Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery
Open accessAbstract
We have previously reported initial clinical feasibility with our small diameter tissue engineered blood vessel (TEBV). Here we present in vitro results of the mechanical properties of the TEBVs of the first 25 patients enrolled in an arterio-venous (A-V) shunt safety trial, and compare these properties with those of risk-matched human vein and artery. TEBV average burst pressures (3,490 +/− 892 mmHg, n=230) were higher than native saphenous vein (SV) (1,599 +/− 877 mmHg, n=7), and not significantly different than native internal mammary artery (IMA) (3,196 +/− 1,264 mmHg, n=16). Suture retention strength for the TEBVs (152 +/− 50 gmf) was also not significantly different than IMA (138 +/− 50 gmf). Compliance for the TEBVs prior to implantation (3.4 +/− 1.6 %/100 mmHg) was lower than IMA (11.5 +/− 3.9 %/100 mmHg). By 6 months post-implant, the TEBV compliance (8.8 +/− 4.2 %/100 mmHg, n=5) had increased to values comparable to IMA, and showed no evidence of dilation or aneurysm formation. With clinical time points beyond 21 months as an A-V shunt without intervention, the mechanical tests and subsequent lot release criteria reported here would seem appropriate minimum standards for clinical use of tissue engineered vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vascular Tissue Engineering: Progress, Challenges, and Clinical Promise
Song, H.-H. G., Rumma, R. T., Ozaki, C. K., Edelman, E. R., & Chen, C. S. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.009 · Cited by 476
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
Elloumi‐Hannachi, I., Yamato, M., & Okano, T. (2010) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2009.02185.x · Cited by 271
Syedain, Z. H., Meier, L. A., Bjork, J. W., Lee, A., & Tranquillo, R. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.019 · Cited by 254
Towards organ printing: engineering an intra-organ branched vascular tree
Visconti, R. P., Kasyanov, V., Gentile, C., Zhang, J., Markwald, R. R., & Mironov, V. (2010) · Expert Opinion on Biological Therapy · doi:10.1517/14712590903563352 · Cited by 224
Metadata
- Authors
- Konig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., Maruszewski, M., Jones, A. L., Cierpka, L., de la Fuente, L. M., & L'Heureux, N.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 30
- Issue
- 8
- Pages
- 1542-1550
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1981586047
- Cited by
- 582
- References
- 0
- FWCI
- 22.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. https://app.cochat.ai/papers/10.1016/j.biomaterials.2008.11.011
- The paper
- Konig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., Maruszewski, M., Jones, A. L., Cierpka, L., de la Fuente, L. M., & L'Heureux, N. (2009). Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. Biomaterials. https://doi.org/10.1016/j.biomaterials.2008.11.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.