The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Conductive PPY/PDLLA conduit for peripheral nerve regeneration
Open accessAbstract
The significant drawbacks and lack of success associated with current methods to treat critically sized nerve defects have led to increased interest in neural tissue engineering. Conducting polymers show great promise due to their electrical properties, and in the case of polypyrrole (PPY), its cell compatibility as well. Thus, the goal of this study is to synthesize a conducting composite nerve conduit with PPY and poly(D, L-lactic acid) (PDLLA), assess its ability to support the differentiation of rat pheochromocytoma 12 (PC12) cells in vitro, and determine its ability to promote nerve regeneration in vivo. Different amounts of PPY (5%, 10%, and 15%) are used to synthesize the conduits resulting in different conductivities (5.65, 10.40, and 15.56 ms/cm, respectively). When PC12 cells are seeded on these conduits and stimulated with 100 mV for 2 h, there is a marked increase in both the percentage of neurite-bearing cells and the median neurite length as the content of PPY increased. More importantly, when the PPY/PDLLA nerve conduit was used to repair a rat sciatic nerve defect it performed similarly to the gold standard autologous graft. These promising results illustrate the potential that this PPY/PDLLA conducting composite conduit has for neural tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Functional Evaluation of Complete Sciatic, Peroneal, and Posterior Tibial Nerve Lesions in the Rat
Bain, J. R., Mackinnon, S. E., & Hunter, D. A. (1989) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198901000-00024 · Cited by 1,260
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Microfabricating Conjugated Polymer Actuators
Jager, E. W. H., Smela, E., & Inganäs, O. (2000) · Science · doi:10.1126/science.290.5496.1540 · Cited by 962
Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Schnell, E., Klinkhammer, K., Balzer, S., Brook, G., Klee, D., Dalton, P., & Mey, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.009 · Cited by 727
Pathophysiology of peripheral nerve injury: a brief review
Burnett, M. G., & Zager, E. L. (2004) · Neurosurgical Focus · doi:10.3171/foc.2004.16.5.2 · Cited by 688
Polypyrrole-based conducting polymers and interactions with biological tissues
Ateh, D. D., Navsaria, H. A., & Vadgama, P. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0141 · Cited by 533
Gurunathan, K., Murugan, A. V., Marimuthu, R., Mulik, U. P., & Amalnerkar, D. P. (1999) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(99)00081-4 · Cited by 481
Peripheral nerve injury: A review and approach to tissue engineered constructs
Evans, G. R. D. (2001) · The Anatomical Record · doi:10.1002/ar.1120 · Cited by 429
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Electrically conductive polymers and composites for biomedical applications
Kaur, G., Adhikari, R., Cass, P., Bown, M., & Gunatillake, P. (2015) · RSC Advances · doi:10.1039/c5ra01851j · Cited by 836
Conducting Polymers for Tissue Engineering
Guo, B., & Ma, P. X. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b00276 · Cited by 835
Self-citationElectrospinning for tissue engineering applications
Rahmati, M., Mills, D. K., Urbanska, A. M., Saeb, M. R., Venugopal, J. R., Ramakrishna, S., & Mozafari, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100721 · Cited by 816
Synthetic biodegradable functional polymers for tissue engineering: a brief review
Guo, B., & Ma, P. X. (2014) · Science China Chemistry · doi:10.1007/s11426-014-5086-y · Cited by 592
Self-citation
Metadata
- Authors
- Xu, H., Holzwarth, J. M., Yan, Y., Xu, P., Zheng, H., Yin, Y., Li, S., & Ma, P. X.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 35
- Issue
- 1
- Pages
- 225-235
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2077406393
- Cited by
- 296
- References
- 28
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conductive PPY/PDLLA conduit for peripheral nerve regeneration. https://app.cochat.ai/papers/10.1016/j.biomaterials.2013.10.002
- The paper
- Xu, H., Holzwarth, J. M., Yan, Y., Xu, P., Zheng, H., Yin, Y., Li, S., & Ma, P. X. (2014). Conductive PPY/PDLLA conduit for peripheral nerve regeneration. Biomaterials. https://doi.org/10.1016/j.biomaterials.2013.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.