The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces
Open accessAbstract
Atomic force microscopy (AFM) was used to directly measure the adhesion forces between three test proteins and low density polyethylene (LDPE) surfaces treated by glow discharge plasma to yield various levels of water wettability. The adhesion of proteins to the LDPE substrates showed a step dependence on the wettability of surfaces as measured by the water contact angle (theta). For LDPE surfaces with theta> approximately 60-65 degrees , stronger adhesion forces were observed for bovine serum albumin, fibrinogen and human FXII than for the surfaces with theta<60 degrees . Smaller adhesion forces were observed for FXII than for the other two proteins on all surfaces although trends were identical. Increasing the contact time from 0 to 50s for each protein-surface combination increased the adhesion force regardless of surface wettability. Time varying adhesion data was fit to an exponential model and free energies of protein unfolding were calculated. This data, viewed in light of previously published studies, suggests a 2-step model of protein denaturation, an early stage on the order of seconds to minutes where the outer surface of the protein interacts with the substrate and a second stage involving movement of hydrophobic amino acids from the protein core to the protein/surface interface. Impact statement: The work described in this manuscript shows a stark transition between protein adherent and protein non-adherent materials in the range of water contact angles 60-65 degrees , consistent with known changes in protein adsorption and activity. Time-dependent changes in adhesion force were used to calculate unfolding energies relating to protein-surface interactions. This analysis provides justification for a 2-step model of protein denaturation on surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Albeit it is most prominently active in the earlier stages where it affects platelet accumulation, coagulation, protein adsorption, and cell adhesion,[ 156 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [156]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This process—known as the Vroman effect—can vary in protein composition and time course for different implanted materials, leading to differences in FBR across different materials even at this early stage (Wilson et al., 2005; Xu and Siedlecki, 2007).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Xu and Siedlecki, 2007
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“As previously indicated, these adsorbed proteins may desorb rapidly, i.e. the Vroman Effect, and thus present time-dependent variations in the type and level of proteins cells encounter in the in vivo environment.[15]”
From Foreign body reaction to biomaterials (2008) · cites this paper as [15]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Interpretation of Protein Adsorption: Surface-Induced Conformational Changes
Roach, P., Farrar, D. F., & Perry, C. C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042898o · Cited by 1,487
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Role of hydration and water structure in biological and colloidal interactions
Israelachvili, J. N., & Wennerström, H. (1996) · Nature · doi:10.1038/379219a0 · Cited by 1,371
Biomedical surface science: Foundations to frontiers
Castner, D. G., & Ratner, B. D. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01587-4 · Cited by 1,329
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 892
Globular proteins at solid/liquid interfaces
Haynes, C. A., & Norde, W. (1994) · Colloids and Surfaces B Biointerfaces · doi:10.1016/0927-7765(94)80066-9 · Cited by 849
Effect of Surface Wettability on the Adsorption of Proteins and Detergents
Sigal, G. B., Mrksich, M., & Whitesides, G. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja970819l · Cited by 817
Faucheux, N., Schweiss, R., Lützow, K., Werner, C., & Groth, T. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.069 · Cited by 743
FTIR/ATR for protein adsorption to biomaterial surfaces
Chittur, K. K. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00223-8 · Cited by 406
Cited by
Sorted by citations
Items 401–500 of 714
Haraguchi, K., Takehisa, T., Mizuno, T., & Kubota, K. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00079 · Cited by 12
Transferred plasma jet as a tool to improve the wettability of inner surfaces of polymer tubes
Prysiazhnyi, V., Saturnino, V. F. B., & Kostov, K. G. (2017) · International Journal of Polymer Analysis and Characterization · doi:10.1080/1023666x.2016.1277053 · Cited by 12
Surface Integrity and Biological Response of Ti-Alloy Implants after Surface Modification
Singh, V., Katyal, P., Kumar, K., & Kumar, R. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.08.235 · Cited by 12
BSA/HSA ratio modulates the properties of Ca2+-induced cold gelation scaffolds
Ribeiro, A., Volkov, V., Oliveira, M. B., Padrão, J., Mano, J. F., Gomes, A. C., & Cavaco-Paulo, A. M. (2016) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2016.05.012 · Cited by 12
Abdullah, A., Shakibania, S., Patel, T., Shyntum, D. Y., & Krukiewicz, K. (2024) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.4c05458 · Cited by 11
Rutile facet-dependent fibrinogen conformation: Why crystallographic orientation matters
Struczyńska, M., Firkowska‐Boden, I., Scheuer, K., & Jandt, K. D. (2022) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2022.112506 · Cited by 11
Pernari, J., & Wells, L. A. (2023) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37537 · Cited by 11
Anderson, J. M., & Patel, J. D. (2012) · Springer eBooks · doi:10.1007/978-1-4614-1031-7_6 · Cited by 11
Lee, J. Y., Lee, H., Kim, Y. B., & Kim, G. (2014) · Plasma Processes and Polymers · doi:10.1002/ppap.201400076 · Cited by 11
Micropatterned surfaces with controlled ligand tethering
Petrie, T. A., Stanley, B. T., & Garcı́a, A. J. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32140 · Cited by 11
Sheikholeslami, Z. S., Yousefi, M., Imani, M., & Joupari, M. D. (2017) · Journal of Materials Science · doi:10.1007/s10853-017-1590-8 · Cited by 11
Switchable and Obedient Interfacial Properties That Grant New Biomedical Applications
Esmaeilzadeh, P., & Groth, T. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b06253 · Cited by 11
Wargenau, A., Fekete, N., Béland, A. V., Sabbatier, G., Bowden, O. M., Boulanger, M. D., & Hoesli, C. A. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.110447 · Cited by 11
Imbir, G., Mzyk, A., Trembecka‐Wójciga, K., Jasek-Gajda, E., Plutecka, H., Schirhagl, R., & Major, R. (2020) · Nanomaterials · doi:10.3390/nano10050859 · Cited by 11
Jasmine, S., Thangavelu, A., Krishnamoorthy, R., Alzahrani, K. E., & Alshuniaber, M. A. (2021) · Journal of Microscopy and Ultrastructure · doi:10.4103/jmau.jmau_7_20 · Cited by 13
Lousinian, S., Kalfagiannis, N., & Logothetidis, S. (2009) · Solid State Sciences · doi:10.1016/j.solidstatesciences.2009.05.010 · Cited by 11
Self-driven perfusion culture system using a paper-based double-layered scaffold
Ai, O., Arisaka, Y., & Takeda, N. (2016) · Biofabrication · doi:10.1088/1758-5090/8/3/035010 · Cited by 11
Chung, J. J., Sum, B. S. T., Li, S., Stevens, M. M., Georgiou, T. K., & Jones, J. R. (2017) · Macromolecular Rapid Communications · doi:10.1002/marc.201700168 · Cited by 11
Detsch, R., Will, J., Hum, J., Roether, J. A., & Boccaccini, A. R. (2018) · Learning materials in biosciences · doi:10.1007/978-3-319-74854-2_6 · Cited by 12
Engineering Extracellular Microenvironments: The Impact of Fibrous Materials on Cell Behavior
Lamberger, Z., & Lang, G. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202501942 · Cited by 12
Tortolano, L., Serrano, C., Jubeli, E., Saunier, J., & Yagoubi, N. (2015) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35528 · Cited by 10
Braic, V., Balaceanu, M., Braic, M. T., Vițelaru, C., Titorencu, I. D., Prună, V., Pârău, A. C., Fanara, C., & Vlădescu, A. (2013) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-013-0738-1 · Cited by 10
Chen, L., Tang, Y., Zhao, K., Jiang, X., Zhou, X., & Wu, Z. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.49567 · Cited by 10
Fiaschini, N., Carnevali, F., Esch, S., Vitali, R., Mancuso, M., Sulli, M. M., Diretto, G., Negroni, A., & Rinaldi, A. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16020159 · Cited by 10
Interactions of liposomes with dental restorative materials
Nguyen, S., Adamczak, M., Hiorth, M., Smistad, G., & Kopperud, H. M. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.10.024 · Cited by 10
Гигантские клетки инородных тел и тканевые реакции на поверхности имплантатов
Должиков, А. А., Kolpakov, A. Y., Ярош, А. Л., Молчанова, А. С., & Dolzhikova, I. N. (2017) · Человек и его здоровье · doi:10.21626/vestnik/2017-3/15 · Cited by 10
Hyodo, K., Arisaka, Y., Yamaguchi, S., Yoda, T., & Yui, N. (2019) · Macromolecular Bioscience · doi:10.1002/mabi.201800346 · Cited by 10
Briones, X., Villalobos, V., Queneau, Y., Danna, C. S., Muñoz, R., Rı́os, H. E., Pavez, J., Paez, M. A., Cabrera, R., Tamayo, L., et al. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.109938 · Cited by 10
Werner, R. A., Geier, D., & Becker, T. M. (2020) · Food Engineering Reviews · doi:10.1007/s12393-020-09228-x · Cited by 10
Júnior, A. F., Ribeiro, C. A., Leyva, M. E., Marques, P. S., Soares, C. R. J., & de Queiroz, Á. A. A. (2021) · Journal of Biomaterials Applications · doi:10.1177/08853282211046418 · Cited by 10
Xu, Z., Wang, N., Ma, Y., Dai, H., & Han, B. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.103053 · Cited by 10
Wedler, V., Quinones, D., Peisert, H., & Schäffer, E. (2022) · Chemistry - A European Journal · doi:10.1002/chem.202202036 · Cited by 9
Kim, M., & Kim, G. (2015) · RSC Advances · doi:10.1039/c5ra00915d · Cited by 10
Kajzer, W., Kajzer, A., Grygiel-Pradelok, M., Ziębowicz, A., & Ziębowicz, B. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-39904-1_34 · Cited by 10
Kim, W.-J., Lee, H., Kim, Y., Choi, C. H., Lee, D., Hwang, H., & Kim, G. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/5/055002 · Cited by 10
Burnat, B., Olejarz, P., Batory, D., Cichomski, M., Kaminska, M., & Bociąga, D. (2020) · Coatings · doi:10.3390/coatings10020169 · Cited by 10
Overview on Cell-Biomaterial Interactions
Gonçalves, S., Dourado, F. O. Q., & Rodrigues, L. R. (2014) · Springer eBooks · doi:10.1007/978-3-319-12478-0_4 · Cited by 13
Superior in vivo Compatibility of Hydrophilic Polymer Coated Prosthetic Vascular Grafts
Strang, A. C., Knetsch, M. L. W., Idu, M. M., Bisoendial, R. J., Kramer, G., Speijer, D., Koole, L. H., Stroes, E. S. G., & Rotmans, J. I. (2013) · The Journal of Vascular Access · doi:10.5301/jva.5000166 · Cited by 10
Guzzi, F., Parrotta, E. I., Zaccone, S., Limongi, T., Cuda, G., & Perozziello, G. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822482-3.00005-1 · Cited by 10
Flexible phase change organogel with visualization function for human heat harvesting
Zheng, K., Li, H., Xu, J., Lai, X., Chen, Z., & Zeng, X. (2023) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2023.107540 · Cited by 9
Alenezi, A. (2023) · Surfaces · doi:10.3390/surfaces6030022 · Cited by 9
Early-Stage Protein Adsorption Sequence on Blood-Contacting Surfaces: Answer to Vroman’s Question
Li, Y., Ji, R., Li, Y., Jiang, L., & Chen, H. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c01697 · Cited by 9
Long-term implantable flexible neural interfaces for electrophysiological monitoring
Chen, B., Lu, J., Chen, Z., Han, X., Sun, Y., Lin, X., Tang, Z., Jia, S., Xie, G., Huo, F., et al. (2024) · Journal of Materials Chemistry C · doi:10.1039/d4tc04289a · Cited by 10
Stadlmayr, S., Mautner, A., Bacher, M., Peter, K., Mentler, A., Schulz, S., Lichtenegger, H. C., Brecker, L., Bismarck, A., Naghilou, A., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202415945 · Cited by 9
Song, K. S., Min, T., Jung, J., Shin, D., & Nam, Y. (2016) · Biofouling · doi:10.1080/08927014.2016.1153633 · Cited by 9
Lou, P., Deng, X., & Hou, D. (2023) · Biomedical Materials · doi:10.1088/1748-605x/acb7be · Cited by 9
Ege, D., Pourshahrestani, S., Iorio, F., Reinfelder, H., de Ligny, D., & Boccaccini, A. R. (2023) · Biomedical Materials · doi:10.1088/1748-605x/acf0ad · Cited by 9
Suh, I. W., Kim, J. I., Shrestha, B. K., Jang, S. R., & Park, C. H. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.150757 · Cited by 9
PLA/PCL composites manufactured from commingled yarns for biomedical applications
Pereira-Lobato, C., Echeverry‐Rendón, M., Fernandéz‐Blázquez, J. P., LLorca, J., & González, C. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106819 · Cited by 9
The effect of the foreign body response on drug elution from subdermal delivery systems
Capuani, S., Hernandez, N., Campa‐Carranza, J. N., Trani, N. D., Yoshikawa, T., Farina, M., Joubert, A. L., Caffey, C. A., Simeone, A., Cho, S. W., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123110 · Cited by 10
Ring, A., Langer, S., Tilkorn, D. J., Goertz, O., Henrich, L., Stricker, I., Steinau, H., Steinstraesser, L., & Hauser, J. (2010) · PubMed Central · Cited by 9
Enhanced protein binding on femtosecond laser ablated poly(methyl methacrylate) surfaces
Ma, X., Huo, H., Ming, W., Wang, L., Shen, M., Barry, C. F., & Mead, J. (2011) · Applied Physics Letters · doi:10.1063/1.3583981 · Cited by 9
Protein–polymer interaction: Transfer loading at interfacial region of PES‐based membrane and BSA
Sadegh, H., Sahay, R., & Soni, S. (2019) · Journal of Applied Polymer Science · doi:10.1002/app.47931 · Cited by 9
Cui, J., Yang, Y., Chen, P., Hang, R., Xiao, Y., Liu, X., Zhang, L., Sun, H., & Bai, L. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084212 · Cited by 11
Li, Z., Yang, X., Guo, H., Yang, X., Sun, L., & Dong, S. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-1145-5 · Cited by 9
Properties of Atmospheric Pressure Ar Plasma Jet Depending on Treated Dielectric Material
Prysiazhnyi, V., Castro, A. H. R., & Kostov, K. G. (2016) · Brazilian Journal of Physics · doi:10.1007/s13538-016-0474-8 · Cited by 9
Morro, A., Catalina, F., Pablos, J. L., Corrales, T., Marin, I., & Abrusci, C. (2017) · European Polymer Journal · doi:10.1016/j.eurpolymj.2017.07.027 · Cited by 10
Enhancement of bone to polylactic acid plate bonding by carbonate apatite coating
Zhang, C., Hayashi, K., & Ishikawa, K. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.06.252 · Cited by 9
Cytocompatibility of Si-incorporated TiO2 nanopores films
Shi, Q., & Liu, X. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.06.007 · Cited by 9
Learn, G. D., Lai, E. J., & von Recum, H. A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.01.16.909564 · Cited by 9
Ege, D., Khalili, V., Lu, H., Reinfelder, H., de Ligny, D., & Boccaccini, A. R. (2025) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-025-06863-w · Cited by 8
Dobos, A. M., Ursu, E., Grădinaru, L. M., Dobromir, M., & Filimon, A. (2021) · Membranes · doi:10.3390/membranes11110840 · Cited by 8
Saha, R., Haldar, S., Pradhan, S. S., Jana, K., & Sarkar, K. (2023) · Journal of Materials Chemistry B · doi:10.1039/d2tb02681c · Cited by 8
Protein pattern transfer for biosensor applications
Volcke, C., Gandhiraman, R. P., Basabe‐Desmonts, L., Iacono, M., Gubala, V., Cecchet, F., Cafolla, A. A., & Williams, D. E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.016 · Cited by 8
Major, R., Trembecka‐Wójciga, K., Marcin, K. O. T., Lackner, J. M., Wilczek, P., & Major, B. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.12.013 · Cited by 8
Fabrication and morphological characterization of glass‐ceramic orbital implants
Baino, F., di Confiengo, G. G., & Faga, M. G. (2017) · International Journal of Applied Ceramic Technology · doi:10.1111/ijac.12837 · Cited by 8
de Oliveira, N. K., Miguita, L., Salles, T. H. C., d’Ávila, M. A., Marques, M. M., & Deboni, M. C. Z. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-2621-9 · Cited by 8
Electrospun Biopolyesters: Hydrophobic Scaffolds with Favorable Biological Response
Azari, P., Azari, P., Hosseini, S., Murphy, B. P., & Martinez-Chapa, S. O. (2018) · Journal of Public Health International · doi:10.14302/issn.2641-4538.jphi-18-1975 · Cited by 8
Wang, J., Qing, Y., Xiao, L., Wang, Y. G., Bao, X., Qin, Y., Zhang, J., & Zhang, K. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.125419 · Cited by 8
Kajzer, A., Ceglarska, M., Sura, N., Kajzer, W., BOROWSKI, T., Tarnowski, M., & Pilecki, Z. (2020) · Materials · doi:10.3390/ma13235484 · Cited by 8
Maciąg, F., Moskalewicz, T., Cholewa‐Kowalska, K., Hadzhieva, Z., Dziadek, M., Dubiel, B., Łukaszczyk, A., & Boccaccini, A. R. (2023) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ace9ff · Cited by 8
Abdou, S. M., Moustafa, A., & Allam, N. K. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00196 · Cited by 8
Shen, L.-K., Fan, K.-H., Wu, T.-L., Huang, H., Leung, T., Chen, C., & Chang, W. (2013) · Journal of Polymer Engineering · doi:10.1515/polyeng-2013-0207 · Cited by 8
Microstructural characterization and robust comparison of ceramic porous orbital implants
Baino, F., Labate, G. F. D., di Confiengo, G. G., Faga, M. G., Vitale‐Brovarone, C., & Catapano, G. (2017) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2017.12.047 · Cited by 8
Maruko, Y., Galindo, T. G. P., & Tagaya, M. (2018) · e-Journal of Surface Science and Nanotechnology · doi:10.1380/ejssnt.2018.41 · Cited by 8
Novel materials and therapeutic strategies against the infection of implants
Agarwalla, S. V., Solomon, A. P., Neelakantan, P., & Rosa, V. (2020) · Emergent Materials · doi:10.1007/s42247-020-00117-x · Cited by 8
Plasma Polymer Deposition: A Versatile Tool for Stem Cell Research
MacGregor, M., & Vasilev, K. A. (2016) · Wiley eBooks · doi:10.1002/9781119242642.ch8 · Cited by 8
Fernández, I. A., Haugen, H. J., Nogueira, L. P., López‐Álvarez, M., González, P., López‐Peña, M., González‐Cantalapiedra, A., & Muñoz, F. M. G. (2024) · Materialia · doi:10.1016/j.mtla.2024.102240 · Cited by 7
Nakamura, M., & Yamashita, K. (2025) · Biomaterials Advances · doi:10.1016/j.bioadv.2025.214495 · Cited by 7
Motility of Mytilus galloprovincialis hemocytes: Sensitivity to paracetamol in vitro exposure
Udayan, G., Giordano, M. E., Pagliara, P., & Lionetto, M. G. (2023) · Aquatic Toxicology · doi:10.1016/j.aquatox.2023.106779 · Cited by 7
Hlukhaniuk, A., Świętek, M., Patsula, V., Hodan, J., Janoušková, O., Bystrianský, L., Brož, A., Malić, M., Zasónska, B. A., Tokarz, W., et al. (2024) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35480 · Cited by 7
Laser Surface Processing of Polymers for Biomedical Applications
Waugh, D. G., & Lawrence, J. (2012) · Springer series in materials science · doi:10.1007/978-3-642-28359-8_7 · Cited by 7
Zhou, R., Han, Y. N., Cao, J., Li, M., Jin, G., Luo, H., Zhang, L., & Su, B. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb00709h · Cited by 7
Mukherjee, S., Martı́nez-González, J. Á., & Gowen, A. (2018) · The Analyst · doi:10.1039/c8an01768a · Cited by 7
Surface modification of polyimide film in the barrier discharge for cellular technologies
Kamalov, A., Celujko, K. S., Kolbe, K., Smirnova, N. V., Эдуардовна, Б. М., Bondarenko, P. N., Vaganov, G., Диденко, А. Л., & Yudin, V. E. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2103/1/012051 · Cited by 7
Alwafi, R. (2022) · New Journal of Chemistry · doi:10.1039/d1nj02249k · Cited by 7
Effect of Metal Ions on BSA Adsorption and Tribofilm Formation
Liu, H., Chen, J., Kuang, J., & Yan, Y. J. (2023) · Tribology Letters · doi:10.1007/s11249-023-01721-8 · Cited by 6
Batool, S., Akhtar, M. A., Hussain, Z., & Boccaccini, A. R. (2024) · Ceramics International · doi:10.1016/j.ceramint.2024.03.342 · Cited by 7
Butruk-Raszeja, B. A., Trzaskowski, M., & Ciach, T. (2012) · Chemical and Process Engineering New Frontiers · doi:10.2478/v10176-012-0046-6 · Cited by 7
Svoboda, V., & Liaw, B. Y. (2008) · Pure and Applied Chemistry · doi:10.1351/pac200880112439 · Cited by 7
Sunarintyas, S. (2016) · Advanced structured materials · doi:10.1007/978-3-319-14845-8_5 · Cited by 7
Minimizing Pseudomonas aeruginosa adhesion to titanium surfaces by a plasma nitriding process
Aires, M. D. M., Treter, J., Filho, A. N., Nascimento, I. O., Macêdo, A. J., & Alves, C. (2016) · AIMS Biophysics · doi:10.3934/biophy.2017.1.19 · Cited by 7
Enhancing adhesion and alignment of human gingival fibroblasts on dental implants
Aktas, O. C., Metzger, W., Haidar, A., Açil, Y., Gülses, A., Wiltfang, J., Sacramento, C. M., & Nothdurft, F. P. (2019) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2019.02.004 · Cited by 7
Fukazawa, K., Tsuji, K., Inoue, Y., & Ishihara, K. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.111507 · Cited by 7
Enescu, D., Frache, A., & Geobaldo, F. (2015) · RSC Advances · doi:10.1039/c5ra11283d · Cited by 7
Skrzypiec, M., Weiss, M., Dopierała, K., & Prochaska, K. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110090 · Cited by 7
A Review of the 3D Designing of Scaffolds for Tissue Engineering with a Focus on Keratin ProteinPreprint
Baliga, A., & Borkar, S. (2016) · Preprints.org · doi:10.20944/preprints201609.0091.v1 · Cited by 7
Junge, F., & Haag, R. (2025) · Langmuir · doi:10.1021/acs.langmuir.4c04220 · Cited by 6
Tanfloc-Modified Titanium Surfaces: Optimizing Blood Coagulant Activity and Stem Cell Compatibility
Singh, R. S., Madruga, L. Y. C., Savargaonkar, A. V., Martins, A. F., Kipper, M. J., & Popat, K. C. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c02106 · Cited by 6
Zhang, N., Lu, Y., Li, J., Xiao, Z., Liu, Y., Liu, Y., Wang, Z., Wang, Z., Li, X., Zhang, H., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.07.048 · Cited by 6
Metadata
- Authors
- Xu, L.-C., & Siedlecki, C. A.
- Affiliations
- Pennsylvania State University (US)
- Corresponding author
- Siedlecki, Christopher A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 28
- Issue
- 22
- Pages
- 3273-3283
- ISSN
- 0142-9612 (ISSN-L)
- PMC
- PMC3671914
- OpenAlex
- W1997848759
- Cited by
- 715
- References
- 53
- Citations by year
- 2026: 27 · 2025: 41 · 2024: 42 · 2023: 32 · 2022: 36 · 2021: 46 · 2020: 48 · 2019: 61 · 2018: 41 · 2017: 49 · 2016: 52 · 2015: 38 · 2014: 35 · 2013: 38 · 2012: 28
- FWCI
- 13.06
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Pennsylvania Department of Health
- National Institutes of Health
- Huck Institutes of the Life Sciences
- National Heart, Lung, and Blood Institute (R01HL069965, R01 HL69965)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
- Keywords
- protein adsorption, protein adhesion, wettability, water contact angle, low-density polyethylene, contact time, bovine serum albumin, fibrinogen, biomaterial surfaces
- MeSH terms
- Tissue Adhesions, Adhesiveness, Biocompatible Materials, Blood Coagulation, Cell Adhesion, Fibrinogen, Humans, Protein Denaturation, Proteins, Surface Properties, Wettability, Microscopy, Atomic Force, Polyethylene
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review