The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cartilage-like mechanical properties of poly (ethylene glycol)-diacrylate hydrogels
Open accessAbstract
Hydrogels prepared from poly-(ethylene glycol) (PEG) have been used in a variety of studies of cartilage tissue engineering. Such hydrogels may also be useful as a tunable mechanical material for cartilage repair. Previous studies have characterized the chemical and mechanical properties of PEG-based hydrogels, as modulated by precursor molecular weight and concentration. Cartilage mechanical properties vary substantially, with maturation, with depth from the articular surface, in health and disease, and in compression and tension. We hypothesized that PEG hydrogels could mimic a broad range of the compressive and tensile mechanical properties of articular cartilage. The objective of this study was to characterize the mechanical properties of PEG hydrogels over a broad range and with reference to articular cartilage. In particular, we assessed the effects of PEG precursor molecular weight (508 Da, 3.4 kDa, 6 kDa, and 10 kDa) and concentration (10–40%) on swelling property, equilibrium confined compressive modulus (HA0), compressive dynamic stiffness, and hydraulic permeability (kp0) of PEG hydrogels in static/dynamic confined compression tests, and equilibrium tensile modulus (Eten) in tension tests. As molecular weight of PEG decreased and concentration increased, hydrogels exhibited a decrease in swelling ratio (31.5–2.2), an increase in HA0 (0.01–2.46 MPa) and Eten (0.02–3.5 MPa), an increase in dynamic compressive stiffness (0.055–42.9 MPa), and a decrease in kp0 (1.2 × 10−15 to 8.5 × 10−15 m2/(Pa s)). The frequency-dependence of dynamic compressive stiffness amplitude and phase, as well as the strain-dependence of permeability, were typical of the time- and strain-dependent mechanical behavior of articular cartilage. HA0 and Eten were positively correlated with the final PEG concentration, accounting for swelling. These results indicate that PEG hydrogels can be prepared to mimic many of the static and dynamic mechanical properties of articular cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Cited by
Reinforcement of hydrogels using three-dimensionally printed microfibres
Visser, J., Melchels, F. P. W., Jeon, J. E., van Bussel, E. M., Kimpton, L. S., Byrne, H. M., Dhert, W. J. A., Dalton, P. D., Hutmacher, D. W., & Malda, J. (2015) · Nature Communications · doi:10.1038/ncomms7933 · Cited by 718
Cell-laden hydrogels for osteochondral and cartilage tissue engineering
Yang, J., Zhang, Y. S., Yue, K., & Khademhosseini, A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.036 · Cited by 652
Mondschein, R. J., Kanitkar, A., Williams, C. B., Verbridge, S. S., & Long, T. E. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.005 · Cited by 475
A comparison of different bioinks for 3D bioprinting of fibrocartilage and hyaline cartilage
Daly, A. C., Critchley, S. E., Rencsok, E. M., & Kelly, D. J. (2016) · Biofabrication · doi:10.1088/1758-5090/8/4/045002 · Cited by 436
Recent Advances in Photo-Crosslinkable Hydrogels for Biomedical Applications
Choi, J. R., Yong, K. W., Choi, J. Y., & Cowie, A. C. (2019) · BioTechniques · doi:10.2144/btn-2018-0083 · Cited by 403
Metadata
- Authors
- Nguyen, Q. T., Hwang, Y., Chen, A. C., Varghese, S., & Sah, R. L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2012-10
- Volume
- 33
- Issue
- 28
- Pages
- 6682-6690
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2158961840
- Cited by
- 227
- References
- 1
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cartilage-like mechanical properties of poly (ethylene glycol)-diacrylate hydrogels. https://app.cochat.ai/papers/10.1016/j.biomaterials.2012.06.005
- The paper
- Nguyen, Q. T., Hwang, Y., Chen, A. C., Varghese, S., & Sah, R. L. (2012). Cartilage-like mechanical properties of poly (ethylene glycol)-diacrylate hydrogels. Biomaterials. https://doi.org/10.1016/j.biomaterials.2012.06.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.