CoChat

Fibrillin-2 and Tenascin-C bridge the age gap in lung epithelial regeneration

Open access
Gilpin, Sarah E., Li, Qiyao, Evangelista-Leite, Daniele, Ren, Xi, Reinhardt, Dieter P., Frey, Brian L., Ott, Harald C. · 2017 · Biomaterials
Cited by 63

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Organ engineering based on native matrix scaffolds involves combining regenerative cell populations with corresponding biological matrices to form functional grafts on-demand. The extracellular matrix (ECM) that is retained following lung decellularization provides essential structure and biophysical cues for whole organ regeneration after recellularization. The unique ECM composition in the early post-natal lung, during active alveologenesis, may possess distinct signals that aid in driving cell adhesion, survival, and proliferation. We evaluated the behavior of basal epithelial stem cells (BESCs) isolated from adult human lung tissue, when cultured on acellular ECM derived from neonatal (aged < 1 week) or adult lung donors (n=3 donors per group). A significant difference in cell proliferation and survival was found. We next performed in-depth proteomic analysis of the lung scaffolds to quantify proteins significantly enriched in the neonatal ECM, and identified the glycoproteins Fibrillin-2 (FBN-2) and Tenascin-C (TN-C) as potential mediators of the observed effect. BESCs cultured on Collagen Type IV coated plates, supplemented with FBN-2 and TN-C demonstrated significantly increased proliferation and decreased cellular senescence. No significant increase in epithelial-to-mesenchymal transition was observed. In vitro migration was also increased by FBN-2 and TN-C treatment. Decellularized lung scaffolds treated with FBN-2 and TN-C prior to re-epithelialization supported greater epithelial proliferation and tissue remodeling. BESC distribution, matrix alignment, and overall tissue morphology was improved on treated lung scaffolds, after 3 and 7 days of ex vivo lung culture. These results demonstrate that scaffold re-epithelialization is enhanced on neonatal lung ECM, and that supplementation of FBN-2 and TN-C to the native scaffold may be a valuable tool in lung tissue regeneration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2017.06.027

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Gilpin, S. E., Li, Q., Evangelista-Leite, D., Ren, X., Reinhardt, D. P., Frey, B. L., & Ott, H. C.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2017-09
Volume
140
Pages
212-219
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2713709209
Cited by
63
References
6
FWCI
5.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.