Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Gradient nanofibrous chitosan/poly ɛ-caprolactone scaffolds as extracellular microenvironments for vascular tissue engineering

Du, Fengyi, Wang, Hao, Zhao, Wei, Li, Dong, Kong, Deling, Yang, Jun, Zhang, Yuanyuan · 2012 · Biomaterials

Abstract

One of the major challenges of tissue-engineered small-diameter blood vessels is restenosis caused by thrombopoiesis. The goal of this study was to develop a 3D gradient heparinized nanofibrous scaffold, aiding endothelial cells lined on the lumen of blood vessel to prevent thrombosis. The vertical graded chitosan/poly ɛ-caprolactone (CS/PCL) nanofibrous vessel scaffolds were fabricated with chitosan and PCL by sequential quantity grading co-electrospinning. To mimic the natural blood vessel microenvironment, we used heparinization and immobilization of vascular endothelial growth factor (VEGF) in the gradient CS/PCL. The quantity of heparinized chitosan nanofibers increased gradually from the tunica adventitia to the lumen surfaces in the gradient CS/PCL wall of tissue engineered vessel. More heparin reacted to chitosan nanofiber in gradient CS/PCL than in uniform CS/PCL nanofibrous scaffolds. Antithrombogenic properties of the scaffolds were enhanced by the heparinization of these scaffolds, as shown by activated partial thromboplastin time and platelet adhesion assay. Compared to the uniform CS/PCL scaffold, the release of VEGF from the gradient CS/PCL was more stable and sustained, and the burst release of VEGF was reduced approximately 42.5% within the initial 12 h. The adhesion and proliferation of human umbilical vein endothelial cells (HUVEC) were enhanced on the gradient CS/PCL scaffold. Furthermore, HUVEC grew and formed an entire monolayer on the top side of the gradient CS/PCL scaffold. Therefore, use of vertical gradient heparinized CS/PCL nanofibrous scaffolds could provide an approach to create small-diameter blood vessel grafts with innate properties of mammalian vessels of anticoagulation and rapid induction of re-endothelialization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2011.10.037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Du, F., Wang, H., Zhao, W., Li, D., Kong, D., Yang, J., & Zhang, Y.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2012-01
Volume
33
Issue
3
Pages
762-770
ISSN
0142-9612 (ISSN-L)
OpenAlex
W1989331674
Cited by
200
References
2
FWCI
5.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gradient nanofibrous chitosan/poly ɛ-caprolactone scaffolds as extracellular microenvironments for vascular tissue engineering. https://app.cochat.ai/papers/10.1016/j.biomaterials.2011.10.037
The paper
Du, F., Wang, H., Zhao, W., Li, D., Kong, D., Yang, J., & Zhang, Y. (2012). Gradient nanofibrous chitosan/poly ɛ-caprolactone scaffolds as extracellular microenvironments for vascular tissue engineering. Biomaterials. https://doi.org/10.1016/j.biomaterials.2011.10.037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.