Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 582

The DOI matches its Crossref record.

Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery

Open access
Konig, Gerhardt, McAllister, Todd N., Dusserre, Nathalie, Garrido, Sergio A., Iyican, Corey, Marini, Alicia, Fiorillo, Alex, Avila, Hernan, Wystrychowski, Wojciech, Zagalski, Krzysztof, Maruszewski, Marcin, Jones, Alyce Linthurst, Cierpka, Lech, de la Fuente, Luis M., L'Heureux, Nicolas·2009·Biomaterials

Abstract

We have previously reported initial clinical feasibility with our small diameter tissue engineered blood vessel (TEBV). Here we present in vitro results of the mechanical properties of the TEBVs of the first 25 patients enrolled in an arterio-venous (A-V) shunt safety trial, and compare these properties with those of risk-matched human vein and artery. TEBV average burst pressures (3,490 +/− 892 mmHg, n=230) were higher than native saphenous vein (SV) (1,599 +/− 877 mmHg, n=7), and not significantly different than native internal mammary artery (IMA) (3,196 +/− 1,264 mmHg, n=16). Suture retention strength for the TEBVs (152 +/− 50 gmf) was also not significantly different than IMA (138 +/− 50 gmf). Compliance for the TEBVs prior to implantation (3.4 +/− 1.6 %/100 mmHg) was lower than IMA (11.5 +/− 3.9 %/100 mmHg). By 6 months post-implant, the TEBV compliance (8.8 +/− 4.2 %/100 mmHg, n=5) had increased to values comparable to IMA, and showed no evidence of dilation or aneurysm formation. With clinical time points beyond 21 months as an A-V shunt without intervention, the mechanical tests and subsequent lot release criteria reported here would seem appropriate minimum standards for clinical use of tissue engineered vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2008.11.011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 582

Metadata

Authors
Konig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., Maruszewski, M., Jones, A. L., Cierpka, L., de la Fuente, L. M., & L'Heureux, N.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2009-03
Volume
30
Issue
8
Pages
1542-1550
ISSN
0142-9612 (ISSN-L)
OpenAlex
W1981586047
Cited by
582
References
0
FWCI
22.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. https://app.cochat.ai/papers/10.1016/j.biomaterials.2008.11.011
The paper
Konig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., Maruszewski, M., Jones, A. L., Cierpka, L., de la Fuente, L. M., & L'Heureux, N. (2009). Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. Biomaterials. https://doi.org/10.1016/j.biomaterials.2008.11.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.