Wang, C., Choi, E., Riban, V., Lin, B., & During, M. J. (2010) · Cell · doi:10.1016/j.cell.2010.05.029 · Cited by 378
Single Glucose Biofuel Cells Implanted in Rats Power Electronic Devices
Zebda, A., Cosnier, S., Alcaraz, J., Holzinger, M., Goff, A. L., Gondran, C., Boucher, F. R., Giroud, F., Gorgy, K., Lamraoui, H., et al. (2013) · Scientific Reports · doi:10.1038/srep01516 · Cited by 372
Self-citationDevelopment of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
From “cyborg” lobsters to a pacemaker powered by implantable biofuel cells
MacVittie, K., Halámek, J., Halámková, L., Southcott, M. A., Jemison, W. D., Lobel, R. M., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee23209j · Cited by 332
Anti-fouling bioactive surfaces
Yu, Q., Zhang, Y., Wang, H., Brash, J. L., & Chen, H. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.021 · Cited by 327
Batteries used to power implantable biomedical devices
Bock, D. C., Marschilok, A. C., Takeuchi, K. J., & Takeuchi, E. S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.057 · Cited by 319
Palmore, G. T. R., Bertschy, H., Bergens, S. H., & Whitesides, G. M. (1998) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00393-8 · Cited by 315
Why Enzymes Are Proficient Catalysts: Beyond the Pauling Paradigm
Zhang, X., & Houk, K. N. (2005) · Accounts of Chemical Research · doi:10.1021/ar040257s · Cited by 304
The facilitated component of intestinal glucose absorption
Kellett, G. L. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0585h.x · Cited by 294
Implantable Cardioverter–Defibrillators
Dimarco, J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 294
Towards glucose biofuel cells implanted in human body for powering artificial organs: Review
Cosnier, S., Goff, A. L., & Holzinger, M. (2013) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.09.021 · Cited by 291
Regulation of intestinal sugar transport
Ferraris, R. P., & Diamond, J. M. (1997) · Physiological Reviews · doi:10.1152/physrev.1997.77.1.257 · Cited by 277
An Implantable Biofuel Cell for a Live Insect
Rasmussen, M., Ritzmann, R. E., Lee, I., Pollack, A. J., & Scherson, D. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210794c · Cited by 271
Living battery – biofuel cells operating in vivo in clams
Szczupak, A., Halámek, J., Halámková, L., Bocharova, V., Alfonta, L., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21626d · Cited by 259
Akers, N. L., Moore, C. M., & Minteer, S. D. (2004) · Electrochimica Acta · doi:10.1016/j.electacta.2004.10.080 · Cited by 255
Self-citationA Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038436 · Cited by 251
Enzymatic biofuel cells designed for direct power generation from biofluids in living organisms
Miyake, T., Haneda, K., Nagai, N., Yatagawa, Y., Onami, H., Yoshino, S., Abe, T., & Nishizawa, M. (2011) · Energy & Environmental Science · doi:10.1039/c1ee02200h · Cited by 247
Engineering the tissue which encapsulates subcutaneous implants. I. Diffusion properties
Sharkawy, A. A., Klitzman, B. M., Truskey, G. A., & Reichert, W. M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 239
Implanted biofuel cells operating in vivo – methods, applications and perspectives – feature article
Katz, E., & MacVittie, K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42126k · Cited by 234
BIOELECTROCHEMISTRY. I. ENZYME UTILIZING BIO-FUEL CELL STUDIES.
Yahiro, A. T., Lee, S. M., & Kimble, D. O. (1964) · PubMed · Cited by 215
Biofuel cell as a power source for electronic contact lenses
Falk, M., Andoralov, V., Blum, Z., Sotres, J., Suyatin, D. B., Ruzgas, T. A., Arnebrant, T., & Shleev, S. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.04.030 · Cited by 215
Self-citationCellobiose Dehydrogenase: A Versatile Catalyst for Electrochemical Applications
Ludwig, R., Harreither, W., Tasca, F., & Gorton, L. G. O. (2010) · ChemPhysChem · doi:10.1002/cphc.201000216 · Cited by 191
Power sources and electrical recharging strategies for implantable medical devices
Wei, X., & Liu, J. (2008) · Frontiers of Energy and Power Engineering in China · doi:10.1007/s11708-008-0016-3 · Cited by 189
(2011) · PubMed · Cited by 187
Energy Harvesting and Remote Powering for Implantable Biosensors
Olivo, J., Carrara, S., & Micheli, G. D. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2085042 · Cited by 167
Energy scavenging sources for biomedical sensors
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/r01 · Cited by 165
Guo, S., Jańczewski, D., Zhu, X., Quintana, R., He, T., & Neoh, K. G. (2015) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2015.04.013 · Cited by 158
Use of nanotopography to study mechanotransduction in fibroblasts – methods and perspectives
Dalby, M. J., Riehle, M. O., Sutherland, D. S., Agheli, H., & Curtis, A. S. G. (2004) · European Journal of Cell Biology · doi:10.1078/0171-9335-00369 · Cited by 150
Sales, F. C. P. F., Iost, R. M., Martins, M. V. A., Almeida, M. C., & Crespilho, F. N. (2012) · Lab on a Chip · doi:10.1039/c2lc41007a · Cited by 142
Schreml, S., Meier, R. J., Kirschbaum, M., Kong, S. C., Gehmert, S., Felthaus, O., Hedtrich, S., Sharpe, J. R., Wöltje, K., Weiß, K. T., et al. (2014) · Theranostics · doi:10.7150/thno.9052 · Cited by 142
Biofuel Cell Operating in Vivo in Rat
Castorena‐Gonzalez, J. A., Foote, C. A., MacVittie, K., Halámek, J., Halámková, L., Martinez‐Lemus, L. A., & Katz, E. (2013) · Electroanalysis · doi:10.1002/elan.201300136 · Cited by 139
Babadi, A. A., Bagheri, S., & Hamid, S. B. A. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.016 · Cited by 138
Agnès, C., Holzinger, M., Goff, A. L., Reuillard, B., Elouarzaki, K., Tingry, S., & Cosnier, S. (2014) · Energy & Environmental Science · doi:10.1039/c3ee43986k · Cited by 134
Ethical scores for animal experiments
Porter, D. G. (1992) · Nature · doi:10.1038/356101a0 · Cited by 134
Zafar, M. N., Beden, N., Leech, D., Sygmund, C., Ludwig, R., & Gorton, L. G. O. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5650-7 · Cited by 124
Focal Controlled Drug Delivery
Domb, A. J., & Khan, W. (2014) · Advances in delivery science and technology · doi:10.1007/978-1-4614-9434-8 · Cited by 122
A microbial fuel cell as power supply for implantable medical devices
Han, Y., Yu, C., & Liu, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.02.014 · Cited by 118
Khan, W., Muntimadugu, E., Jaffé, M., & Domb, A. J. (2013) · Advances in delivery science and technology · doi:10.1007/978-1-4614-9434-8_2 · Cited by 114
The physiology of oxygen transport
Habler, O. P., & Messmer, K. F. W. (1997) · Transfusion Science · doi:10.1016/s0955-3886(97)00041-6 · Cited by 113
Remote wireless control of an enzymatic biofuel cell implanted in a rabbit for 2 months
Ichi, S. E., Alcaraz, J., Boucher, F. R., Boutaud, B., Molin, R. D., Boutonnât, J., Cinquin, P., Zebda, A., & Martin, D. K. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.02.156 · Cited by 112
Self-citationRecent advances in the design of titanium alloys for orthopedic applications
Guillemot, F. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.6.741 · Cited by 111
Modulation Techniques for Biomedical Implanted Devices and Their Challenges
Hannan, M. A., Abbas, S. M., Samad, S. A., & Hussain, A. (2011) · Sensors · doi:10.3390/s120100297 · Cited by 110
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107
A wireless transmission system powered by an enzyme biofuel cell implanted in an orange
MacVittie, K., Conlon, T., & Katz, E. (2014) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2014.10.005 · Cited by 107
Heparin coating of the stent graft — effects on platelets, coagulation and complement activation
Christensen, K., Larsson, R. L., Emanuelsson, H., Elgue, G., & Larsson, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00190-3 · Cited by 107
Biomembrnanes as models for polymer surfaces
Durrani, A. A., Hayward, J. A., & Chapman, D. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90068-2 · Cited by 102
Miniature Biofuel Cells with Improved Stability Under Continuous Operation
Fischback, M. B., Youn, J. K., Zhao, X. S., Wang, P., Park, H. G., Chang, H. N., Kim, J., & Ha, S. (2006) · Electroanalysis · doi:10.1002/elan.200603626 · Cited by 101
Milton, R. D., Lim, K., Hickey, D. P., & Minteer, S. D. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.04.005 · Cited by 99
Self-citationBiofuel Cells for Biomedical Applications: Colonizing the Animal Kingdom
Falk, M., Villarrubia, C. W. N., Babanova, S., Atanassov, P. B., & Shleev, S. (2013) · ChemPhysChem · doi:10.1002/cphc.201300044 · Cited by 98
Self-citationSelf‐Charging Electrochemical Biocapacitor
Pankratov, D., Blum, Z., Suyatin, D. B., Popov, V. O., & Shleev, S. (2013) · ChemElectroChem · doi:10.1002/celc.201300142 · Cited by 98
Self-citationEnzymatic biofuel cells utilizing a biomimetic cofactor
Campbell, E., Meredith, M. T., Minteer, S. D., & Banta, S. A. (2011) · Chemical Communications · doi:10.1039/c2cc16156g · Cited by 96
Self-citationBioelectrodes modified with chitosan for long-term energy supply from the body
Ichi, S. E., Zebda, A., Alcaraz, J., Laaroussi, A., Boucher, F. R., Boutonnât, J., Reverdy-Bruas, N., Chaussy, D., Belgacem, M. N., Cinquin, P., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03430a · Cited by 95
Self-citationA wireless near-infrared energy system for medical implants
Murakawa, K., Kobayashi, M., Nakamura, O., & Kawata, S. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.805148 · Cited by 87
Stoica, L., Dimcheva, N. D., Ackermann, Y., Karnicka, K., Guschin, D. A., Kulesza, P. J., Rogalski, J., Haltrich, D., Ludwig, R., Gorton, L., et al. (2009) · Fuel Cells · doi:10.1002/fuce.200800033 · Cited by 83
Andoralov, V., Falk, M., Suyatin, D. B., Granmo, M., Sotres, J., Ludwig, R., Popov, V. O., Schouenborg, J., Blum, Z., & Shleev, S. (2013) · Scientific Reports · doi:10.1038/srep03270 · Cited by 83
Self-citationShrayyef, M. Z., & Gerich, J. E. (2009) · Springer eBooks · doi:10.1007/978-0-387-09841-8_2 · Cited by 74
Meyer, C., Stümvoll, M., Welle, S. L., Woerle, H. J., Haymond, M. W., & Gerich, J. E. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00145.2003 · Cited by 73
ROLE OF CARBOHYDRATE IN PHYSICAL ACTIVITY
Ivy, J. L. (1999) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(05)70162-9 · Cited by 72
A hybrid electric power device for simultaneous generation and storage of electric energy
Pankratov, D., Falkman, P., Blum, Z., & Shleev, S. (2013) · Energy & Environmental Science · doi:10.1039/c3ee43413c · Cited by 72
Self-citationRaatikainen, M. J. P., Arnar, D. O., Merkely, B. P., Camm, A. J., & Hindricks, G. (2016) · EP Europace · doi:10.1093/europace/euw244 · Cited by 71
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71
Enzyme Stabilization and Immobilization
(2016) · Methods in molecular biology · doi:10.1007/978-1-4939-6499-4 · Cited by 67
Bioelectrochemical application of some PQQ-dependent enzymes
Laurinavičius, V., Razumienė, J., Kurtinaitienė, B., Lapėnaitė, I., Bachmatova, I., Marcinkevičienė, L., Meškys, R., & Ramanavičius, A. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00128-1 · Cited by 66
Hybrid Electric Power Biodevices
Pankratov, D., Blum, Z., & Shleev, S. (2014) · ChemElectroChem · doi:10.1002/celc.201402158 · Cited by 64
Self-citationCerebral autoregulation and gas exchange studied using a human cardiopulmonary model
Lu, K., Clark, J. W., Ghorbel, F. H., Robertson, C. S., Ware, D. L., Zwischenberger, J. B., & Bidani, A. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00594.2003 · Cited by 63
Treu, B. L., & Minteer, S. D. (2008) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2008.07.005 · Cited by 62
Self-citationDong, K., Jia, B., Yu, C., Dong, W., Du, F., & Hong, L. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.10.028 · Cited by 61
Evolution of power sources for implantable cardioverter defibrillators
Crespi, A. M., Somdahl, S. K., Schmidt, C., & Skarstad, P. M. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00499-2 · Cited by 61
Highly stable enzyme precipitate coatings and their electrochemical applications
Kim, B. C., Zhao, X., Ahn, H., Kim, J. H., Lee, H.-J., Kim, K. W., Nair, S., Hsiao, E., Jia, H., Oh, M., et al. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.068 · Cited by 58
Novak, M. T., Yuan, F., & Reichert, W. M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4097-6 · Cited by 55
Biosupercapacitors for powering oxygen sensing devices
Kizling, M., Dramińska, S., Stolarczyk, K., Tammela, P., Wang, Z., Nyholm, L., & Bilewicz, R. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.04.012 · Cited by 53
Scheiblbrandner, S., Breslmayr, E., Csarman, F., Paukner, R., Führer, J., Herzog, P. L., Shleev, S., Osipov, E. M., Tikhonova, T. V., Popov, V. O., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-13734-0 · Cited by 51
Self-citationA Linear Permanent Magnet Generator for Powering Implanted Electronic Devices
Nasiri, A., Zabalawi, S. A., & Jeutter, D. C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2055891 · Cited by 48
The ethical acceptability of animal experiments: a proposal for a system to support decision-making
Stafleu, F. R., Tramper, R., Vorstenbosch, J., & Joles, J. A. (1999) · Laboratory Animals · doi:10.1258/002367799780578255 · Cited by 48
Principles of Diabetes Mellitus
Mannucci, E. (2010) · JAMA · doi:10.1001/jama.2010.1469 · Cited by 46
Biofuel cell anode: NAD+/glucose dehydrogenase-coimmobilized ketjenblack electrode
Miyake, T., Oike, M., Yoshino, S., Yatagawa, Y., Haneda, K., Kaji, H., & Nishizawa, M. (2009) · Chemical Physics Letters · doi:10.1016/j.cplett.2009.08.075 · Cited by 44
Gupta, N., Kiley, M. L., Anthony, F. F., Young, C., Brar, S. S., & Kwaku, K. F. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002798 · Cited by 44
Hemoglobin-Based Oxygen Carriers as Red Cell Substitutes and Oxygen Therapeutics
Kim, H. W., & Greenburg, A. (2013) · Springer eBooks · doi:10.1007/978-3-642-40717-8 · Cited by 43
Effects of mast cell modulation on early host response to implanted synthetic meshes
Orenstein, S. B., Saberski, E. R., Klueh, U., Kreutzer, D. L., & Novitsky, Y. W. (2010) · Hernia · doi:10.1007/s10029-010-0680-1 · Cited by 42
Tombs, M. P. (1985) · PubMed · Cited by 41
The Lithium/Iodine Battery: A Historical Perspective
Greatbatch, W., & Holmes, C. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb03016.x · Cited by 38
Ross, E. A., Batich, C. D., Clapp, W. L., Sallustio, J. E., & Lee, N. C. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00764.x · Cited by 36
Changing Trends in Pacemaker and Implantable Cardioverter Defibrillator Generator Advisories
Maisel, W. H., Stevenson, W. G., & Epstein, L. M. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01670.x · Cited by 35
Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors
Vallejo-Heligon, S. G., Klitzman, B. M., & Reichert, W. M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.019 · Cited by 34
Murtha, S. J. E., Pappas, B. A., & Raman, S. (1990) · Behavioural Brain Research · doi:10.1016/0166-4328(90)90031-9 · Cited by 30
Blood compatibility of polymers derived from natural materials
Fedel, M., Tanır, T. E., Hasırcı, N., Maniglio, D., Morelli, A., Chiellini, E., & Motta, A. (2012) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911512446060 · Cited by 30
Velho, G., Froguel, P., & Reach, G. (1989) · Diabetologia · doi:10.1007/bf00277254 · Cited by 28
Ichi, S. E., Zebda, A., Tingry, S., Petit, M., Suherman, A. L., Boualam, A., Cinquin, P., & Martin, D. K. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.05.018 · Cited by 28
Self-citationZhong, Q., Yan, J., Xu, Q., Zhang, T., Zhang, Z., & Li, A. (2014) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2014.06.022 · Cited by 26
Ayato, Y., Sakurai, K., Fukunaga, S., Suganuma, T., Yamagiwa, K., Shiroishi, H., & Kuwano, J. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.063 · Cited by 24
Biological fuel cells: Divergence of opinion
Shleev, S., Bergel, A., & Gorton, L. G. O. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.07.006 · Cited by 22
Self-citationEnzyme Stability and Stabilisation: Applications and Case Studies
Drago, G. A., & Gibson, T. D. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-46889-1_24 · Cited by 21
Implantable Cardioverter Defibrillators
Nasir, A. M. Z. R., Batra, R., & Jayasinghe, R. (2008) · Australasian Medical Journal · doi:10.4066/amj.2010.129 · Cited by 20
Optimization of the Oxygen Transport System
Pennock, B. E., & Attinger, E. O. (1968) · Biophysical Journal · doi:10.1016/s0006-3495(68)86526-9 · Cited by 19
Power Generation from Human Leukocytes/Lymphocytes in Mammalian Biofuel Cell
Güven, G., Lozano-Sánchez, P., & Güven, A. (2013) · International Journal of Electrochemistry · doi:10.1155/2013/706792 · Cited by 16
From the Atmosphere to the Mitochondrion: The Oxygen Cascade
Biro, G. P. (2013) · Springer eBooks · doi:10.1007/978-3-642-40717-8_2 · Cited by 15
Implantable cardioverter-defibrillators: indications and unresolved issues.
Kedia, R., & Saeed, M. (2012) · PubMed Central · Cited by 12
Percutaneous Window Chamber Method for Chronic Intravital Microscopy of Sensor—Tissue Interactions
Koschwanez, H. E., Klitzman, B., & Reichert, W. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200608 · Cited by 9
Advances in Lithium and Nickel-Metal Hydride Battery Performance
Oman, H. (1999) · MRS Bulletin · doi:10.1557/s0883769400053434 · Cited by 9
La biopile enzymatique à glucose/oxygène
Alcaraz, J., Ichi, S. E., Cortella, L., Guimier-Pingault, C., Zebda, A., Cinquin, P., & Martin, D. K. (2016) · médecine/sciences · doi:10.1051/medsci/20163208027 · Cited by 9
Self-citationNewly available and recent advances in drug-eluting stents
Costopoulos, C., Latib, A., Naganuma, T., Sticchi, A., Giannini, F., & Colombo, A. (2013) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.13.43 · Cited by 8
Environmental Enrichment: A Cure for Cancer? It's All in the Mind
Pang, T. Y., & Hannan, A. J. (2010) · Journal of Molecular Cell Biology · doi:10.1093/jmcb/mjq027 · Cited by 6
Teotia, R. S., Dahe, G. J., & Bellare, J. R. (2014) · Advanced Science Letters · doi:10.1166/asl.2014.5496 · Cited by 6
Lanmüller, H., Saucrmann, S., Unger, E., Mayr, W., & Zrunek, M. (1999) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1999.44.5.114 · Cited by 5
A simple remote-controlled power switch for internalized bioelectronic instrumentation
Varosi, S. M., Brigmon, R. L., & Besche, E. L. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.30813 · Cited by 3
Implantable Cardioverter-Defibrillators
Saksena, S. V., & Madan, N. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00086-7 · Cited by 2
Research works printed but not linked: 3
- Li, 1990, Lithium iodine batteries used in pacemaker, Chin. J. Power Sourc., 1, 5
- Giner, 1973, Eine implantierbare Brennstoffzelle zum Betrieb eines mechanischen Herzens Berichte der Bunsen-Gesellchaft, Phys. Chem., 77
- Pankratov, 2014, Self-charging electrochemical biocapacitor, ChemElectroChem, 1, 343, 10.1002/celc.201300142 · DOI
Cited by
Sorted by citations
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 940
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, É., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 520
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, N. S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 510
Self-citationApplications of nanotechnology in smart textile industry: A critical review
Shah, M. A., Pirzada, B. M., Price, G. J., Shibiru, A. L., & Qurashi, A. (2022) · Journal of Advanced Research · doi:10.1016/j.jare.2022.01.008 · Cited by 438
Application of nanoparticles in biofuels: An overview
Sekoai, P. T., Ouma, C. N. M., du Preez, S. P., Modisha, P. M., Engelbrecht, N., Bessarabov, D., & Ghimire, A. (2018) · Fuel · doi:10.1016/j.fuel.2018.10.030 · Cited by 393
Metadata
- Authors
- Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Queen Mary University of London (GB)
- Malmö University (SE)
- University of Utah (US)
- Corresponding author
- Martin, Donald K.
- ORCID
- Venue
- Bioelectrochemistry
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 124
- Pages
- 57-72
- ISSN
- 1567-5394 (ISSN-L)
- OpenAlex
- W2808838311
- Cited by
- 224
- References
- 127
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 23 · 2023: 33 · 2022: 29 · 2021: 44 · 2020: 32 · 2019: 25 · 2018: 6
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Bioelectrochemistry (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by-nc-nd)
- KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
- Malmö University Publications (Malmö University) (submittedVersion)
- Queen Mary Research Online (Queen Mary University of London) (submittedVersion, cc-by)
- Funders
- Vetenskapsrådet (621-2013-6006)
- Engineering and Physical Sciences Research Council (EP/H009744/1)
- Agence Nationale de la Recherche (ANR-15-CE05-0003-01)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Keywords
- implantable biofuel cells, biocompatibility, biofouling, biomedical implants, ethical considerations, long-term implantation
- MeSH terms
- Animals, Biocompatible Materials, Bioelectric Energy Sources, Electrodes, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review