The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Injectable PLGA based colloidal gels for zero-order dexamethasone release in cranial defects
Open accessAbstract
Bone fillers have emerged as an alternative to the invasive surgery often required to repair skeletal defects. Achieving controlled release from these materials is desired for accelerating healing. Here, oppositely-charged Poly (d,l-lactic-co-glycolic acid) (PLGA) nanoparticles were used to create a cohesive colloidal gel as an injectable drug-loaded filler to promote healing in bone defects. The colloid self-assembled through electrostatic forces resulting in a stable 3-D network that may be extruded or molded to the desired shape. The colloidal gel demonstrated shear-thinning behavior due to the disruption of interparticle interactions as the applied shear force was increased. Once the external force was removed, the cohesive property of the colloidal gel was recovered. Similar reversibility and shear-thinning behavior were also observed in colloidal gels loaded with dexamethasone. Near zero-order dexamethasone release was observed over two months when the drug was encapsulated in PLGA nanoparticles and simply blending the drug with the colloidal gel showed similar kinetics for one month. Surgical placement was facilitated by the pseudoplastic material properties and in vivo observations demonstrated that the PLGA colloidal gels stimulated osteoconductive bone formation in rat cranial bone defects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Three-Dimensional Cell Culture Matrices: State of the Art
Lee, J., Cuddihy, M. J., & Kotov, N. A. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/teb.2007.0150 · Cited by 1,047
Parameters influencing the stealthiness of colloidal drug delivery systems
Vonarbourg, A., Passirani, C., Saulnier, P., & Benoit, J.-P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.039 · Cited by 740
Cited by
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Emerging Frontiers in Drug Delivery
Tibbitt, M. W., Dahlman, J. E., & Langer, R. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b09974 · Cited by 975
Shear-thinning hydrogels for biomedical applications
Guvendiren, M., Lu, H. D., & Burdick, J. A. (2012) · Soft Matter · doi:10.1039/c1sm06513k · Cited by 911
Metadata
- Authors
- Wang, Q., Wang, J., Lu, Q., Detamore, M. S., & Berkland, C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 31
- Issue
- 18
- Pages
- 4980-4986
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1979608886
- Cited by
- 183
- References
- 3
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Injectable PLGA based colloidal gels for zero-order dexamethasone release in cranial defects. https://app.cochat.ai/papers/10.1016/j.biomaterials.2010.02.052
- The paper
- Wang, Q., Wang, J., Lu, Q., Detamore, M. S., & Berkland, C. (2010). Injectable PLGA based colloidal gels for zero-order dexamethasone release in cranial defects. Biomaterials. https://doi.org/10.1016/j.biomaterials.2010.02.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.